The influence of zero value subtraction on the performance of a new laser fluorescence device for approximal caries detection

  • Original article
  • Published:
Lasers in Medical Science Aims and scope Submit manuscript

An Erratum to this article was published on 07 August 2008

Abstract

The aim of this study was to assess the influence of the zero value subtraction on the performance of laser fluorescence (LFpen) for approximal caries detection. Three areas (cuspal, middle and cervical) of both mesial and distal buccal surfaces of 78 permanent molars were assessed using both wedge-shaped (WDG) and tapered wedge-shaped (TWDG) tips. With the addition of the average, one cut-off value for each area was obtained and the performance was assessed. The areas under the receiver operating characteristics (ROC) curve, specificity, sensitivity and accuracy with and without the zero value subtraction were calculated. The McNemar test revealed a statistically significant difference for specificity at thresholds D1, D2 and D3 (WDG) and D1 and D2 (TWDG) when the zero value subtraction was not performed. Influence of the zero value subtraction on the LFpen performance was observed for approximal caries detection. However, when modified cut-off values were used, the zero value subtraction could be eliminated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Bader JD, Shugars DA (2004) A systematic review of the performance of a laser fluorescence device for detecting caries. J Am Dent Assoc 135:1413–1426

    Article  PubMed  Google Scholar 

  2. Braun A, Krause F, Jepsen S (2005) The influence of the calibration mode of a laser fluorescence device on caries detection. Caries Res 39:144–149

    Article  CAS  PubMed  Google Scholar 

  3. Mendes FM, Hissadomi M, Imparato JCP (2004) Effects of drying time and the presence of plaque on the in vitro performance of laser fluorescence in occlusal caries of primary teeth. Caries Res 38:104–108

    Article  CAS  PubMed  Google Scholar 

  4. Sheehy EC, Brailsford SR, Kidd EA, Beighton D, Zoitopoulos L (2001) Comparison between visual examination and a laser fluorescence system for in vivo diagnosis of occlusal caries. Caries Res 35:421–426

    Article  CAS  PubMed  Google Scholar 

  5. Lussi A, Reich E (2005) The influence of toothpastes and prophylaxis pastes on fluorescence measurements for caries detection. Eur J Oral Sci 113:141–144

    Article  CAS  PubMed  Google Scholar 

  6. Rodrigues JA, Vita TM, Cordeiro RCL (2008) In vitro evaluation of the influence of aluminum oxide air abrasion of pits and fissures on detection of occlusal caries lesions in primary teeth. Ped Dent (in press).

  7. Lussi A, Hellwig E (2006) Performance of a new laser fluorescence device for the detection of occlusal caries in vitro. J Dent 34:467–471

    Article  CAS  PubMed  Google Scholar 

  8. Lussi A, Hack A, Hug I, Heckenberg H, Megert B, Stich H (2006) Detection of approximal caries with a new laser fluorescence device. Caries Res 40:97–103

    Article  CAS  PubMed  Google Scholar 

  9. Lussi A, Imwinkelried S, Pitts NB, Longbotton C, Reich E (1999) Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro. Caries Res 33:261–266

    Article  CAS  PubMed  Google Scholar 

  10. Bamzahim M, Alijehani A, Shi XQ (2005) Clinical performance of DIAGNOdent in the detection of secondary carious lesions. Acta Odontol Scand 63:26–30

    Article  PubMed  Google Scholar 

  11. Alijehani A, Bamzahim M, Yousif MA, Shi XQ (2006) In vivo reliability of an infrared fluorescence method for quantification of carious lesions in orthodontic patients. Oral Health Prev Dent 4:145–150

    Google Scholar 

  12. Mendes FM, Oliveira E, Faria DLA, Nicolau J (2006) Ability of laser fluorescence device associated with fluorescent dyes in detecting and quantifying early smooth surface caries lesions. J Biomed Opt 11:0240071–00240076

    Article  Google Scholar 

  13. Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839–843

    Article  CAS  PubMed  Google Scholar 

  14. Hibst R, Paulus R, Lussi A (2001) A detection of occlusal caries by laser fluorescence: basic and clinical investigations. Med Laser Appl 16:295–213

    Article  Google Scholar 

  15. Braga MM, Mendes FM, Imparato JCP, Martins CR (2006) Effect of the calibration method of a laser fluorescence device for detecting occlusal caries in primary molars. Ped Dent 28:451–454

    Google Scholar 

  16. Kodaka T, Debari K, Kuroiwa M (1991) Mineral content of the innermost enamel in erupted human teeth. J Electron Microsc 40:19–23

    CAS  Google Scholar 

  17. Krause F, Braun A, Eberhard J, Jepsen S (2007) Laser fluorescence measurements compared to electrical resistance of residual dentine in excavated cavities in vitro. Caries Res 41:135–140

    Article  CAS  PubMed  Google Scholar 

  18. Shi XQ, Welander U, Angmar-Mansson B (2000) Occlusal caries detection with KaVo DIAGNOdent and radiography: an in vitro comparison. Caries Res 34:151–158

    Article  CAS  PubMed  Google Scholar 

  19. Pereira AC, Verdonschot EH, Huysmans MC (2001) Caries detection methods: can they aid decision making for invasive sealant treatment? Caries Res 35:83–89

    Article  CAS  PubMed  Google Scholar 

  20. Francescut P, Zimmerli B, Lussi A (2006) Influence of different storage methods on laser fluorescence values: a two-year study. Caries Res 40:181–185

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jonas de Almeida Rodrigues.

Additional information

An Erratum for this chapter can be found at http://dx.doi.org/10.1007/s10103-008-0602-y

Rights and permissions

Reprints and permissions

About this article

Cite this article

de Almeida Rodrigues, J., Hug, I. & Lussi, A. The influence of zero value subtraction on the performance of a new laser fluorescence device for approximal caries detection. Lasers Med Sci 24, 301–306 (2009). https://doi.org/10.1007/s10103-008-0549-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10103-008-0549-z

Keywords

Navigation