Overcoming high-field RF problems with non-magnetic Cartesian feedback transceivers

  • Research Article
  • Published:
Magnetic Resonance Materials in Physics, Biology and Medicine Aims and scope Submit manuscript

Abstract

In extending human MR to field strengths approaching 10 T, the wavelength of electromagnetic radiation at the proton Larmor frequency becomes less than human body size and conventional radio-frequency coil circumference. Consequently, radio-frequency magnetic fields are better generated by an array of small coils than by one large coil. In this article, the primary problem of array coil interactions during transmission is examined, and a standard proposed whereby secondary induced currents should be less than 1% of the primary coil current. The use of cancellation methods and of power amplifiers with high output impedance to reduce interactions is examined in the light of this standard and found wanting. Non-magnetic Cartesian feedback transceivers functioning at the magnet entrance are then proposed as a solution that both reduces instrumentation cost and increases the bandwidth over which the standard may be met. The compromises inherent in instrument design are detailed and examples given of the innovative circuitry used. It is shown experimentally that when connected to interacting coils, two Cartesian feedback instruments function stably in accord with theory and such that the proposed standard is typically attained over a bandwidth of 22 kHz during transmission (much greater during signal reception)—enough for all current MR protocols.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hoult DI, Chen C-N and Sank VJ (1986). The field dependence of NMR imaging. Magn Reson Med 3: 730–746

    Article  CAS  PubMed  Google Scholar 

  2. Hoult DI (2000). Sensitivity and power deposition in a high-field imaging experiment. J Magn Reson Imaging 12: 46–67

    Article  CAS  PubMed  Google Scholar 

  3. Sacolick LI, Rothman DL, de Graaf RA (2007) Adiabatic refocusing pulses for volume selection in magnetic resonance spectroscopic imaging. Magn Reson Med 57:548–553 and references therein

    Google Scholar 

  4. Roemer PB, Edelstein WA, Hayes CE, Sousa SP and Mueller OM (1990). The NMR phased array. Magn Reson Med 16: 192–225

    Article  CAS  PubMed  Google Scholar 

  5. Pruessman KP, Weiger M, Wiesinger F and Boesiger P (2002). An investigation into the role of coil coupling in parallel imaging. Proc Int Soc Magn Reson Med 10: 186

    Google Scholar 

  6. Ohliger MA, Ledden P, McKenzie CA and Sodickson DK (2004). Effects of inductive coupling on parallel MR image reconstructions. Magn Reson Med 52: 628

    Article  PubMed  Google Scholar 

  7. Andrew ER (1955) Nuclear magnetic resonance. Cambridge University Press, London, pp 56–63 and references therein

  8. Duensing GR, Brooker HR and Fitzsimmons JR (1996). Maximizing signal-to-noise ratio in the presence of coil coupling. J Magn Reson Ser B 11: 230–235

    Article  Google Scholar 

  9. Duensing GR, Peterson DM, Wolverton BL and Fitzsimmons JR (1998). Transceive phased array designed for imaging at 3.0 T. Proc Int Soc Magn Reson Med 6: 441

    Google Scholar 

  10. King SB, Duensing GR, Varosi S, Peterson DM and Molyneaux DA (2001). A four channel tranceive phased array head coil for 3 T. Proc Int Soc Magn Reson Med 9: 12

    Google Scholar 

  11. Wang J (1996). A novel method to reduce the signal coupling of surface coils for MRI. Proc Int Soc Magn Reson Med 4: 1434

    Google Scholar 

  12. Takahashi T, Matsunaga Y, Takeuchi H and Nishimura H (1996). Four-channel wrap-around coil with inductive decoupler for 1.5 T body imaging. Proc Int Soc Magn Reson Med 4: 1418

