Abstract

In orthopaedics, conventional implant plates such as locking compression plate (LCP) made from non-biodegradable materials play a vital role in the fixation to support bone fractures, but also create a complication such as stress shielding. These again require a painful surgery to remove/replace after they have healed as it does not degrade into the physiological environment (PE). Currently, there has already been enough discovery of biodegradable materials that, despite being mechanically inefficient compared to non-biodegradable materials, can completely be biodegraded in PE during and after healing to avoid such problems. While there has been insufficient research on the design of biodegradable implant plates, the implementation of which may help achieve the goal with an effort of high mechanical strength. A novel design of biodegradable embossed locking compression plate (BELCP) is designed for biodegradable materials to approach superior mechanical performance and complete degradation over time, considering all such parameters and factors. For biomechanical evaluation, four-point bending test (4PBT), axial compressive and tensile test (ACTT) and torsion test (TT) have been performed on LCP, BELCP and its continuously degraded forms made of biodegradable material (Mg-alloy) using finite element method. BELCP has found 50%, 100% and 100% higher mechanical performance and safer in 4PBT, ACTT and TT, respectively, than LCP. Moreover, BELCP has also observed safe during continuous degradation up to 6 months after implantation under these three tests, considering an approximate sustained degradation rate of about 4 mm/year. Even Mg-alloy made BELCP can be sufficient and safer to support fractured bone than SS-alloy made LCP, but not Ti-alloy made LCP. BELCP can be a successful biodegradable bone implant plate after human/animal trials in the future.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3.
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

References

Download references

Funding

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Girish Chandra.

Ethics declarations

Conflict of interest

No conflicts to declare in any way.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chandra, G., Pandey, A. Biomechanical evaluation on a novel design of biodegradable embossed locking compression plate for orthopaedic applications using finite element analysis. Biomech Model Mechanobiol 21, 1371–1392 (2022). https://doi.org/10.1007/s10237-022-01596-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10237-022-01596-z

Keywords

Navigation