Skip to main content
Log in

Development and Evaluation of a Low-Cost and High-Capacity DICOM Image Data Storage System for Research

  • Published:
Journal of Digital Imaging Aims and scope Submit manuscript

Abstract

Thin-slice CT data, useful for clinical diagnosis and research, is now widely available but is typically discarded in many institutions, after a short period of time due to data storage capacity limitations. We designed and built a low-cost high-capacity Digital Imaging and COmmunication in Medicine (DICOM) storage system able to store thin-slice image data for years, using off-the-shelf consumer hardware components, such as a Macintosh computer, a Windows PC, and network-attached storage units. “Ordinary” hierarchical file systems, instead of a centralized data management system such as relational database, were adopted to manage patient DICOM files by arranging them in directories enabling quick and easy access to the DICOM files of each study by following the directory trees with Windows Explorer via study date and patient ID. Software used for this system was open-source OsiriX and additional programs we developed ourselves, both of which were freely available via the Internet. The initial cost of this system was about $3,600 with an incremental storage cost of about $900 per 1 terabyte (TB). This system has been running since 7th Feb 2008 with the data stored increasing at the rate of about 1.3 TB per month. Total data stored was 21.3 TB on 23rd June 2009. The maintenance workload was found to be about 30 to 60 min once every 2 weeks. In conclusion, this newly developed DICOM storage system is useful for research due to its cost-effectiveness, enormous capacity, high scalability, sufficient reliability, and easy data access.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Meenman C, Daly B, Toland C, Nagy P: Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets. J Digit Imaging 19(suppl 1):84–88, 2006

    Article  Google Scholar 

  2. Ooijen P, Broekema A, Oudkerk M: Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets — A Reviewers’ Response. J Digit Imaging 21(2):188–192, 2008

    Article  PubMed  Google Scholar 

  3. Voellmy DR, Handgratinger O, Wildermuth S, Frohlich B,Marincek B: Total cost of high volume multi-detector CT data management. Computer Assisted Radiology and Surgery (CARS) 2004. Int Congr Ser 1268:249Y253, 2004

    Article  Google Scholar 

  4. Moore’s Law. Available at http://en.wikipedia.org/wiki/Moores_law. Accessed on July 13, 2009

  5. Rosset A, Spadola L, Ratib O: OsiriX: An open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17(3):205–216, 2004

    Article  PubMed  Google Scholar 

  6. YAKAMI DICOM Tools. Available at http://www.kuhp.kyoto-u.ac.jp/∼diag_rad/intro/tech/dicom_tools.html. Accessed on July 13, 2009

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Koichi Ishizu.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yakami, M., Ishizu, K., Kubo, T. et al. Development and Evaluation of a Low-Cost and High-Capacity DICOM Image Data Storage System for Research. J Digit Imaging 24, 190–195 (2011). https://doi.org/10.1007/s10278-009-9267-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-009-9267-8

Key words

Navigation