Continuous-flow total artificial heart: hemodynamic and pump-related changes associated with posture in a chronic calf model

  • Brief Communication
  • Artificial Heart (Basic)
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

This study aimed to evaluate the effects of posture (sitting [lying down]/standing) on hemodynamic and pump-related parameters in calves implanted with our institution’s continuous-flow total artificial heart (CFTAH). These parameters were analyzed with posture information in four calves that had achieved the intended 14-, 30-, or 90-day durations of implantation. In each animal, postoperative hourly data gathered throughout the study were used to compare average values with the animal sitting vs. standing. Pump flow became significantly higher in the standing than sitting position at the same pump speed (standing 7.9 ± 0.8, sitting 7.4 ± 1.0 L/min, p = 0.028). Systemic vascular resistance (SVR) and aortic pressure (AoP) were significantly lower in the standing than sitting position (SVR standing 779 ± 145, sitting 929 ± 206 dyne s/cm5, p = 0.027; AoP standing 93 ± 7, sitting 103 ± 7 mm Hg, p < 0.001). No substantial change occurred in pulmonary vascular resistance (PVR) or pulmonary arterial pressure (PAP) with posture (PVR standing 161 ± 39, sitting 164 ± 48 dyne s/cm5, p = 0.639; PAP standing 32 ± 3, sitting 33 ± 4 mm Hg, p = 0.340). Posture affected some hemodynamic and pump-related parameters in calves with CFTAH, with implications for patients with implanted pumps.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

References

  1. Karimov JH, Moazami N, Kobayashi M, Sale S, Such K, Byram N, et al. First report of 90-day support of two calves with a continuous-flow total artificial heart. J Thorac Cardiovasc Surg. 2015;150:687-93.e1.

    Article  PubMed  Google Scholar 

  2. Kobayashi M, Horvath DJ, Mielke N, Shiose A, Kuban B, Goodin M, et al. Progress on the design and development of the continuous-flow total artificial heart. Artif Organs. 2012;36:705–13.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Hainsworth R, Al-Shamma YM. Cardiovascular responses to upright tilting in healthy subjects. Clin Sci (London, England: 1979). 1988;74:17–22.

    Article  CAS  Google Scholar 

  4. Streicher W, Misner JE, Bloomfield DK, Massey BH. Hemodynamic responses to positional change in habitually physically active and inactive older men. J Am Geriatr Soc. 1988;36:795–800.

    Article  CAS  PubMed  Google Scholar 

  5. Sprangers RL, Wesseling KH, Imholz AL, Imholz BP, Wieling W. Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance. J Appl Physiol (Bethesda, Md: 1985). 1991;70:523–30.

    Article  CAS  Google Scholar 

  6. Bedford TG, Dormer KJ. Arterial hemodynamics during head-up tilt in conscious dogs. J Appl Physiol (Bethesda, Md : 1985). 1988;65:1556–62.

    Article  CAS  Google Scholar 

  7. Abboud FM, Eckberg DL, Johannsen UJ, Mark AL. Carotid and cardiopulmonary baroreceptor control of splanchnic and forearm vascular resistance during venous pooling in man. J Physiol. 1979;286:173–84.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Fukamachi K, Fukumura F, Kiraly RJ, Massiello AL, Chen JF, Himley S, et al. Hemodynamic changes with posture in calves with total artificial heart. ASAIO J (American Society for Artificial Internal Organs : 1992). 1993;39:M419–22.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

This work was supported with federal funding obtained from the National Heart, Lung and Blood Institute, National Institutes of Health (Bethesda, Maryland, USA), under Grant 5R01HL096619 (to KF).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jamshid H. Karimov.

Ethics declarations

Conflict of interest

David J. Horvath and Barry D. Kuban are co-inventors of the device. The technology was licensed to Cleveland Heart, Inc., a Cleveland Clinic spin-off company. All other authors have nothing to disclose with regard to commercial support.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kado, Y., Byram, N., Miyamoto, T. et al. Continuous-flow total artificial heart: hemodynamic and pump-related changes associated with posture in a chronic calf model. J Artif Organs 22, 256–259 (2019). https://doi.org/10.1007/s10047-019-01105-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-019-01105-7

Keywords

Navigation