Untwist the twist: instant hemodynamic improvement in known HeartMate 3 complication

  • Case Report
  • Artificial Heart (Clinical)
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

The HeartMate 3 [HM3 (Abbott, Abbott Park, Illinois)] is a left-ventricular assist device (LVAD) with excellent clinical results. Outflow graft occlusion as a complication secondary to outflow graft twisting was reported to occur in 1.6% within the MOMENTUM 3 trial. The anti-twist metal clip or modified bend relief is made to prevent this complication currently, however, there remain large numbers of early implanted HM3 which may develop this complication. There are limited reports illustrating diagnosis, surgical repair, and post-repair hemodynamic changes of these complications. Thus, we present a case of successful diagnosis and surgical repair of an outflow graft twist. Simple procedure through thoracotomy without cardiopulmonary bypass provides significant immediate hemodynamic improvement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Mehra MR, Goldstein DJ, Uriel N, Cleveland JC, Yuzefpolskaya M, Salerno C, et al. Two-year outcomes with a magnetically levitated cardiac pump in heart failure. N Engl J Med. 2018;378:1386–95.

    Article  Google Scholar 

  2. Mehra MR, Salerno C, Naka Y, Uriel N, Cleveland JC, Horstmanshof D, et al. A tale of the twist in the outflow graft: An analysis from the MOMENTUM 3 trial. J Heart Lung Transplant. 2018;37:1281–4.

    Article  Google Scholar 

  3. Kagan V, Mehta C, Michel E, Ward A, Jivan A, Ricciardi M, et al. Approaches to repairing outflow graft stenosis in left ventricular assist devices. J Heart Lung Transplant. 2019;38:S367.

    Article  Google Scholar 

  4. Grüger T, Kaufmann F, Dreysse S, Falk V, Krabatsch T, Potapov E. Late post-pump blood flow obstruction in a novel left ventricular assist device: the unusual case of a twisted outflow graft. J Thorac Cardiovasc Surg. 2018;155:e33–5.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Camille E. Hironaka or Masashi Kawabori.

Ethics declarations

Conflict of interest

The authors have no conflicts of interest to disclose.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Su, L., Hironaka, C.E., Chen, F.Y. et al. Untwist the twist: instant hemodynamic improvement in known HeartMate 3 complication. J Artif Organs 24, 365–367 (2021). https://doi.org/10.1007/s10047-020-01220-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-020-01220-w

Keywords

Navigation