    Google Scholar 

  13. Schetgen R (ed) (1996). The ARRL handbook for radio amateurs. The American Radio Relay League, Newington

    Google Scholar 

  14. Straw RD (ed) (2000). The ARRL antenna book. The American Radio Relay League, Newington

    Google Scholar 

  15. Lange S and Nguyen QN (2006). Cables and electrodes can burn patients during MRI. Nursing 36: 18

    PubMed  Google Scholar 

  16. Lee RF, Giaquinto RO and Hardy CJ (2002). Coupling and decoupling theory and its application to the MRI phased array. Magn Reson Med 48: 203–213

    Article  PubMed  Google Scholar 

  17. Jevtic J (2001). Ladder networks for capacitive decoupling in phased-array coils. Proc Int Soc Magn Reson Med 9: 17

    Google Scholar 

  18. Dorf RC (ed) (1993). The electrical engineering handbook. CRC, Boca Raton

    Google Scholar 

  19. Hutchison JMS, Edelstein WA and Johnson G (1980). A whole-body NMR imaging machine. J Phys E: Sci Instrum 13: 947–955

    Article  Google Scholar 

  20. Hoult DI (1979). Fast recovery, high sensitivity probe and preamplifier for low frequencies. Rev Sci Instrum 50: 193–200

    Article  CAS  PubMed  Google Scholar 

  21. Hoult DI (1984). Fast recovery with a conventional probe. J Magn Reson 57: 394–403

    CAS  Google Scholar 

  22. Hoult DI and Ginsberg NS (2001). The quantum origins of the free induction decay signal and spin noise. J Magn Reson 148: 182–199

    Article  CAS  PubMed  Google Scholar 

  23. Kurpad KN, Boskamp EB and Wright SM (2004). Implementation of coil integrated RF power MOSFET as voltage controlled current source in a transmit phased array coil. Proc Int Soc Magn Reson Med 12: 1585

    Google Scholar 

  24. Chen C-N and Hoult DI (1989). Biomedical magnetic resonance technology. Adam Hilger, Bristol

    Google Scholar 

  25. Hoult DI (1991). Instrumentation and pulse sequences. Proc Eur Soc Magn Reson Med Biol, Zürich

    Google Scholar 

  26. Hoult DI, Kolansky G and Kripiakevich D (2004). A ‘Hi-Fi-Cartesian feedback spectrometer for precise quantitation and superior performance. J Magn Reson 171: 57–63

    Article  CAS  PubMed  Google Scholar 

  27. Hoult DI, Kolansky G, Kripiakevich D and King SB (2004). The NMR multi-transmit phased array: a Cartesian feedback approach. J Magn Reson 171: 64–70

    Article  CAS  PubMed  Google Scholar 

  28. Graeme JG, Tobey GE, Huelsman LP (eds) (1971). Operational amplifiers: design and applications. McGraw-Hill, New York

    Google Scholar 

  29. Hoult DI and Richards RE (1975). Critical factors in the design of sensitive high resolution nuclear magnetic resonance spectrometers. Proc R Soc Lond A 344: 311–340

    Article  CAS  Google Scholar 

  30. Morris RL, Miller JR (eds) (1971). Designing with TTL integrated circuits. Mc-Graw Hill, New York

    Google Scholar 

  31. Mitchell MW and Chiao RY (1998). Causality and negative group delays in a simple band-pass filter. Am J Phys 66: 14–19

    Article  Google Scholar 

  32. Hickman I (1993). Newnes practical RF handbook. Butterworth-Heinemann, Oxford

    Google Scholar 

  33. Koste G, Frey R, Nielsen M, Tolliver T, Watkins R (2005) Magnetic resonance imaging, a commercial application for analog photonics. In: Proceedings of the IEEE conference on avionics fiber-optics and photonics

  34. International Electrotechnical Commission, Geneva, Switzerland. Standard IEC 60601-2-33

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. I. Hoult.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hoult, D.I., Foreman, D., Kolansky, G. et al. Overcoming high-field RF problems with non-magnetic Cartesian feedback transceivers. Magn Reson Mater Phy 21, 15 (2008). https://doi.org/10.1007/s10334-007-0089-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10334-007-0089-8

Keywords

Navigation