Outcomes of midterm circulatory support by left ventricular assist device implantation with descending aortic anastomosis

  • Original Article
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

For some patients undergoing left ventricular assist device (LVAD) implantation, the perfusion tube is anastomosed to the descending aorta instead of the currently more prevalently used ascending aorta. Purpose of this study was to assess retrospectively the outcomes of LVAD patients with descending aortic anastomosis. Between March 2007 and March 2010, six patients underwent LVAD implantation with descending aortic anastomosis with Toyobo or Jarvik 2000 LVAD at our institute. Their average circulatory support time was 434 (range 82–751) days. Both types of LVAD afforded adequate circulatory support, and inotrope treatment and mechanical ventilation were discontinued relatively early. Echocardiograms of the three patients with Jarvik 2000 LVAD revealed antegrade flow in the ascending aorta during the intermittent low-speed period. Among them, one patient developed infarction in the right brain hemisphere because of thromboembolism, whereas another patient developed pneumonia in the left lung followed by a lethal systemic infection. One patient on Toyobo LVAD support reached heart transplantation without morbidity. Another patient implanted with Toyobo LVAD, whose left ventricular function was too poor to generate forward flow through aortic valve, developed thrombus in the ascending aorta. No embolic events were observed in the organs below the diaphragm. In conclusion, descending aortic anastomosis of the perfusion tube can be used for LVAD implantation for some patients, but considerable risks of morbidities, including thromboembolic events and/or infection, should be recognized.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Litwak KN, Koenig SC, Tsukui H, Kihara S, Wu Z, Pantalos GM. Effects of left ventricular assist device support and outflow graft location upon aortic blood flow. ASAIO J. 2004;50:432–7.

    Article  PubMed  Google Scholar 

  2. Pierson RN 3rd, Howser R, Donaldson T, Merrill WH, Dignan RJ, Drinkwater DC Jr, Christian KG, Butler J, Chomsky D, Wilson JR, Clark R, Davis SF. Left ventricular assist device implantation via left thoracotomy: alternative to repeat sternotomy. Ann Thorac Surg. 2002;73:997–9.

    Article  PubMed  Google Scholar 

  3. Haj-Yahia S, Birks EJ, Rogers P, Bowles C, Hipkins M, George R, Amrani M, Petrou M, Pepper J, Dreyfus G, Khaghani A. Midterm experience with the Jarvik 2000 axial flow left ventricular assist device. J Thorac Cardiovasc Surg. 2007;134:199–203.

    Article  PubMed  Google Scholar 

  4. DiGiorgi PL, Smith DL, Naka Y, Oz MC. In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices. J Heart Lung Transplant. 2004;23:186–92.

    Article  PubMed  Google Scholar 

  5. Tuzun E, Gregoric ID, Conger JL, Golden K, Jarvik R, Frazier OH, Kadipasaoglu KA. The effect of intermittent low speed mode upon aortic valve opening in calves supported with a Jarvik 2000 axial flow device. ASAIO J. 2005;51:139–43.

    Article  PubMed  Google Scholar 

  6. Cohn WE, Fikfak V, Gregoric ID, Frazier OH. Retention of left ventricular assist device outflow grafts after transplantation. J Heart Lung Transplant. 2008;27:865–8.

    Article  PubMed  Google Scholar 

  7. Holman WL, Kirklin JK, Naftel DC, Kormos RL, Desvign-Nickens P, Camacho MT, Ascheim DD. Infection after implantation of pulsatile mechanical circulatory support devices. J Thorac Cardiovasc Surg. 2010;139(6):1632–6.

    Article  PubMed  Google Scholar 

  8. Svensson LG, Blackstone EH, Rajeswaran J, Sabik JF, Lytle BW 3rd, Gonzalez-Stawinski G, Varvitsiotis P, Banbury MK, McCarthy PM, Pettersson GB, Cosgrove DM. Does the arterial cannulation site for circulatory arrest influence stroke risk? Ann Thorac Surg. 2004;78:1274–84. discussion -84.

    Article  PubMed  Google Scholar 

  9. Lakew F, Pasek P, Zacher M, Diegeler A, Urbanski PP. Femoral versus aortic cannulation for surgery of chronic ascending aortic aneurysm. Ann Thorac Surg. 2005;80:84–8.

    Article  PubMed  Google Scholar 

  10. Swartz MT, Lowdermilk GA, Moroney DA, McBride LR. Ventricular assist device support in patients with mechanical heart valves. Ann Thorac Surg. 1999;68:2248–51.

    Article  CAS  PubMed  Google Scholar 

  11. Omoto T, Minami K, Muramatsu T, Kyo S, Korfer R. Pseudoaneurysm after heart transplantation with history of LVAD driveline infection. Ann Thorac Surg. 2001;72:263–4.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Kan Nawata or Takashi Nishimura.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nawata, K., Nishimura, T., Kyo, S. et al. Outcomes of midterm circulatory support by left ventricular assist device implantation with descending aortic anastomosis. J Artif Organs 13, 197–201 (2010). https://doi.org/10.1007/s10047-010-0521-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-010-0521-0

Keywords

Navigation