Skip to main content
Log in

A new mathematical model for accurate quantification of cryogen spray cooling in cutaneous laser surgery using realistic boundary conditions

  • Original Article
  • Published:
Lasers in Medical Science Aims and scope Submit manuscript

Abstract

Laser dermatologic surgery is widely used for various skin diseases. Prior to the laser treatment, transient cryogen spray cooling (CSC) is employed to prevent unwanted thermal damage of skin tissue due to melanin absorption in the epidermis. Accurate quantification on the cooling effect of CSC is essential in the subsequent laser energy dosage prediction. Based on the existing experimental data, we present a new dynamic correlation in terms of non-dimensional heat convection coefficient as a function of the dimensionless time and dimensionless spatial location. The effects of transient spray cooling and the thermal properties of experimental substrate are included in the correlation. The heat transfer within the skin tissue is calculated by a heat conduction equation. Meanwhile, the dynamic correlation of heat convection coefficient is incorporated into the heat conduction equation as a convection boundary condition. Simulation results demonstrate that the correlation correctly reflects several important characteristics of CSC and the model predictions are in consistent with the experimental observations. Numerical results indicate that the CSC time duration should be short enough to maintain selective cooling in epidermis while long enough to avoid the non-uniform spatial cooling on skin surface. A shorter spray distance (for example z = 30 mm) is found to have better cooling effect than a longer spray distance (z = 60 mm). The dynamic correlation in terms of non-dimensional heat convection coefficient proposed in this study can be used in accurate quantification of the effect of CSC. Optimal cooling duration of 75–100 ms and short spray distance of 30 mm are recommended for CSC clinical application.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  1. Tunnell JW, Nelson JS, Torres JH, Anvari B (2000) Epidermal protection with cryogen spray cooling during high fluence pulsed dye laser irradiation: an ex vivo study. Lasers Surg Med 27:373–383

    Article  CAS  Google Scholar 

  2. Pikkula BM, Torres JH, Tunnell JW, Anvari B (2001) Cryogen spray cooling: effects of droplet size and spray density on heat removal. Lasers Surg Med 28:103–112

    Article  CAS  Google Scholar 

  3. Verkruysse W, Majaron B, Tanenbaum BS, Nelson JS (2000) Optimal cryogen spray cooling parameters for pulsed laser treatment of port wine stains. Lasers Surg Med 27:165–170

    Article  CAS  Google Scholar 

  4. Pikkula BM, Tunnell JW, Chang DW, Avari B (2004) Effects of droplet velocity, diameter, and film height on heat removal during cryogen spray cooling. Ann Biomed Eng 32:1131–1140

    Article  Google Scholar 

  5. Aguilar G, Majaron B, Verkruysse W, Zhou Y, Nelson JS, Lavernia EJ (2001) Theoretical and experimental analysis of droplet diameter, temperature, and evaporation rate evolution in cryogenic sprays. Int J Heat Mass Transf 44:3201–3211

    Article  Google Scholar 

  6. Aguilar G, Verkruysse W, Majaron B, Svaasand LO, Lavemia EJ, Nelson JS (2001) Measurement of heat flux and heat transfer coefficient during continuous cryogen spray cooling for laser dermatologic surgery. IEEE J Sel Top Quantum Electron 7(6):1013–1021

    Article  CAS  Google Scholar 

  7. Nelson JS, Milner TE, Anvari B, Tanenbaum BS, Kimel S, Svaasand LO, Jacques SL (1995) Dynamic epidermal cooling during pulsed laser treatment of port-wine stain: a new methodology with preliminary clinical evaluation. Arch Dermatol 131(6):695–700

    Article  CAS  Google Scholar 

  8. Nelson JS, Majaron B, Kelly KM (2000) Active skin cooling in conjunction with laser dermatologic surgery: methodology and clinical results. Semin Cutan Med Surg 19:253–266

    Article  CAS  Google Scholar 

  9. Nelson JS, Milner TE, Anvari B, Tanenbaum BS, Svaasand LO, Kimel S (1996) Dynamic epidermal cooling in conjunction with laser-induced photothermolysis of port wine stain blood vessels. Lasers Surg Med 19(2):224–229

    Article  CAS  Google Scholar 

  10. Edris A, Choi B, Aguilar G, Nelson JS (2003) Measurements of laser light attenuation following cryogen spray cooling spurt termination. Lasers Surg Med 32:143–147

    Article  Google Scholar 

  11. Choi B, Aguilar G, Vargas G, Welch AJ, Nelson S (2002) Dynamic measurements of laser light attenuation by cryogen film and frost formation. Proc SPIE 4609

  12. Aguilar G, Wang G-X, Nelson JS (2003) Effect of spurt duration on the heat transfer dynamics during cryogen spray cooling. Phys Med Biol 48:2169–2181

    Article  Google Scholar 

  13. Franco W, Liu J, Wang G-X, Nelson JS, Aguilar G (2005) Radial and temporal variations in surface heat transfer during cryogen spray cooling. Phys Med Biol 50:387–397

    Article  Google Scholar 

  14. Franco W, Liu J, Romero-Méndez R, Jia W, Nelson JS, Aguilar G (2007) Extent of lateral epidermal protection afforded by a cryogen spray against laser irradiation. Lasers Surg Med 39:414–421

    Article  Google Scholar 

  15. Li D, He YL, Liu YW, Wang GX (2007) Numerical analysis of cryogen spray cooling of skin in dermatologic laser surgery using realistic boundary conditions. 22th International Congress Refrigeration conference, BeiJing, China

  16. Li D, He YL, Wang GX, Xiao J, Liu YW (2007) Numerical analysis of cold injury of skin in cryogen spray cooling for dermatologic laser surgery. 2007 ASME International Mechanical Engineering Congress, Seattle, Washington

  17. Li D, He YL, Wang GX, Wang YX, Ying ZX (2013) A new model of selective photothermolysis to aid laser treatment of port wine stains. Chin Sci Bull 58:416–426

    Article  Google Scholar 

  18. Sun F, Aguilar G, Kelly KM, Wang G-X (2006) Thermal analysis for cryosurgery of nodular basal cell carcinoma, 2006 ASME international mechanical engineering congress and exposition, Chicago, Illinois, USA

Download references

Funding

This study was funded by National Natural Science Foundation of China (Grant No. 51976170) and International Science & Technology Cooperation Plan of Shaanxi Province (2016KW-024).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Dong Li or Bin Chen.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

No animal experiments were involved in this study.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wu, W., Li, D., Chen, B. et al. A new mathematical model for accurate quantification of cryogen spray cooling in cutaneous laser surgery using realistic boundary conditions. Lasers Med Sci 36, 1609–1617 (2021). https://doi.org/10.1007/s10103-020-03229-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10103-020-03229-2

Keywords

Navigation