Objective

This paper describes a high-quality, multisite telemammography system to enable “almost real-time” remote patient management while the patient remains in the clinic. One goal is to reduce the number of women who would physically need to return to the clinic for additional imaging procedures (termed “recall”) to supplement “routine” imaging of screening mammography.

Materials and Methods

Mammography films from current and prior (when available) examinations are digitized at three remote sites and transmitted along with other pertinent information across low-level communication systems to the central site. Images are automatically cropped, wavelet compressed, and encrypted prior to transmission to the central site. At the central site, radiologists review and rate examinations on a high-resolution workstation that displays the images, computer-assisted detection results, and the technologist's communication. Intersite communication is provided instantly via a messaging “chat” window.

Results

The technologists recommended additional procedures at 2.7 times the actual clinical recall rate for the same cases. Using the telemammography system during a series of “off-line” clinically simulated studies, radiologists recommended additional procedures at 1.3 times the actual clinical recall rate. Percent agreement and kappa between the study and actual clinical interpretations were 66.1% and 0.315, respectively. For every physical recall potentially avoided using the telemammography system, approximately one presumed “unnecessary” imaging procedure was recommended.

Conclusion

Remote patient management can reduce the number of women recalled by as much as 50% without performing an unreasonable number of presumed “unnecessary” procedures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. SH Taplin L Ichikawa DS Buist D Seger E White (2004) ArticleTitleEvaluating organized breast cancer screening implementation: the prevention of late-stage disease? Cancer Epidemiol Biomark Prev 13 IssueID2 225–234 Occurrence Handle10.1158/1055-9965.EPI-03-0206

    Article  Google Scholar 

  2. LL Humphrey M Helfand BKS Chan SH Woolf (2002) ArticleTitleBreast cancer screening: a summary of the evidence for the U.S. preventive services task force Ann Intern Med 137 IssueID5, Part 1 E347–E367

    Google Scholar 

  3. JG Elmore LM Reisch MB Barton WE Barlow S Rolnick EL Harris LJ Herrinton AM Geiger RK Beverly G Hart O Yu SM Greene NS Weiss SW Fletcher (2005) ArticleTitleEfficacy of breast cancer screening in the community according to risk level J Natl Cancer Inst 97 IssueID14 1035–1043 Occurrence Handle16030301 Occurrence Handle10.1093/jnci/dji183

    Article  PubMed  Google Scholar 

  4. AB Miller T To CJ Baines C Wall (2002) ArticleTitleThe Canadian Nation Breast Screening Study-1: breast cancer mortality after 11 to 16 years of follow-up: a randomized screening trial of mammography in women age 40 to 49 years Ann Intern Med 137 IssueID5, Part 1 E305–E315

    Google Scholar 

  5. JG Elmore CK Wells CH Lee DH Howard AR Feinstein (1994) ArticleTitleVariability in radiologists' interpretations of mammograms N Engl J Med 331 IssueID22 1493–1499 Occurrence Handle7969300 Occurrence Handle1:STN:280:DyaK2M%2FlvFamtw%3D%3D Occurrence Handle10.1056/NEJM199412013312206

    Article  PubMed  CAS  Google Scholar 

  6. RML Warren SW Duffy (1995) ArticleTitleComparison of single reading with double reading of mammograms and change in effectiveness with experience Br J Radiol 68 IssueID813 958–962 Occurrence Handle7496693 Occurrence Handle1:STN:280:DyaK28%2FpslOlsQ%3D%3D Occurrence Handle10.1259/0007-1285-68-813-958

    Article  PubMed  CAS  Google Scholar 

  7. B Sandin P Chorot RM Valiente L Lostao MA Santed (2002) ArticleTitleAdverse psychological effects in women attending a second-stage breast cancer screening J Psychosom Res 52 IssueID5 303–309 Occurrence Handle12023127 Occurrence Handle10.1016/S0022-3999(01)00227-6

