Skip to main content
Log in

Implantation of a Jarvik 2000 left ventricular assist device as a bridge to eligibility for refractory heart failure with renal dysfunction

  • Case Report
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

A 55-year-old man, who previously underwent surgical ventricular restoration and mitral valve surgery, was referred to our department for management of refractory heart and multiple organ failure. At the time of admission to our hospital, he could not be registered as a candidate for heart transplantation because of severe renal failure with a serum creatinine level of 4.6 mg/dl. We considered that he was a marginal candidate for heart transplantation; thus, it was essential to understand the etiology of renal failure and estimate whether it was reversible. Cardiac catheterization revealed poor hemodynamic function with a systemic pressure of 107/60 mmHg, cardiac index of 2.5 l/min/m2, and pulmonary artery pressure of 63/27 mmHg, despite intense medical treatment. Contrary to biochemical examination findings of blood, renal biopsy findings showed no significant glomerular abnormality. Furthermore, the severity of tubular atrophy and interstitial fibrosis in the cortex was mild. These pathological findings suggested that the renal dysfunction in this case was possibly attributable to a hemodynamic factor. His symptoms gradually deteriorated despite an increasing dose of inotropic support; thus, we planned implantation of a Jarvik 2000 axial-flow pump (Jarvik Heart Inc., New York, NY, USA) as a bridge to eligibility, and informed consent was obtained. Because of a tight adhesion on the anterior wall, we placed the device on the lateral wall of the left ventricle, making sure not to direct the pump at the septum. Postoperatively, the implantable left ventricular assist device provided relief from heart failure symptoms as well as recovery of renal function, with serum the creatinine level at 1.2 mg/dl, which allowed the patient to become an appropriate candidate for heart transplantation. At an 18-month follow-up examination, his status was uneventful, and he is now at home awaiting heart transplantation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Hillege HL, Nitsch D, Pfeffer MA, Swedberg K, McMurray JJ, Yusuf S, Granger CB, Michelson EL, Ostergren J, Cornel JH, de Zeeuw D, Pocock S, van Veldhuisen DJ, et al. Renal function as a predictor of outcome in a broad spectrum of patients with heart failure. Circulation. 2006;113:671–8.

    Article  PubMed  Google Scholar 

  2. Haj-Yahia S, Birks EJ, Rogers P, Bowles C, Hipkins M, George R, Amrani M, Petrou M, Pepper J, Dreyfus G, Khaghani A. Midterm experience with the Jarvik 2000 axial flow left ventricular assist device. J Thorac Cardiovasc Surg. 2007;134:199–203.

    Article  PubMed  Google Scholar 

  3. Frazier OH, Delgado RM. Mechanical circulatory support for advanced heart failure: where does it stand in 2003? Circulation. 2003;108:3064–8.

    Article  PubMed  CAS  Google Scholar 

  4. Deng MC, Edwards LB, Hertz MI, Rowe AW, Keck BM, Kormos R, Naftel DC, Kirklin JK. Mechanical Circulatory Support Device Database of the International Society for Heart and Lung Transplantation: second annual report 2004. J Heart Lung Transplant. 2004;23:1027–34.

    Article  PubMed  Google Scholar 

  5. Copeland JG, Smith RG, Arabia FA, Nolan PE, Sethi GK, Tsau PH, McClellan D, Slepian MJ, CardioWest Total Artificial Heart Investigators, et al. Cardiac replacement with a total artificial heart as a bridge to transplantation. N Engl J Med. 2004;351:859–67.

    Article  PubMed  CAS  Google Scholar 

  6. Frazier OH, Myers TJ, Gregoric ID, Khan T, Delgado R, Croitoru M, Miller K, Jarvik R, Westaby S. Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system. Circulation. 2002;105:2855–60.

    Article  PubMed  CAS  Google Scholar 

  7. James KB, McCarthy PM, Jaalouk S, Bravo EL, Betkowski A, Thomas JD, Nakatani S, Fouad-Tarazi FM. Plasma volume and its regulatory factors in congestive heart failure after implantation of long-term left ventricular assist devices. Circulation. 1996;93:1515–9.

    PubMed  CAS  Google Scholar 

  8. Maschio G, Alberti D, Janin G, Locatelli F, Mann JF, Motolese M, Ponticelli C, Ritz E, Zucchelli P. Effect of the angiotensin-converting-enzyme inhibitor benazepril on the progression of chronic renal insufficiency. N Engl J Med. 1996;334:939–45.

    Article  PubMed  CAS  Google Scholar 

  9. Sugiura T, Wada A. Resistive index predicts renal prognosis in chronic kidney disease. Nephrol Dial Transplant. 2009;24:2780–5.

    Article  PubMed  Google Scholar 

  10. Sandner SE, Zimpfer D, Zrunek P, Rajek A, Schima H, Dunkler D, Grimm M, Wolner E, Wieselthaler GM. Renal function and outcome after continuous flow left ventricular assist device implantation. Ann Thorac Surg. 2009;87:1072–8.

    Article  PubMed  Google Scholar 

  11. Butler J, Geisberg C, Howser R, Portner PM, Rogers JG, Deng MC, Pierson RN 3rd. Relationship between renal function and left ventricular assist device use. Ann Thorac Surg. 2006;81:1745–51.

    Article  PubMed  Google Scholar 

  12. Klag MJ, Whelton PK, Randall BL, Neaton JD, Brancati FL, Ford CE, Shulman NB, Stamler J. Blood pressure and end-stage renal disease in men. N Engl J Med. 1996;334:13–8.

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgments

This study is supported by the Health and Labour Sciences Research Grants, Research on intractable diseases.

Conflict of interest

There are no conflicts of interest to report.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Satoshi Kainuma or Yoshiki Sawa.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kainuma, S., Sakaguchi, T., Saito, S. et al. Implantation of a Jarvik 2000 left ventricular assist device as a bridge to eligibility for refractory heart failure with renal dysfunction. J Artif Organs 15, 83–86 (2012). https://doi.org/10.1007/s10047-011-0602-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-011-0602-8

Keywords

Navigation