Abstract
The retention behavior of inorganic anions was investigated on a hydrophobic stationary phase dynamically modified with 18-crown-6 ether (18C6) in capillary ion chromatography. Styrene–divinylbenzene copolymeric (polystyrene) packing material was used as the hydrophobic stationary phase to retain 18C6. The eluent contained 18C6, salt and acetonitrile; 18C6 was retained on the stationary phase and the analytes anions were separated by the cations, which were trapped on the 18C6 and worked as the anion-exchange sites. The effect of eluent conditions, such as eluent cation species, acetonitrile (ACN), 18C6, and salt concentrations (in this case, potassium chloride was used), was investigated. The retention times of inorganic anions decreased with increasing concentration of ACN. In case ACN concentration was less than 4%, the retention times decreased with the passage of time. The retention time of inorganic anions increased with increasing concentrations of 18C6 and potassium chloride concentrations. By contrast, high concentration of 18C6 and chloride in eluent promotes elution of inorganic anions, and the retention time decreased. Furthermore, a contactless conductivity detector was used to replace the conventional UV detector to obtain higher sensitivity detection. Separation of inorganic anions was achieved with the eluent containing potassium hydroxide and enhanced peak intensity was observed using a suppressed contactless conductivity detection.
Graphical abstract








References
Rey MA, Pohl CA, Jagodzinski JJ, Kaiser EQ, Riviello JM (1998) J Chromatogr A 804:201–209
Ohta K, Tanaka K (1999) Analyst 124:505–510
Pohl C, Rey M, Jensen D, Kerth J (1999) J Chromatogr A 850:239–245
Richens DA, Simpson D, Peterson S, McGinn A, Lamb JD (2003) J Chromatogr A 1016:155–164
Ohta K, Morikawa H, Tanaka K (1999) J Chromatogr A 850:229–238
Ohta K, Tanaka K (1999) Anal Chim Acta 381:265–273
Ohta K (2000) J Chromatogr A 884:113–122
Läubli MW, Kampus B (1995) J Chromatogr A 706:103–107
Dumont PJ, Fritz JS (1995) J Chromatogr A 706:149–158
Kwon S, Lee K, Tanaka K, Ohta K (1999) J Chromatogr A 850:79–84
Takayanagi T, Ikeda I, Motomizu S (2001) J Chromatogr A 932:165–170
Takeuchi T, Lim LW (2011) Anal Sci 27:1019–1023
Lamb JD, Smith RG, Jagodzinski J (1993) J Chromatogr 640:33–40
Igawa M, Saito K, Tsukamoto J, Tanaka M (1981) Anal Chem 53:1942–1944
Edwards BR, Giauque AP, Lamb JD (1995) J Chromatogr A 706:69–79
Yokoyama T, Okuda Y, Kohara K, Zenki M (1996) J Chromatogr A 755:43–48
Iwachido T, Naito H, Samukawa F, Ishimaru K, Toei K (1986) Bull Chem Soc Jpn 59:1475–1480
Saari-Nordhaus R, Anderson JM Jr (2004) J Chromatogr A 1039:123–127
Nakajima M, Kimura K, Shono T (1983) Bull Chem Soc Jpn 56:3052–3056
Lim LW, Tokunaga K, Takeuchi T (2014) Chromatography 35:95–101
Takeuchi T, Tokunaga K, Lim LW (2013) Anal Sci 29:423–427
Nagae N, Enami T (2000) Bunseki Kagaku 49(11):887–894
Hiraoka M (1982) CROWN COMPOUNDS their characteristics and applications, studies in organic chemistry, vol 12. Elsevier Scientific Publishing, Amsterdam
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Funding
This study was partially funded by the Japan Society for the Promotion of Science (JSPS KAKENHI Grant Numbers JP25810085 and JP15K05536).
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Rights and permissions
About this article
Cite this article
Kawase, I., Lim, L.W. & Takeuchi, T. Capillary Ion Chromatography Using 18-Crown-6 Ether as Eluent Additive for the Separation of Anions. Chromatographia 80, 1089–1093 (2017). https://doi.org/10.1007/s10337-017-3311-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10337-017-3311-5