Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta

  • Original Article
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

The current design of the bileaflet valve, the leaflets of which open outside first, differs significantly from the natural valve whose leaflets open center first. This difference generates a completely different flow field in the bileaflet valve compared to that in the natural heart valve. In a previous study, it was demonstrated that the valve design greatly affects the aortic flow field as well as the circulatory flow inside sinuses of Valsalva, using saline solution as a working fluid. A limited discussion on the turbulence flow field that could be generated by the valve was provided. In this continuation of that study, therefore, a dynamic PIV study was conducted to analyze the influence of the heart valve design on the aortic flow field, and particularly on the turbulent profile. This study also aimed to determine the influence of the viscosity of the testing fluid. Three bileaflet prostheses—the St. Jude Medical (SJM), the On-X, and the MIRA valves—were tested under pulsatile flow conditions. Flow through the central orifice of the SJM valve was slower than that through the newer designs. The newer designs tend to show strong flow through all orifices. The On-X valve generates simple jet-type flow while the MIRA valve with circumferentially curved leaflets generates a strong but three-dimensionally diffuse flow, resulting in a more complex flow field downstream of the aortic valve with higher turbulence. A 180° orientation that is more popular clinically seems to provide a less diffuse flow than a 90° orientation. The effect of increasing the viscosity was found to be an increase in the flow velocity through the central orifice and a more organized flow field for all of the valves tested.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. Hufnagel CA, Harvey WP, Rabil PJ, McDermott TF. Surgical correction of aortic insufficiency. Surgery. 1954;35:673–83.

    CAS  PubMed  Google Scholar 

  2. Starr A, Edwards ML, McCord CW, Griswold HE. Aortic replacement clinical experience with semirigid ball-valve prosthesis. Circulation. 1963;27:779–83.

    Google Scholar 

  3. Ramstack JM, Zuckerman L, Mockros LF. Shear-induced activation of platelets. J Biomech. 1979;12:113–25.

    Article  CAS  PubMed  Google Scholar 

  4. Krishnan S, Udaykumar HS, Marshall JS, Chandran KB. Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure. Ann Biomed Eng. 2006;34:1519–34.

    Article  CAS  PubMed  Google Scholar 

  5. Akutsu T, Fukuda T. Time-resolved particle image velocimetry and laser Doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses. J Artif Organs. 2005;8:171–83.

    Article  PubMed  Google Scholar 

  6. Modi VJ, Bishop WF, Akutsu T. Unsteady fluid dynamics of three contemporary heart valves using a two-component LDA system. J Artif Organs. 1991;14:103–7.

    Google Scholar 

  7. Akutsu T, Modi VJ. Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two-component laser Doppler anemometer system. J Artif Organs. 1997;21:1110–20.

    CAS  Google Scholar 

  8. Akutsu T, Saito J, Imai R, Suzuki T, Cao XD. Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses. J Artif Organs. 2008;11:75–90.

    Article  PubMed  Google Scholar 

  9. Du Plessis LA, Marchand P. The anatomy of the mitral valve and its associated structures. Thorax. 1964;19:221–7.

    Article  CAS  Google Scholar 

  10. Suzuki T, Saito J, Akutsu T. Flow field study of prosthetic heart valves using dynamic PIV; effect of testing fluid viscosity. In: Proc 20th JSME Bioeng Conf 2008, Tokyo, Japan, 25–26 Jan 2008, 07-49:265–266 (in Japanese).

  11. Akutsu T, Saito J. Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses. J Artif Organs. 2006;9:165–78.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Toshinosuke Akutsu.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Akutsu, T., Matsumoto, A. Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta. J Artif Organs 13, 207–217 (2010). https://doi.org/10.1007/s10047-010-0519-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-010-0519-7

Keywords

Navigation