Skip to main content

Advertisement

Log in

Fatal arterial complications following ultrasound-guided attempt of internal jugular vein catheterization

  • Case Report
  • Published:
European Surgery Aims and scope Submit manuscript

Summary

Background

Puncture of the posterior venous wall during ultrasound-guided internal jugular vein cannulation seems to be common, making underlying artery at risk of injury.

Methods

Two cases of injury through the posterior wall of the internal jugular vein and an injury to the underlying artery are reported.

Results

In case number 1, a small injury of the carotid arterial wall resulted in a retrograde dissection of the common carotid artery and ascending part of the aorta, causing a fatal cardiac tamponade—a sequence of events never previously described. In case number 2, an unexpected injury to the thyrocervical trunk in a severely thrombocytopenic patient caused an extensive hematoma that compromised the upper airway, eventually leading to a fatal outcome.

Conclusion

These two reported fatal arterial complications during ultrasound-guided cannulation of the internal jugular vein add to other publications of complications after central vein catheterization. It is important to increase awareness of these avoidable serious complications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Arthur ME, Castresana MR, Paschal JW, et al. Acute cerebellar stroke after inadvertent cannulation and pulmonary artery catheter placement in the right vertebral artery. Anesth Analg. 2006;103(6):1625–6.

    Article  PubMed  Google Scholar 

  2. Wang RC, Katz SE, Lubow M. Visual loss and central venous catheterization: cortical blindness and hemianopsia after inadvertent subclavian artery entry. J Neuroophthalmol. 2000;20(1):32–4.

    Article  PubMed  Google Scholar 

  3. Parsons AJ, Alfa J. Carotid dissection: a complication of internal jugular vein cannulation with the use of ultrasound. Anesth Analg. 2009;109(1):135–6.

    Article  PubMed  Google Scholar 

  4. Inamasu J, Guiot BH. Iatrogenic vertebral artery injury. Acta Neurol Scand. 2005;112(6):349–57.

    Article  PubMed  CAS  Google Scholar 

  5. Polderman KH, Girbes AJ. Central venous catheter use. Part 1: mechanical complications. Intensive Care Med. 2002;28(1):1–17.

    Article  PubMed  Google Scholar 

  6. Rabindranath KS, Kumar E, Shail R, et al. Use of real-time ultrasound guidance for the placement of hemodialysis catheters: a systematic review and meta-analysis of randomized controlled trials. Am J Kidney Dis. 2011;58(6):964–70.

    Article  PubMed  Google Scholar 

  7. Moon CH, Blehar D, Shear MA, et al. Incidence of posterior vessel wall puncture during ultrasound-guided vessel cannulation in a simulated model. Acad Emerg Med. 2010;17(10):1138–41.

    Article  PubMed  Google Scholar 

  8. Hamilton DL, Jackson RM. Haemopericardium: a rare fatal complication of attempted subclavian vein cannulation. A report of two cases. Eur J Anaesthesiol. 1998;15(4):501–4.

    PubMed  CAS  Google Scholar 

  9. Barton JJ, Vanecko R, Gross M. Perforation of right atrium and resultant cardiac tamponade: a complication of catheterization to measure central venous pressure. Obstet Gynecol. 1968;32(4):556–60.

    PubMed  CAS  Google Scholar 

  10. Chabanier A, Dany F, Brutus P, et al. Iatrogenic cardiac tamponade after central venous catheter. Clin Cardiol. 1988;11(2):91–9.

    Article  PubMed  CAS  Google Scholar 

  11. Fangio P, Mourgeon E, Romelaer A, et al. Aortic injury and cardiac tamponade as a complication of subclavian venous catheterization. Anesthesiology. 2002;96(6):1520–2.

    Article  PubMed  Google Scholar 

  12. Shrikhande GV, Khan SZ, Meltzer AJ, et al. Endovascular management of type B aortic dissection after attempted central venous catheterization. Ann Vasc Surg. 2011;25(7):979, e13–5.

    Article  PubMed  Google Scholar 

Download references

Conflict of interest

The authors declare that there is no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Pikwer MD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pikwer, A., Krantz, P., Resch, T. et al. Fatal arterial complications following ultrasound-guided attempt of internal jugular vein catheterization. Eur Surg 45, 179–183 (2013). https://doi.org/10.1007/s10353-013-0193-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10353-013-0193-0

Keywords

Navigation