Abstract
Infection is a serious potential complication after left ventricular assist device (LVAD) implantation. In general, infection of the device pocket, with device exposure, should be managed by early device removal and heart transplantation. However, because of the small number of donors in Japan, accelerating access to heart transplantation is often difficult and the LVAD can be widely exposed during the waiting period. We report our experience of successful heart transplantation in a patient with a widely exposed LVAD with pocket infection. A 48-year-old man suffered from heart failure due to idiopathic dilated cardiomyopathy. An LVAD was implanted, but postoperative infection led to blood pump exposure. Heart transplantation was performed 4 months after LVAD exposure, at which time the epigastric skin defect measured 14 × 8 cm. The skin defect could not be closed after heart transplantation, so it was covered by an omental flap with split-thickness skin grafts. 7 days postoperatively, the peritoneal suture broke and the intestinal tract prolapsed outside the body. Reintroduction of the prolapsed intestinal tract and deep inferior epigastric artery perforator (DIEP) flap coverage of the omental flap were performed. The postoperative course was uneventful. There have been no reports of the management of wide skin defects in the presence of infection when heart transplantation is performed. Omental flap placement was useful for controlling long-lasting infection. An omental flap placed in a patient with a wide epigastric skin defect should be covered by durable skin flap, such as a DIEP flap, to avoid intestinal prolapse.
Similar content being viewed by others
References
Fukushima N, Ono M, Saiki Y, Sawa Y, Nunoda S, Isobe M. Registry report on heart transplantation in Japan (June 2016). Circ J. 2017;81:298–303.
Baddour LM, Bettmann MA, Bolger AF, Epstein AE, Ferrieri P, Gerber M, et al. Nonvalvular cardiovascular device-related infections. Circulation. 2003;108:2015–31.
Roussel LO, Khouri JS, Christiano JG. Pedicled flap closure as an adjunct for infected ventricular assist devices. Ann Plast Surg. 2017;78:712–6.
Wong C, Saint-Cyr M, Mojallal A, Schau T, Bailey SH, Myers S, et al. Perforasomes of the DIEP flap: vascular anatomy of the lateral versus medial row perforators and clinical implications. Plast Reconstr Surg. 2010;125:772–82.
Toda K, Sawa Y. Clinical management for complications related to implantable LVAD use. Gen Thorac Cardiovasc Surg. 2015;63:1–7.
Pieri M, Scandroglio AM, Muller M, Pergantis P, Kretzschmar A, Kaufmann F, et al. Surgical management of driveline infections in patients with left ventricular assist devices. J Card Surg. 2016;31:765–71.
Jacoby A, Stranix JT, Cohen O, Louie E, Balsam LB, Levine JP. Flap coverage for the treatment of exposed left ventricular assist device (LVAD) hardware and intractable LVAD infections. J Card Surg. 2017;32:732–7.
Matsuda K, Nishibayashi A, Toda K, Fujiwara T, Fukai M, Yoshioka D, et al. Covering implantable left ventricular assist device (DuraHeart®) with free flap. J Artif Organs. 2015;18:114–9.
Funding
No funding support was received for this case report.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article