Abstract
A novel polyphenyl-grafted polysiloxane stationary phase named 3,4-bis(2-fluoro-5-(trifluoromethyl)phenyl)-2,5-diphenyl phenyl grafted polysiloxane stationary phase (FFMP) was synthesized through a Diels–Alder reaction with a high column efficiency (average number of plates: 3700 plates/m; achieved by naphthalene at 120 °C) and simultaneously coated on fused silica capillary tubes to prepare a gas chromatographic column with excellent performance. The column performance test results indicated that the FFMP columns could work properly up to 360 °C, as evidenced by the chromatogram of the polyethylene pyrolysis mixture. The thermogravimetric analysis curve showed that the decomposition temperature of the FFMP was up to 380 °C. The FFMP columns were also applied in the separation and analysis of multimixtures, such as Grob test mixtures, benzene mixtures and fatty acid esters, and as well as a medium polar stationary phase (according to the results of McReynolds constants, the sum of ∆I was 779.) The FFMF columns exhibited excellent separation selectivity for these substances because of the conjugated system formed by the polyphenyl side chain connected by single bonds. This conjugated system can promote the delocalization of π-electrons as well as enhance the forces of π–π interaction, and the dipole-induced dipole action between the FFMP stationary phase and the analytes.







Similar content being viewed by others
Explore related subjects
Discover the latest articles and news from researchers in related subjects, suggested using machine learning.References
Ruo-Nong FU (2006) Evolution of gas chromatographic stationary phases. Chem Reag 28:11–15
Chen B, Liang C, Yang J, Contreras DS (2006) A microporous metal-organic framework for gas-chromatographic separation of alkanes. J Angew Chem Int Ed 118:1418–1421
Gu ZY, Yan XP (2010) Metal–organic framework MIL-101 for high resolution gas chromatographic separation of xylene isomers and ethylbenzene. J Angew Chem Int Ed 49:1477–1480
Chang N, Gu ZY, Yan XP (2010) Zeolitic imidazolate framework-8 nanocrystal coated capillary for molecular sieving of branched alkanes from linear alkanes along with high-resolution chromatographic separation of linear alkanes. J Am Chem Soc 132:13645–13647
Chang N, Yan XP (2012) Exploring reverse shape selectivity and molecular sieving effect of metal-organic framework UIO-66 coated capillary column for gas chromatographic separation. J Chromatogr A 1257:116–124
Xie SM, Zhang ZJ, Wang ZY, Yuan LM (2011) Chiral metal-organic frameworks for high resolution gas chromatographic separations. J Am Chem Soc 133:11892–11895
Gu ZY, Jiang JQ, Yan XP (2011) Fabrication of isoreticular metal–organic framework coated capillary columns for high-resolution gas chromatographic separation of persistent organic pollutants. J Anal Chem 83:5093–5100
Saridara C, Mitra S (2005) Chromatography on self-assembled carbon nanotubes. J Anal Chem 77:7094–7097
Karwa M, Mitra S (2006) Gas chromatography on self-assembled, single-walled carbon nanotubes. J Anal Chem 78:2064–2070
Gopalan AI, Lee KP, Ragupathy D (2009) Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network. J Biosens Bioelectron 24:2211–2217
Wasserscheid P, Bosmann A, Bolm C (2002) Synthesis and properties of ionic liquids derived from the chiral pool. J Chem Commun 25:200–201
Xiaoqi L, Yangliao Hu, Yaqing Fu (2012) Synthesis and characterization of Lu (111) ion imprinted polymer. J Inorg Organomet Polym 22:112–118
Kuei JC, Shelton JI, Castle LW (2015) Polarizable biphenyl polysiloxane stationary phase for capillary column gas chromatography. J Sep Sci 7:13–18
Haken JK (1977) Polysiloxane stationary phases in gas chromatography. J Chromatogr A 141:247–288
Ahnoff M, Johansson L (1984) Preparation and evaluation of capillary columns with phases with 5–33% phenyl substitution. J Chromatogr 19:151–154
Stark TJ, Larson PA, Dandeneau RD (1983) Selective phases for wall-coated open tubular columns. J Chromatogr A 279:31–40
Peaden PA, Wright BW, Lee ML (1982) The preparation of non-extractable methylphenylpolysiloxane stationary phases for capillary column gas chromatography. J Chromatogr 15:335–340
