Skip to main content

Advertisement

Log in

Surface Point Cloud Ultrasound with Transcranial Doppler: Coregistration of Surface Point Cloud Ultrasound with Magnetic Resonance Angiography for Improved Reproducibility, Visualization, and Navigation in Transcranial Doppler Ultrasound

  • Original Paper
  • Published:
Journal of Digital Imaging Aims and scope Submit manuscript

Abstract

Transcranial Doppler (TCD) ultrasound is a standard tool used in the setting of recent sub-arachnoid hemorrhage (SAH). By tracking velocity in the circle-of-Willis vessels, vasospasm can be detected as interval velocity increase. For this disease process, repeated TCD velocity measurements over many days is the basis for its usefulness. However, a key limitation to TCD is its user dependence, which is itself largely due to the fact that exact information about probe positioning is lost between subsequent scans. Surface point cloud ultrasound (SPC-US) was recently introduced as a general approach combining ultrasound and three-dimensional surface imaging of patient + probe. In the present proof-of-principle demonstration, we have applied SPC-US to TCD and co-registered the skin surface with that from MRA images to provide a roadmap of the vasculature in 3D space for better speed, accuracy, reproducibility, and potential semi-automation of TCD. Collating the acronyms, we call the combined approach SPC-US-TCD. TCD of the M1 was obtained while three-dimensional photographic images were obtained with the Structure Sensor camera. MRA imaging was also obtained. SPC-US-TCD and corresponding MRA 3D reconstruction images were co-registered in MeshMixer using the skin surfaces for alignment. A cylinder the width of the TCD probe was placed over the fused images and aligned with the direction and orientation of the TCD probe to demonstrate the acoustic beam. In the fused images, the acoustic beam intersects the right M1 segment of the middle cerebral artery (MCA). The angle of insonation is well demonstrated and measurable in various planes. Distance measurements made in Blender localized the TCD probe position based on three skin surface landmarks, and tabulated orientation based on three angles along the corresponding directions. SPC-US-TCD provides valuable information that is otherwise not present in TCD studies. By co-registering SPC-US-TCD data with that from cross sectional vessel imaging, precise probe location relative to external skin surface landmarks as well as 3D vessel location relative to TCD probe placement offers the potential to provide a roadmap that improves exam reproducibility, speed of acquisition, and accuracy. The goal of future work is to demonstrate this improvement statistically by application to multiple patients and scans.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Aaslid R, Markwalder T-M, Nornes H: Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg. 57(6):769–774, 1982

    Article  CAS  PubMed  Google Scholar 

  2. Morris NA, Manning N, Marshall RS, Connolly ES, Claassen J, Agarwal S, Roh DJ, Schmidt JM, Park S: Transcranial Doppler waveforms during intra-aortic balloon pump Counterpulsation for vasospasm detection after subarachnoid hemorrhage. Neurosurgery. 83(3):416–421, 2018

    Article  PubMed  Google Scholar 

  3. Robba C, Goffi A, Geeraerts T, Cardim D, Via G, Czosnyka M, Park S, Sarwal A, Padayachy L, Rasulo F, Citerio G: Brain ultrasonography: Methodology, basic and advanced principles and clinical applications. A narrative review. Intensive Care Med. 45(7):913–927, 2019

    Article  PubMed  Google Scholar 

  4. Kirsch JD, Mathur M, Johnson MH, Gowthaman G, Scoutt LM: Advances in Transcranial Doppler US: Imaging ahead. RadioGraphics. 33(1):E1–E14, 2013

    Article  PubMed  Google Scholar 

  5. Kramer DR, Winer JL, Pease BAM, Amar AP, Mack WJ: Cerebral vasospasm in traumatic brain injury. Neurol Res Int. 2013:1–7, 2013

    Article  Google Scholar 

  6. Kassell NF, Sasaki T, Colohan AR, Nazar G: Cerebral vasospasm following aneurysmal subarachnoid hemorrhage. Stroke. 16(4):562–572, 1985

    Article  CAS  PubMed  Google Scholar 

  7. Kreiter KT, Mayer SA, Howard G, Knappertz V, Ilodigwe D, Sloan MA, Macdonald RL: Sample size estimates for clinical trials of vasospasm in subarachnoid hemorrhage. Stroke. 40(7):2362–2367, 2009

    Article  PubMed  Google Scholar 

  8. Kassell NF, Torner JC, Haley EC et al.: The international cooperative Studyon the timing of aneurysm surgery. J Neurosurg. 73(1):18–36, 1990

    Article  CAS  PubMed  Google Scholar 

  9. Chadduck WM, Crabtree HM, Blankenship JB, Adametz J: Transcranial Doppler ultrasonography for the evaluation of shunt malfunction in pediatric patients. Childs Nerv Syst. 7(1):27–30, 1991

    Article  CAS  PubMed  Google Scholar 

  10. Kral MC, Brown RT, Curé JK, Besenski N, Jackson SM, Abboud MR: Radiographic predictors of neurocognitive functioning in pediatric sickle cell disease. J Child Neurol. 21(1):37–44, 2006

    Article  PubMed  Google Scholar 

  11. Rasulo FA, De Peri E, Lavinio A: Transcranial Doppler ultrasonography in intensive care. Eur J Anaesthesiol. 25:167–173, 2008

    Article  Google Scholar 

  12. Rubin JM: Spectral Doppler US. RadioGraphics. 14(1):139–150, 1994

    Article  CAS  PubMed  Google Scholar 

  13. Taylor KJ, Holland S: Doppler US. Part I. Basic principles, instrumentation, and pitfalls. Radiology. 174(2):297–307, 1990