    Article  PubMed  Google Scholar 

  8. KK Lindfors J O'Connor RA Parker (2001) ArticleTitleFalse-positive screening mammograms: effect of immediate versus later work-up on patient stress Radiology 218 IssueID1 247–253 Occurrence Handle11152810 Occurrence Handle1:STN:280:DC%2BD3MzitFCnuw%3D%3D

    PubMed  CAS  Google Scholar 

  9. NC Dolan MM McDermott M Morrow L Venta GJ Martin (1999) ArticleTitleImpact of same-day screening mammography availability: results of a controlled clinical trial Arch Intern Med 159 IssueID4 393–398 Occurrence Handle10030314 Occurrence Handle1:STN:280:DyaK1M7ltlertw%3D%3D Occurrence Handle10.1001/archinte.159.4.393

    Article  PubMed  CAS  Google Scholar 

  10. JG Elmore MB Barton VM Moceri S Polk PJ Arena SW Fletcher (1998) ArticleTitleTen-year risk of false-positive screening mammograms and clinical breast examinations N Engl J Med 338 IssueID16 1089–1096 Occurrence Handle9545356 Occurrence Handle1:STN:280:DyaK1c7ps1Kitw%3D%3D Occurrence Handle10.1056/NEJM199804163381601

    Article  PubMed  CAS  Google Scholar 

  11. BC Yankaskas RJ Cleveland MJ Schell R Kozar (2001) ArticleTitleAssociation of recall rates with sensitivity and positive predictive values of screening mammography AJR Am J Roentgenol 177 IssueID3 543–549 Occurrence Handle11517044 Occurrence Handle1:STN:280:DC%2BD3MvotF2hsA%3D%3D

    PubMed  CAS  Google Scholar 

  12. DS May NC Lee MR Nadel RM Henson DS Miller (1998) ArticleTitleThe national breast and cervical cancer early detection program: report of the first 4 years of mammography provided to medically underserved women AJR Am J Roentgenol 170 IssueID1 97–104 Occurrence Handle9423608 Occurrence Handle1:STN:280:DyaK1c%2FosFKltA%3D%3D

    PubMed  CAS  Google Scholar 

  13. JH Sumkin HM Klaman M Graham T Ruskauff RC Gennari JL King AH Klym MA Ganott D Gur (2003) ArticleTitlePrescreening mammography by technologists: a preliminary assessment AJR Am J Roentgenol 180 IssueID1 253–256 Occurrence Handle12490515

    PubMed  Google Scholar 

  14. JM Tonita JP Hillis CH Lim (1999) ArticleTitleMedical radiologic technologist review: effects on a population-based breast cancer screening program Radiology 211 IssueID2 529–533 Occurrence Handle10228538 Occurrence Handle1:STN:280:DyaK1M3ksFahsA%3D%3D

    PubMed  CAS  Google Scholar 

  15. SA Feig MJ Yaffe (1995) ArticleTitleDigital mammography, computer-aided diagnosis, and telemammography Radiol Clin North Am 33 IssueID6 1205–1228 Occurrence Handle7480666 Occurrence Handle1:STN:280:DyaK28%2Fos12ksg%3D%3D

    PubMed  CAS  Google Scholar 

  16. MA Goldberg SJ Dwyer Suffix3rd (1995) ArticleTitleTelemammography: implementation issues Telemed J 1 IssueID3 215–226 Occurrence Handle10165158 Occurrence Handle1:STN:280:DyaK2s3gvVKhtw%3D%3D

    PubMed  CAS  Google Scholar 

  17. SL Lou HD Lin KP Lin D Hoogstrate (2000) ArticleTitleAutomatic breast region extraction from digital mammograms for PACS and telemammography applications Comput Med Imaging Graph 24 IssueID4 205–220 Occurrence Handle10842045 Occurrence Handle1:STN:280:DC%2BD3czosFejtQ%3D%3D Occurrence Handle10.1016/S0895-6111(00)00009-4

