Abstract
Hospital-acquired legionellosis is one of the serious problems in nosocomial infection. For risk assessment of nosocomial Legionella infection, we surveyed samples from bathrooms for public use in three hospitals and two nursing homes to determine whether Legionella pneumophila was present. A total of 70 hot bathwater samples and samples wiped from bathtubs were collected at 1-h intervals. Fifteen shower-water and 15 inner-head samples were obtained at the start of a bath. Water samples were cultured using the Legionella spp. selective medium, and discrimination between L. pneumophila and other Legionella spp. was performed by PCR analysis. L. pneumophila serogroup 7 was detected in 1 bathwater and 1 wiped sample, both of which were collected 1 h after daily use from the same bathtub in a hospital. However, L. pneumophila SG7 was not detected in any other samples. Furthermore, the concentrations of free residual chlorine in most bath- and shower-water samples were lower than 0.1 mg/l. These results suggest that L. pneumophila has become a potential pathogen for nosocomial infections in public-type hospital baths. From the point of view of an infection-control program, it might be advisable to hold the concentration of free residual chlorine at 0.2–0.4 mg/l, which is generally required for public baths in Japan.
Similar content being viewed by others
References
JE McDade CC Shepard DW Faser (1977) ArticleTitleLegionnaires' disease. Isolation of a bacterium and demonstration of its role in other respiratory disease N Engl J Med 297 1197–203 Occurrence Handle1:STN:280:DyaE1c%2FjtFWjtA%3D%3D Occurrence Handle335245 Occurrence Handle10.1056/NEJM197712012972202
P Visca P Goldoni PC Luck JH Helbig L Cattani G Giltri et al. (1999) ArticleTitleMultiple types of Legionella pneumophila serogroup 6 in a hospital heated-water system associated with sporadic infections J Clin Microbiol 37 2189–96 Occurrence Handle1:STN:280:DyaK1M3psVOmtw%3D%3D Occurrence Handle10364584
JL Kool D Bergmire-Sweat JC Butler EW Brown DJ Peabody DS Massi et al. (1999) ArticleTitleHospital characteristics associated with colonization of water systems by Legionella and risk of nosocomial Legionnaires' disease: a cohort study of 15 hospitals Infect Control Hosp 20 798–805 Occurrence Handle10.1086/501587 Occurrence Handle1:STN:280:DC%2BD3c%2FotVaguw%3D%3D
DB Jernigan J Hofman MS Cetron CA Genese JP Nuorti BS Fields et al. (1996) ArticleTitleOutbreak of Legionnaires disease among cruise ship passengers exposed to a contaminated whirlpool spa Lancet 347 494–9 Occurrence Handle10.1016/S0140-6736(96)91137-X Occurrence Handle1:STN:280:DyaK287nsVOjtA%3D%3D Occurrence Handle8596266
BN Doebbling RP Wenzel (1987) ArticleTitleThe epidemiology of Legionella pneumophila infections Semin Respir Infect 2 206–21
N Yamamoto T Kubota M Tateyama M Koide C Nakasone M Tohyama et al. (2003) ArticleTitleIsolation of Legionella anisa from multiple sites of a hospital water system: the eradication of Legionella contamination J Infect Chemother 9 122–5 Occurrence Handle12825109
The Minister of Health and Welfare, Japan. The manual for prevention of Legionnaires' disease in public whirlpool bath. 2001. http://www.mhlw.go.jp/topics/2001/0109/tp0911-1.html (in Japanese)
K Rantakokko-Jalava J Jalava (2001) ArticleTitleDevelopment of conventional and real-time PCR assays for detection of Legionella DNA in respiratory specimens J Clin Microbiol 39 2904–10 Occurrence Handle10.1128/JCM.39.8.2904-2910.2001 Occurrence Handle1:CAS:528:DC%2BD3MXmsVOmsrg%3D Occurrence Handle11474011
T Fujii M Ohta M Kono S Hoshiya K Fukuhara M Tsuruoka (1999) ArticleTitleRapid detection of the gene of Legionella pneumophila using the fluorescence polarization with the asymmetric PCR Nucleic Acids Symp Ser 42 59–60 Occurrence Handle1:CAS:528:DC%2BD3cXht1Cqt7c%3D Occurrence Handle10780378
E O'Neill H Humphreys (2005) ArticleTitleSurveillance of hospital water and primary prevention of nosocomial legionellosis: what is the evidence? J Hosp Infect 59 273–9 Occurrence Handle10.1016/j.jhin.2004.09.031 Occurrence Handle15749313
M Alary JR Joly (1992) ArticleTitleFactors contributing to the contamination of hospital water distribution systems by Legionellae J Infect Dis 165 565–9 Occurrence Handle1:STN:280:DyaK387ms1CnsA%3D%3D Occurrence Handle1538162
E Yabuuchi M Mori A Saito T Kishimoto S Yoshizawa M Arakawa et al. (1995) ArticleTitleAn outbreak of Pontiac fever due to Legionella pneumophila serogroup 7. II. Epidemiological aspects (in Japanese) Kansensyogaku Zassi 69 654–65 Occurrence Handle1:STN:280:DyaK2MzktFSltg%3D%3D
SC Redd FY Lin BS Fields J Biscoe BB Plikaytis P Powers et al. (1990) ArticleTitleA rural outbreak of Legionnaires' disease linked to visiting a retail store Am J Public Health 80 431–4 Occurrence Handle1:STN:280:DyaK3c7ps1CitQ%3D%3D Occurrence Handle2316763 Occurrence Handle10.2105/AJPH.80.4.431
M Koide N Arakaki A Saito (2001) ArticleTitleDistribution of Legionella longbeachae and other Legionellae in Japanese potting soils J Infect Chemother 7 224–7 Occurrence Handle10.1007/s101560170017 Occurrence Handle1:STN:280:DC%2BD38%2FovV2lsQ%3D%3D Occurrence Handle11810588
InstitutionalAuthorNameCenters for Disease Control (1997) ArticleTitleGuidelines for prevention of nosocomial pneumonia MMWR (Morb Mortal Wkly Rep) 46 1–79
InstitutionalAuthorNameCenters for Disease Control and Healthcare Infection Control Practices Advisory Committee (2004) ArticleTitleGuidelines for preventing health care associated pneumonia 2003 MMWR (Morb Mortal Wkly Rep) 53 1–36
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Fujimura, S., Oka, T., Tooi, O. et al. Detection of Legionella pneumophila serogroup 7 strain from bathwater samples in a Japanese hospital. J Infect Chemother 12, 105–108 (2006). https://doi.org/10.1007/s10156-005-0428-5
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10156-005-0428-5