Abstract
An inverse finite element method was developed to determine the anisotropic properties of bovine cornea from an in vitro inflation experiment. The experiment used digital image correlation (DIC) to measure the three-dimensional surface geometry and displacement field of the cornea at multiple pressures. A finite element model of a bovine cornea was developed using the DIC measured surface geometry of the undeformed specimen. The model was applied to determine five parameters of an anisotropic hyperelastic model that minimized the error between the measured and computed surface displacement field and to investigate the sensitivity of the measured bovine inflation response to variations in the anisotropic properties of the cornea. The results of the parameter optimization revealed that the collagen structure of bovine cornea exhibited a high degree of anisotropy in the limbus region, which agreed with recent histological findings, and a transversely isotropic central region. The parameter study showed that the bovine corneal response to the inflation experiment was sensitive to the shear modulus of the matrix at pressures below the intraocular pressure, the properties of the collagen lamella at higher pressures, and the degree of anisotropy in the limbus region. It was not sensitive to a weak collagen anisotropy in the central region.
This is a preview of subscription content, access via your institution.
References
Aghamohammadzadeh H, Newton RH, Meek KM (2005) X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus. Structure 12: 249–256
Alastrué V, Calvo B, Pena E, Doblaré M (2006) Biomechanical modeling of refractive corneal surgery. J Biomech Eng 128: 150–160
Bischoff JE (2006) Reduced parameter formulation for incorporating viscoelasticity into tissue level biomechanics. Ann Biomed Eng 34: 1164–1172
Boote C, Dennis S, Huang Y, Quantock AJ, Meek KM (2005) Lamellar orientation in human cornea in relation to mechanical properties. J Struct Biol 149: 1–6
Boote C, Dennis S, Meek KM (2004) Spatial mapping of collagen fibril organisation in primate cornea—an X-ray diffraction investigation. J Struct Biol 146: 359–367
Boote C, Hayes S, Jones S, Qantock AJ, Hocking PM, Inglehearn CF, Ali M, Meek KM (2007) Collagen organization in the chicken cornea and structural alterations in the retinopathy, globe enlarged (rge) phenotype—an x-ray diffraction study. J Struct Biol 161: 1–8
Boyce BL, Grazier JM, Jones RE, Nguyen TD (2008) Full-field deformation of bovine cornea under constrained inflation conditions. Biomaterials 28: 3896–3904
Bryant MR, McDonnell PJ (1996) Constitutive laws for biomechanical modeling of refractive surgery. J Biomech Eng 118: 473–481
Bryant MR, Velinsky SA (1991) Design of keratorefractive surgical procedures: radial keratotomy. J Biomech Eng 113: 150–157
Bryant MR, Velinsky SA, Plesha ME, Clarke GP (1987) Computer-aided surgical design in refractive keratotomy. The CLO J 13: 238–242
Cogan DG (1951) Applied anatomy and physiology of the cornea. Trans Am Ophthalmol Soc 55: 329
Daxer A, Fratzl P (1997) Collagen fibril orientation in the corneal stroma and its implications in keratoconous. Invest Ophthalmol Vis Sci 38: 121–129
Freund DE, McCally RL, Farrell RA, Cristol SM, Lhernault NL, Edelhauser HF (1995) Ultrastructure in anterior and posterior stroma of perfused human and rabbit corneas-relation to transparency. Invest Ophthalmol Vis Sci 36: 1508–1523
Fung YC (1993) Biomechanics: mechanical properties of living tissues. Springer, New York, NY
Gasser TC, Ogden RW, Holzapfel GA (2006) Hyperelastic modelling of arterial layers with distributed collagen fibre orientations. J R Soc Interface 3: 15–35
Girard MJA, Downs JC (2009) Peripapillary and posterior scleral mechanics—part i: development of an anisotropic hyperelastic constitutive model. J Biomech Eng 131: 051011
Gokhale NH, Barbone PE, Oberai AA (2008) Solution of the nonlinear elasticity imaging inverse problem: the compressible case. Inverse Probl 24: 045010
Gum GG, Gelatt KN, Miller DN, Mackay EO (1998) Intraocular pressure in normal dairy cattle. Vet Opthalmol 1: 159–161
Hanna KD, Jouve FE, Waring GO (1989) Preliminary computer simulation of the effects of radial keratotomy. Arch Ophthalmol 107: 911–918
Hayes S, Boote C, Lewis J, Sheppard J, Abahussin M, Quantock AJ, Purslow C, Votruba M, Meek KM (2007) Comparative study of fibrillar collagen arrangement in the corneas of primates and other mammals. Anat Rec 290: 1542–1550
Holzapfel GA (2000) Nonlinear solid mechanics: a continuum approach for engineers. John Wiley and Sons, LTD, Chichester
Lanir Y (1983) Constitutive equations for fibrous connective tissues. J Biomech 16: 1–12
Maurice DM (1957) The structure and transparency of the cornea. J Physiol 136: 263–286
Maurice DM (1984) The cornea and sclera. In: Davson H (eds) The eye. Academic Press, New York, pp 1–158
Meek KM, Blamiers T, Elliott GF, Gyi TJ, Nave C (1987) The organization of collagen fibrils in the human corneal stroma: a synchrotron X-ray diffraction study. Curr Eye Res 6: 841–846
Meek KM, Tuft SJ, Huang Y, Gill PS, Hayes S, Newton RH, Bron AJ (2005) Changes in collagen orientation and distribution in keratoconus cornea. Invest Ophthalmol Vis Sci 46: 1948–1956
Nguyen TD, Jones RE, Boyce BL (2007) Modeling the anisotropic finite-deformation viscoelastic behavior of soft fiber-reinforced composites. Int J Solids Struct 44: 8366–8389
Nguyen TD, Jones RE, Boyce BL (2008) A nonlinear anisotropic viscoelastic model for the tensile behavior of the corneal stroma. J Biomech Eng 130: 041020
Oberai AA, Gokhale NH, Feijoo GR (2003) Solution of inverse problems in elasticity imaging using the adjoint method. Inverse Probl 19: 297–313
Pandolfi A, Fotia G, Manganiello F (2009) Finite element simulations of laser refractive corneal surgery. Eng Comput 25: 15–24
Pandolfi A, Holzapfel G (2008) Three-dimensional modeling and computational analysis of the human cornea considering distributed collagen fibril orientations. J Biomech Eng 130: 061006
Pandolfi A, Manganiello F (2006) A model for the human cornea: constitutive formulation and numerical analysis. Biomech Model Mechanobiol 5: 237–246
Pinsky PM, Datye DV (1991) A microstructurally-based finite element model of the incised human cornea. J Biomech 24: 907–922
Pinsky PM, van der Heide D, Chernyak D (2005) Computational modeling of mechanical anisotropy in the cornea and schlera. J Cataract Refract Surg 31: 136–145
Sacks MS (2003) Incorporation of experimentally-derived fiber orientation into a structural constitutive model for planar collagenous tissues. J Biomech Eng 125: 280–287
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nguyen, T.D., Boyce, B.L. An inverse finite element method for determining the anisotropic properties of the cornea. Biomech Model Mechanobiol 10, 323–337 (2011). https://doi.org/10.1007/s10237-010-0237-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10237-010-0237-3