Complex HeartWare left ventricular assist device infection treated with pump exchange: clinical alert for the driveline location

  • Case Report
  • Artificial Heart (Clinical)
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

Infection is a major complication in patients with a left ventricular assist device (LVAD). Once a driveline exit-site infection (DLI) reaches the LVAD component, LVAD exchange may become necessary for radical treatment, although clinical results are not satisfactory. In this report, we describe two cases of LVAD infection successfully treated with pump exchange. During LVAD support, the DLI extended into the pump pocket and the outflow graft despite aggressive surgical debridement and negative pressure wound therapy. These two patients required LVAD exchange for radical treatment, because the estimated waiting period for heart transplantation was at least more than 1 year. The LVAD exchange was performed through median re-sternotomy, and the infected HeartWare ventricular assist device (HVAD) was completely removed under cardiopulmonary bypass. Then, a new LVAD covered with the omentum flap was implanted. These two patients were successfully bridged to heart transplantation after 10 months and 2 years of support without recurrence of infection. These two cases may suggest that the driveline of the HVAD needs to be kept away from the outflow graft to prevent refractory outflow graft infection.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Kirklin JK, Pagani FD, Kormos RL, et al. Eighth annual INTERMACS report: special focus on framing the impact of adverse events. J Heart Lung Transplant. 2017;36:1080–6.

    Article  Google Scholar 

  2. Yoshioka D, Sakaniwa R, Toda K, et al. Relationship between bacteremia and hemorrhagic stroke in patients with continuous-flow left ventricular assist device. Circ J. 2018;82:448–56.

    Article  CAS  Google Scholar 

  3. John R, Aaronson KD, Pae WE, et al. Drive-line infections and sepsis in patients receiving the HVAD system as a left ventricular assist device. J Heart Lung Transplant. 2014;33:1066–73.

    Article  Google Scholar 

  4. Yuh DD, Albaugh M, Ullrich S, et al. Treatment of ventricular assist device driveline infection with vacuum-assisted closure system. Ann Thorac Surg. 2005;80:1493–5.

    Article  Google Scholar 

  5. Yoshioka D, Sakaniwa R, Toda K, et al. Relationship between bacteremia and hemorrhagic stroke in patients with continuousflow left ventricular assist device. Circ J. 2018;82:448–56.

    Article  CAS  Google Scholar 

  6. Rogers JG, Pagani FD, et al. Intrapericardial left ventricular assist device for advanced heart failure. N Engl J Med. 2017;376:451–60.

    Article  Google Scholar 

  7. Yoshioka D, Toda K, Sakaguchi T, et al. Initial report of bridge to recovery in a patient with DuraHeart LVAD. J Artif Organs. 2013;16:386–8.

    Article  Google Scholar 

  8. Abicht T, Gordon R, Meehan K, et al. Complex HeartMate II infection treated with pump exchange to HeartWare HVAD. ASAIO J. 2013;59:188–92.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshiki Sawa.

Ethics declarations

Conflict of interest

The authors declare that they have no conflicts of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Domae, K., Toda, K., Yoshioka, D. et al. Complex HeartWare left ventricular assist device infection treated with pump exchange: clinical alert for the driveline location. J Artif Organs 24, 377–381 (2021). https://doi.org/10.1007/s10047-020-01245-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-020-01245-1

Keywords

Navigation