    Article  CAS  PubMed  Google Scholar 

  14. Nelson T, Pretorius D: The Doppler signal: Where does it come from and what does it mean? Am J Roentgenol. 151(3):439–447, 1988

    Article  CAS  Google Scholar 

  15. Illig KA, Ouriel K, DeWeese JA, Holen J, Green RM: Measurement of carotid bifurcation pressure gradients using the Bernoulli principle. Cardiovasc Surg. 4(2):130–134, 1996

    Article  CAS  PubMed  Google Scholar 

  16. Lupetin AR, Davis DA, Beckman I, Dash N: Transcranial Doppler sonography. Part 1. Principles, technique, and normal appearances. RadioGraphics. 15(1):179–191, 1995

    Article  CAS  PubMed  Google Scholar 

  17. Thomsen LL, Iversen HK: Experimental and biological variation of three-dimensional transcranial Doppler measurements. J Appl Physiol. 75(6):2805–2810, 1993

    Article  CAS  PubMed  Google Scholar 

  18. Kaczynski J, Home R, Shields K, Walters M, Whiteley W, Wardlaw J, Newby DE: Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery. Cardiovasc Ultrasound. 16(1):15, 2018

    Article  PubMed  PubMed Central  Google Scholar 

  19. Maeda H, Etani H, Handa N, Tagaya M, Oku N, Kim BH, Naka M, Kinoshita N, Nukada T, Fukunaga R: A validation study on the reproducibility of transcranial doppler velocimetry. Ultrasound Med Biol. 16(1):9–14, 1990

    Article  CAS  PubMed  Google Scholar 

  20. Shen Q, Stuart J, Venkatesh B, Wallace J, Lipman J: Inter observer variability of the transcranial doppler ultrasound technique: Impact of lack of practice on the accuracy of measurement. J Clin Monit Comput. Kluwer Academic Publishers 15(3–4):179–184, 1999

    Article  CAS  PubMed  Google Scholar 

  21. Ceravolo MG, Minciotti P, Orlandini M, Provinciali L: Intra- and inter-observer variability of basal flow velocity and vascular reactivity measurements using transcranial Doppler sonography. Neurol Res. 14(2 Suppl):122–124, 1992

    Article  CAS  PubMed  Google Scholar 

  22. Demolis P, Chalon S, Giudicelli JF: Repeatability of transcranial Doppler measurements of arterial blood flow velocities in healthy subjects. Clin Sci. 84(6):599–604, 1993

    Article  CAS  PubMed  Google Scholar 

  23. Blanco P, Blaivas M: Applications of Transcranial color-coded Sonography in the emergency department. J Ultrasound Med. 36(6):1251–1266, 2017

    Article  PubMed  Google Scholar 

  24. Rigamonti A, Ackery A, Baker AJ: Transcranial Doppler monitoring in subarachnoid hemorrhage: A critical tool in critical care. Can J Anaesth. 55(2):112–123, 2008

    Article  PubMed  Google Scholar 

  25. Arkuszewski M, Swiat M, Hurst RW et al.: Vertebral and basilar arteries: Transcranial color-coded duplex ultrasonography versus conventional TCD in detection of narrowings. Neuroradiol J. Edizioni del Centauro 25(5):509–514, 2012

    Article  CAS  Google Scholar 

  26. Swiercz M, Swiat M, Pawlak M et al.: Narrowing of the middle cerebral artery: Artificial intelligence methods and comparison of transcranial color coded duplex sonography with conventional TCD. Ultrasound Med Biol. 36(1):17–28, 2010

    Article  PubMed  Google Scholar 

  27. Auer A, Felber S, Lutz W et al.: Transcranial Doppler sonography guided by magnetic resonance angiography for improved monitoring of intracranial arteries. J. Neuroimaging. Lippincott Williams and Wilkins:34–38, 1999

  28. Kantelhardt SR, Greke C, Keric N, Vollmer F, Thiemann I, Giese A: Image Guidance for Transcranial Doppler Ultrasonography. Oper Neurosurg 68(suppl_2):ons257–ons266, 2011

    Article  Google Scholar 

  29. Greke C, Neulen A, Kantelhardt SR, Birkenmayer A, Vollmer FC, Thiemann I, Giese A: Image-guided Transcranial Doppler Sonography for monitoring of defined segments of intracranial arteries. J Neurosurg Anesthesiol. 25(1):55–61, 2013

    Article  PubMed  Google Scholar 

  30. Stember JN: Three-dimensional surface point cloud ultrasound for better understanding and transmission of ultrasound scan information. J Digit Imaging. 31(6):904–911, 2018

    Article  PubMed  PubMed Central  Google Scholar 

  31. Pozniak MA, Zagzebski JA, Scanlan KA: Spectral and color Doppler artifacts. Radiographics. 12(1):35–44, 1992

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. N. Stember.

Ethics declarations

Conflict of Interest

On behalf of all authors, the corresponding author states that there is no conflict of interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Stember, J.N., Terilli, K.L., Perez, E. et al. Surface Point Cloud Ultrasound with Transcranial Doppler: Coregistration of Surface Point Cloud Ultrasound with Magnetic Resonance Angiography for Improved Reproducibility, Visualization, and Navigation in Transcranial Doppler Ultrasound. J Digit Imaging 33, 930–936 (2020). https://doi.org/10.1007/s10278-020-00328-y

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-020-00328-y

Keywords

Navigation