Abstract
Methanol and ethanol in transformer oils have been recently proposed as new markers of thermal and mechanical degradation of cellulose (the solid insulation in power transformers). In this work, we optimized and compared the performance of two headspace gas chromatographic methods based on flame ionization (HS–GC–FID) and mass spectrometry detection (HS–GC–MS) to determine methanol and ethanol in insulating mineral oil. For methanol and ethanol, the detection limits were 12 and 27 μg kg−1 (HS–GC–FID) and 1.3 and 3.1 μg kg−1 (HS–GC–MS). Repeatability was evaluated in transformer oils for both the methods at different concentration levels of analytes and RSD values were found to lie between 1.8 and 16 %. The accuracy of the methods was assessed under a proficiency test (Cigré JWG A2/D1.46). The methods were compared by a F-test and a one-sided paired t test performed on 21 transformer oils in service. Correlations of methanol and ethanol content in sampled oils against their actual time of service are provided. For each sample, the content of traditional markers (furan-2-carbaldehyde and CO2) was also measured, finding a correlation between light alcohols and CO2 content. This indicates that methanol and ethanol determination may be helpful in providing further information on the thermal degradation conditions of transformers’ solid insulation. The method developed is currently routinely applied by the laboratories of Sea Marconi Technologies for the assessment of transformers’ conditions.






Similar content being viewed by others
Explore related subjects
Discover the latest articles and news from researchers in related subjects, suggested using machine learning.References
De Carlo RM, Sarzanini C, Bruzzoniti MC, Maina R, Tumiatti V (2014) Copper-in-oil dissolution and copper-on-paper deposition behavior of mineral insulating oils. IEEE Trans Dielectr Electr Insul 21:666–673
Tamura R, Anetai H, Ishii T, Kawamura T (1981) The diagnostics of the ageing deteriora-tion of insulating paper in transformer by gas analysis. JIEE Proc Pub. A 101:30–36
Burton PJ, Graham J, Hall AC, Laver JA, Oliver AJ (1984) Recent developments by CEGB to improve the prediction and monitoring of transformer performance. CIGRE Conf., Paper 12–09
Lessard MC et al (2012) Furanic compounds for diagnosis. CIGRÉ Working Group D1.01(TF13), CIGRÉ Technical Brochure 494
Jalbert J, Gilbert R, Tétreault P, Morin B, Lessard-Déziel D (2007) Identification of a chemical indicator of the rupture of 1, 4-b-glycosidic bonds of cellulose in an oil-impregnated insulating paper system. Cellulose 14:295–309
Mittelbach M, Roth G, Bergmann A (1996) Simultaneous gas chromatographic determination of methanol and free glycerol in biodiesel. Chromatographia 42:431–434
Knothe G (2006) Analyzing biodiesel: standards and other methods. J Am Oil Chem Soc 83:823–833
Faber Boog JH, Cardoso Silveira EL, Basílio de Caland L, Tubino M (2011) Determining the residual alcohol in biodiesel through its flash point. Fuel 90:905–907
Annual Book of ASTM Standards (2013) Petroleum Products and Lubricants (IV): D7059-09. 05.04, Conshohocken, PA
Mokhtari B, Pourabdollah K (2012) Determination of hydrate inhibitor in crude oil by nanoextraction–gas chromatography. J Sep Sci 35:79–85
Jalbert J, Duchesne S, Rodriguez-Celis E, Tétreault P, Collin P (2012) Robust and sensitive analysis of methanol and ethanol from cellulose degradation in mineral oils. J Chrom A 1256:240–245
International Electrotechnical Commission (IEC) (2005) Oil-filled electrical equipment—Sampling of gases and of oil for analysis of free and dissolved gases—Guidance 60567
International Electrotechnical Commission (IEC) (1993) Mineral insulating oils—Methods for the determination of 2-furfural and related compounds—Guidance 61198
United States Environmental Protection Agency (US EPA) (2004) Revised assessment of detection and quantitation approaches. Chapter 5.1: Detection Limit Approaches, EPA-821-B-04-005, Washington, DC
United States Environmental Protection Agency (US EPA) (2004) Definition and Procedure for the Determination of the Method Detection Limit. Revision 1.11, 40CFR-Part 136, Appendix B
IEC International Electrotechnical Commission (1999) Mineral oil-impregnated electrical equipment in service—Guide to the interpretation of dissolved and free gases analysis—Guidance 60599 ed 2.0
Acknowledgments
The authors would like to thank Drs. Giorgio Rocchia and Luca Rivoira for their valuable help. Financial support from MIUR (Ministero dell’Istruzione, dell’Università e della Ricerca, Italy) is gratefully acknowledged. Financial support from Compagnia di San Paolo and University of Torino (Progetto d’Ateneo 2012) is also acknowledged.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published in the special paper collection of the 19th International Symposium on Separation Sciences with guest editors Tomislav Bolanča and Bogusław Buszewski.
Rights and permissions
About this article
Cite this article
Bruzzoniti, M.C., Maina, R., De Carlo, R.M. et al. GC Methods for the Determination of Methanol and Ethanol in Insulating Mineral Oils as Markers of Cellulose Degradation in Power Transformers. Chromatographia 77, 1081–1089 (2014). https://doi.org/10.1007/s10337-014-2650-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10337-014-2650-8

