Extensive peristomal skin necrosis is an unusual complication, which is difficult to manage because of frequent contamination from the stoma site. This wound leads to difficulty in applying the stoma appliance. This case report describes the successful use of the vacuum-assisted closure system in the management of a patient who developed peristomal skin necrosis after emergency Hartmann’s procedure.
References
Rolstad BS, Erwin-Toth PL. Peristomal skin complications: prevention and management. Ostomy Wound Manage 2004;50:68–77.
Ljung T, Staun M, Grove O, Fausa O, Vatn MH, Hellstrom PM. Pyoderma gangrenosum associated with crohn disease: effect of TNF-alpha blockade with infliximab. Scand J Gastroenterol 2002;37:1108–10.
Venturi ML, Attinger CE, Mesbahi AN, Hess CL, Graw KS. Mechanisms and clinical applications of the vacuum-assisted closure (VAC) device: a review. Am J Clin Dermatol 2005;6:185–94.
Moues CM, van den Bemd GJ, Meerding WJ, Hovius SE. An economic evaluation of the use of TNP on full-thickness wounds. J Wound Care 2005;14:224–7.
Shellito PC. Complications of abdominal stoma surgery. Dis Colon Rectum 1998;41:1562–72.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Yoong, S., Dunne, G., Cochrane, J. et al. Vacuum-Assisted Closure for the Treatment of Parastomal Skin Necrosis: A Novel Approach to an Unusual Complication. Report of a Case. Dis Colon Rectum 51, 1577–1579 (2008). https://doi.org/10.1007/s10350-008-9240-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10350-008-9240-5