Abstract
Water is, for several reasons, by far the most widely used agent for extinguishing fires. Large quantities will turn to steam, but much will drain away with more or less ecotoxic effects on the ground and aquatic environments. Although this fire water run-off does not usually present a serious risk to the environment, it is reasonable to take precautions and to have quick in situ measures for predicting the likely consequences for, for example, a nearby mechanobiological, wastewater treatment plant. The enormous environmental damage caused by extinguishing waters in the past has focused attention on this environmental problem. From the detailed assessments of relevant parameters, it is demonstrated that product-related potency values may be capable of distinguishing between products. Some products tend to have toxic potencies that can be as much as almost four times higher than others. Risk assessments will not only reveal the routes by which major environmental damage might occur but also areas where fire precautions are inadequate. Special tasks must be allocated to the fire brigade: the earlier a fire can be tackled, the greater the chance of successfully extinguishing it and minimising the quantity of contaminated water. In this context, other active precautions such as fire detectors and sprinklers also help to minimise the ecotoxic effect of extinguishing waters. The primary fire-safety objective is to prevent any fires, rather than to deal with their consequences.
Similar content being viewed by others
References
The control of fire-water run off from CIMAH sites to prevent environmental damage, guidance note EH70, HSE health and safety executive, UK
Pohl KD, Wieneke A, Berger T, Voss S (1994) Analysis of contaminated extinguishing water (original German title: Analytik kontaminierter Löschwässer), WLB Wasser, Luft und Boden, 9/94
Wieneke A (1996) Development of concepts for the assessment and cleaning of contaminated extinguishing water (original German title: Erarbeitung von Konzepten zur Beurteilung und Reinigung kontaminierter Löschwässer), PhD Thesis, Wuppertal University
Wieneke A (1996) New findings concerning the analysis of contaminated extinguishing water (original German title: Neue Erkenntnisse zur Analytik kontaminierter Löschwässer), TÜ Bd. 37, No. 10
Sklorz M (1998) Decomposition experiments with plastics, generation and chemical-toxicological characterisation of extinguishing water and fire effluents (original German title: Verbrennungsexperimente mit Kunststoffen, Erzeugung und chemisch- toxikologische Charakterisierung von Löschwasser und Rauchgas), VDI Reihe 15: Umwelttechnik, Nr. 117
ISO 10093 (1994) Plastics—fire tests—standard ignition sources
ISO TR 9122: Toxicity testing of fire effluents
Stolp M (1976) The extinction of small wood crib fires by water. TNO, The Netherlands
Fuchs P, Seeger PG: A mathematical model for determining the amount of extinguishing water and comparison with experiments (original German title: Ein mathematisches Modell zur Bestimmung der Löschwassermenge und Vergleich mit Experimenten), vfdb-Zeitschrift, 1/81
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ecker, D., Pohl, K.D., Wieneke, A. et al. Assessment of extinguishing waters from intermediate-scale fire tests. Clean Techn Environ Policy 7, 127–132 (2005). https://doi.org/10.1007/s10098-004-0264-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10098-004-0264-9