Abstract
A single-drop microextraction (SDME) procedure with a modified microsyringe was developed for the analysis of six organophosphorus pesticides (OPPs) in water. Microsyringe was modified by attaching a 2-mm cone onto the needle tip end. The conditions affecting SDME performance including microextraction solvent, stirring speed, extraction time, ionic strength and sample pH were optimized. Under the optimized conditions, the linear ranges of the SDME with ethion as internal standard were 0.05–50 μg L−1 (except for dimethoate 5–5,000 μg L−1) and limits of detection (LOD) were 0.012–0.020 μg L−1 (except for dimethoate 0.45 μg L−1). Recoveries of six pesticides were in the range of 70.6–107.5 % with relative standard deviation lower than 6.0 %. The modified method is simple, rapid and sensitive, and acceptable in the analysis of OPPs pesticides in water samples.
Similar content being viewed by others
References
Liu WM, Hu Y, Zhao JH, Xu Y, Guan YF (2005) J Chromatogr A 1095:1–7
Zhao EC, Zhao WT, Han LJ, Jiang SR, Zhou ZQ (2007) J Chromatogr A 1175:137–140
Zhang YH, Liu SS, Song XQ, Ge HL (2008) Ecotox Environ Safe 71:880–888
Cortada C, Vidal L, Tejada S, Romo A, Canals A (2009) Anal Chim Acta 638:29–35
Zhao FQ, Lu S, Du W, Zeng BZ (2009) Microchim Acta 165:29–33
Saraji M, Mirmahdieh S (2009) J Sep Sci 32:988–995
González-Curbelo MÁ, Asensio-Ramos M, Herrera–Herrera AV, Hernández-Borges J (2012) Anal Bioanal Chem 404:183–196
Moussavi G, Hosseini H, Alahabadi A (2013) Chem Eng J 214:172–179
Nam JW, Lee KJ, Myung SW (2012) J Korean Chem Soc 56:583–590
Sivagami K, Krishna RR, Swaminathan T (2013) J Water Sustain 3:143–151
Zhao LM, Schultz D, Stevens J (2012) Agilent technologies. http://www.agilent.com/chem/cn. Accessed 6 Jan 2012
Xiao Q, Hu B, Yu CH, Xia LB, Jiang ZC (2006) Talanta 69:848–855
Ahmadi F, Assadi Y, Milani Hosseini SMR, Rezaee M (2006) J Chromatogr A 1101:307–312
Zhao EC, Han LJ, Jiang SR, Wang QX, Zhou ZQ (2006) J Chromatogr A 1114:269–273
Amvrazi EG, Tsiropoulos NG (2009) J Chromatogr A 1216:2789–2797
Khalili-Zanjani MR, Yamini Y, Yazdanfar N, Shariati S (2008) Anal Chim Acta 606:202–208
Wang XW, Luo LJ, Ouyang GF, Li L, Tam NFY, Lan CY, Luan TG (2009) J Chromatogr A 1216:6267–6273
López-Jiménez FJ, Rubio S, Pérez-Bendito D (2008) J Chromatogr A 1195:25–33
Chen H, Chen RW, Feng R, Li SQ (2009) Chromatographia 70:165–172
López-Blanco C, Gómez-Álvarez S, Rey-Garrote M, Cancho-Grande B, Simal-Gándara J (2005) Anal Bioanal Chem 383:557–561
Pinheiro AS, Andrade JB (2009) Talanta 79:1354–1359
Acknowledgments
This work was supported by the National Natural Science Foundation of China (Nos. 41176104, U1133003). We thank other laboratory colleagues for help during the work.
Author information
Authors and Affiliations
Corresponding authors
Rights and permissions
About this article
Cite this article
Tian, F., Liu, W., Fang, H. et al. Determination of Six Organophosphorus Pesticides in Water by Single-Drop Microextraction Coupled with GC-NPD. Chromatographia 77, 487–492 (2014). https://doi.org/10.1007/s10337-013-2609-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10337-013-2609-1