Skip to main content
Log in

Comparison of BacT/ALERT 3D, Lowenstein-Jensen medium and Middlebrook 7H10/7H11 biplate for recovering mycobacteria from clinical specimens

  • Brief Report
  • Published:
European Journal of Clinical Microbiology and Infectious Diseases Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Tacquet A,Tisson F (1961) Résultat de l’isolement des mycobactéries par le lauryl-sulfate de sodium. Ann Inst Pasteur 100:676–680

    CAS  Google Scholar 

  2. Rogall T, Flohr T, Bottger EC (1990) Differentiation of Mycobacterium species by direct sequencing of amplified DNA. J Gen Microbiol 136:1915–1920

    CAS  PubMed  Google Scholar 

  3. Harmsen D, Rothganger J, Frosch M, Albert J (2002) RIDOM: Ribosomal differentiation of medical micro-organisms database. Nucleic Acids Res 30:416–417

    Article  CAS  PubMed  Google Scholar 

  4. Carricajo A, Fonsale N, Vautrin AC, Aubert G (2001) Evaluation of BacT/Alert 3D liquid culture system for recovery of mycobacteria from clinical specimens using sodium dodecyl (lauryl) sulfate-NaOH decontamination. J Clin Microbiol 39:3799–3800

    Article  CAS  PubMed  Google Scholar 

  5. Alcaide F, Gali N, Dominguez J, Berlanga P, Blanco S, Orus P, Martin R (2003) Usefulness of a new mycobacteriophage-based technique for rapid diagnosis of pulmonary tuberculosis. J Clin Microbiol 41:2867–2871

    Article  PubMed  Google Scholar 

  6. Angeby KA, Werngren J, Toro JC, Hedstrom G, Petrini B, Hoffner SE (2003) Evaluation of the BacT/ALERT 3D system for recovery and drug susceptibility testing of Mycobacterium tuberculosis. Clin Microbiol Infect 9:1148–1152

    Article  CAS  PubMed  Google Scholar 

  7. Piersimoni C, Scarparo C, Callegaro A, Tosi CP, Nista D, Bornigia S, Scagnelli M, Rigon A, Ruggiero G, Goglio A (2001) Comparison of MB/Bact alert 3D system with radiometric BACTEC system and Lowenstein-Jensen medium for recovery and identification of mycobacteria from clinical specimens: a multicenter study. J Clin Microbiol 39:651–657

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Adler.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Adler, H., Straub, C. & Frei, R. Comparison of BacT/ALERT 3D, Lowenstein-Jensen medium and Middlebrook 7H10/7H11 biplate for recovering mycobacteria from clinical specimens. Eur J Clin Microbiol Infect Dis 24, 499–500 (2005). https://doi.org/10.1007/s10096-005-1362-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10096-005-1362-2

Keywords

Navigation