Abstract:
A room temperature nuclear magnetic resonance force microscope (MRFM), fitted in a 1 tesla electromagnet, has been used to measure the nuclear spin relaxation of 1H in a micron-size (70 ng) crystal of ammonium sulfate. NMR sequences, combining both pulsed and continuous wave radio-frequency fields, have allowed us to measure mechanically T2 and T1, the transverse and longitudinal spin relaxation times. Because two spin species with different T1 values are measured in our 7 μm thick crystal, magnetic resonance imaging of their spatial distribution inside the sample section have been performed. To understand quantitatively the measured signal, we carefully study the influence of spin-lattice relaxation and non-adiabaticity of the continuous-wave sequence on the intensity and time dependence of the detected signal.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Received 23 February 2000
Rights and permissions
About this article
Cite this article
Klein, O., Naletov, V. & Alloul, H. Mechanical detection of nuclear spin relaxation in a micron-size crystal. Eur. Phys. J. B 17, 57–68 (2000). https://doi.org/10.1007/s100510070160