    Article  PubMed  CAS  Google Scholar 

  18. JM Murphy NJ O'Hare D Wheat PA McCarthy A Dowling R Hayes H Bowmer GF Wilson MP Molloy (1999) ArticleTitleDigitized mammograms: a preliminary clinical evaluation and the potential for telemammography J Telemed Telecare 5 IssueID3 193–197 Occurrence Handle10628036 Occurrence Handle1:STN:280:DC%2BD3c%2FptlGhsQ%3D%3D Occurrence Handle10.1258/1357633991933620

    Article  PubMed  CAS  Google Scholar 

  19. SL Lou EA Sickles HK Huang D Hoogstrate F Cao J Wang M Jahangiri (1997) ArticleTitleFull-field direct digital telemammography: technical components, study protocols, and preliminary results IEEE Trans Inf Technol Biomed 1 IssueID4 270–278 Occurrence Handle11020830 Occurrence Handle1:STN:280:DC%2BD3cvmslCntA%3D%3D Occurrence Handle10.1109/4233.681171

    Article  PubMed  CAS  Google Scholar 

  20. GS Maitz TS Chang JH Sumkin PW Wintz CM Johns M Ganott BL Holbert CM Hakim KM Harris D Gur JM Herron (1997) ArticleTitlePreliminary clinical evaluation of a high-resolution telemammography system Invest Radiol 32 IssueID4 236–240 Occurrence Handle9101359 Occurrence Handle1:STN:280:DyaK2s3ls1Shug%3D%3D Occurrence Handle10.1097/00004424-199704000-00007

    Article  PubMed  CAS  Google Scholar 

  21. JM Drescher GS Maitz C Traylor JK Leader RJ Clearfield R Shah MA Ganott F Pugliese D Duffner J Lockhart D Gur (2003) ArticleTitleA multi-site telemammography system: preliminary assessment of technical and operational issues Proc SPIE 5033 360–369

    Google Scholar 

  22. JK Leader JH Sumkin MA Ganott C Hakim L Hardesty R Shah L Wallace A Klym JM Drescher GS Maitz D Gur (2004) ArticleTitleSubjective assessment of high-level image compression of digitized mammograms Proc SPIE 5372 415–422

    Google Scholar 

  23. BJ Lucier M Kallergi W Qian RA DeVore RA Clark EB Saff LP Clarke (1994) ArticleTitleWavelet compression and segmentation of digital mammograms J Digit Imaging 7 IssueID1 27–38 Occurrence Handle8172976 Occurrence Handle1:STN:280:DyaK2c3islWguw%3D%3D Occurrence Handle10.1007/BF03168476

    Article  PubMed  CAS  Google Scholar 

  24. SM Perlmutter PC Cosman RM Gray RA Olshen D Ikeda CN Adams BJ Betts MB Williams KO Perlmutter J Li A Aiyer L Fajardo R Birdwell BL Daniel (1997) ArticleTitleImage quality in lossy compressed digital mammograms Signal Process 59 IssueID2 189–210 Occurrence Handle10.1016/S0165-1684(97)00046-7

    Article  Google Scholar 

Download references

Acknowledgments

This work is supported in part by the US Army Medical Research Acquisition Center, 820 Chandler Street, Fort Detrick, MD 21702-5014, under contract DAMD17-00-1-0410. The content of the information contained herein does not necessarily reflect the position or the policy of the government, and no official endorsement should be inferred.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Joseph K. Leader Ph.D..

Rights and permissions

Reprints and permissions

About this article

Cite this article

Leader, J.K., Hakim, C.M., Ganott, M.A. et al. A Multisite Telemammography System for Remote Management of Screening Mammography: An Assessment of Technical, Operational, and Clinical Issues. J Digit Imaging 19, 216–225 (2006). https://doi.org/10.1007/s10278-006-0585-9

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-006-0585-9

Key Words

Navigation