Bradshaw JS, Crowley SJ, Harper CW (2015) Autocrosslinkable methyl-2-phenylethylpoly-siloxane stationary phase for capillary column gas chromatography. J Sep Sci 7:89–92
Bradshaw JS, Adams NW, Johnson RS (2015) Preparation of polysiloxane stationary phases for capillary column chromatography: a new methoxyphenyl phase. J Sep Sci 8:678–683
Mayer BX, Kählig H, Rauter W (2003) A 50% n-octylmethyl, 50% diphenyl-polysiloxane as stationary phase with unique selectivity for gas chromatography. J Analyst 128:1238
Mayer BX, Rauter W, Kählig H (2015) A trifluoropropyl-containing silphenylene-siloxane terpolymer for high temperature gas chromatography. J Sep Sci 26:1436–1442
Santos FJ, Galceran MT (2002) The application of gas chromatography to environmental analysis. J Trends Anal Chem 21:672–685
Zuazagoitia D, Millán E, Garciaarrona R (2007) A screening method for polycyclic aromatic hydrocarbons determination in sediments by headspace SPME with GC-FID. J Chromatogr 66:773–777
Zhao P, Teng S, Yu M (2014) Synthesis and characterization of diphenyl-phenyl polysiloxane as a high-temperature gas chromatography stationary phase. J Anal Methods 7:1333–1338
Han X, He X, Wang H (2016) Fluoro-substituted tetraphenyl-phenyl grafted polysiloxanes as highly selective stationary phases for gas chromatography. J Chromatogr A 1449:118–128
Zhao PC, Liu L, Yu M, Niu N (2015) A 3,4-2 (trifluoromethyl phenyl)-2,5-diphenyl phenyl grafted polysiloxane as a stationary phase for gas chromatography. J Anal Methods 6278–6284
Miller KJ, Savchik J (1979) A new empirical method to calculate average molecular polarizabilities. J Am Chem Soc 101:7206–7213
Grob JK, Grob G, Grob K (1978) Comprehensive, standardized quality test for glass capillary columns. J Chromatogr A 156:1–20
Zhao PC, Niu YY, Yu M, Niu N, Wang H (2015) High temperature stationary phase of polysiloxane containing N, N′-bis (diphenylsilyl) tetramethylcyclodisilazane for gas chromatography. J RSC Adv 5:22399–22404
He X, Han X, Wang H (2016) Polysiloxanes-based stationary phases containing methoxy-substituted tetraphenyl–phenyl groups for gas chromotographic separations. J Rsc Adv 6:76514–76523
Friedman W, Gugig, Mehr L (1959) The synthesis of some alkoxy- and alkyl-substituted tetraphenylcyclopentadienones. J OrgChem 24:516–520
Feng SY, Zhang J, Li MJ, Zhu QZ (2004) Silicone polymers and their applications. Chemical Industry Press, Beijing, pp 79–80
Wang L, Wang X, Qi M et al (2014) Cucurbit [6]uril in combination with guanidinium ionic liquid as a new type of stationary phase for capillary gas chromatography. J Chromatogr A 1334:112–117
Thomas TH, Kendrick TC (2003) Thermal analysis of polysiloxanes. II. Thermal vacuum degradation of polysiloxanes with different substituents on silicon and in the main siloxane chain. J Polym Sci Part B Polym Phys 8:1823–1830
Grob K, Grob G (1981) Evaluation of capillary columns by separation number or plate number. J Chromatogr 207:291–297
Poole CF, Poole (2008) S K. Separation characteristics of wall-coated open-tubular columns for gas chromatography. J Chromatogr A 1184:254–280
Abraham MH, Poole CF, Poole SK (1999) Classification of stationary phases and other materials by gas chromatography. J Chromatogr 842:79–114
Zheng T, Luo Y, Cao X (2006) Advances in research of microbial degradation of high molecular weight polycyclic aromatic hydrocarbons-benzo(a)pyrene. J Appl Environ Biol 12:884–890
Wang XG, Qi ML, Fu RN (2014) Separation performance of cucurbit[7]uril in ionic liquid-based sol-gel coating as stationary phase for capillary gas chromatography. J Chromatogr A 1371:237–243
Acknowledgements
This study was supported by the National Natural Science Foundation of China (No. 21275090).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Wang, B., Liu, J., Li, X. et al. Synthesis and Applications of a Novel 3,4-Bis(2-Fluoro-5-Trifluoromethyl Phenyl)-2,5-Diphenyl Phenyl Grafted Polysiloxane Stationary Phase. Chromatographia 81, 1219–1229 (2018). https://doi.org/10.1007/s10337-018-3556-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10337-018-3556-7