Closing behavior of the mechanical heart valve in a total artificial heart

  • ORIGINAL ARTICLE
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

 Recently, cavitation on the surface of mechanical heart valves has been studied as a cause of fractures occurring in implanted mechanical heart valves. The cause of cavitation in mechanical heart valve was investigated in both 25-mm Björk–Shiley and 25-mm Medtronic Hall valves. The closing events of these valves in the mitral position were simulated in an electrohydraulic total artificial heart with a stroke volume of 85 ml. The tests were conducted under physiologic pressures at heart rates of 60, 70, 80, and 90 beats/min with cardiac outputs of 4.5, 5.5, 6.4, and 7.5 l/min, respectively. The disk closing behavior was measured by a laser displacement sensor. The closing behaviors were investigated under various atrial and aortic pressures. In both valves, the duration of closing decreased with an increase in the cardiac output. The greater the amount of atrial pressure, the shorter the closing duration of both valves. The maximum closing velocity of the Medtronic Hall monostrut valve ranged from 0.8 to 0.9 m/s, and that of the Björk–Shiley monostrut valve ranged from 0.73 to 0.78 m/s. In both valves, the maximum closing velocities were less than the reported cavitation thresholds. This suggests that there should be no possibility of occurrence of cavitation in an electrohydraulic total artificial heart with mechanical heart valve.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: May 2, 2002 / Accepted: November 28, 2002

Present address: Department of Artificial Organs, Research Institute, National Cardiovascular Center, 5-7-1 Fujishiro-dai, Suita 565-5865, Japan Tel. +81-6-6833-5012; Fax +81-6-6835-5406 e-mail: hslee@ri.ncvc.go.jp

Correspondence to:H.S. Lee

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lee, H., Tsukiya, T., Homma, A. et al. Closing behavior of the mechanical heart valve in a total artificial heart. J Artif Organs 6, 0037–0041 (2003). https://doi.org/10.1007/s100470300006

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s100470300006

Navigation