Abstract
This study aimed to map the elasticity of a natural artery at the micron level by using a tactile mapping system (TMS) that was recently developed for characterization of the stiffness of tissue slices. The sample used was a circumferential section (thickness, approximately 1 mm) of a small-caliber porcine artery (diameter, approximately 3 mm). Elasticity was measured with a probe of diameter 1 μm and a spatial resolution of 2 μm at a rate of 0.3 s per point, without significant sample invasion. Topographical measurements were also performed simultaneously. Wavy regions of high elasticity, layered in the circumferential direction, were measured at the tunica media, which was identified as an elastin-rich region. The Young’s modulus of the elastin-rich region in the media was 50.8 ± 13.8 kPa, and that of the elastin-rich region of the lamina elastica interna was 69.0 ± 12.8 kPa. Both these values were higher than the Young’s modulus of the other regions in the media, including smooth muscle cells and collagen fibrils (17.0 ± 9.0 kPa). TMS is simple and inexpensive to perform and allows observation of the distribution of the surface elastic modulus at the extracellular matrix level in vascular tissue. TMS is expected to be a powerful tool in evaluation of the maturation and degree of reconstruction in the development of tissue-engineered or artificial tissues and organs.
Similar content being viewed by others
References
Humphrey JD. Mechanics of the arterial wall: review and directions. Crit Rev Biomed Eng 1995;23:1–162
Binnig G, Quate DF, Gerber C. Atomic force microscope. Phys Rev Lett 1986;56:930–933
Lieber SC, Aubry N, Pain J, Diaz G, Kim S, Vatner SF. Aging increases stiffness of cardiac myocytes measured by atomic force microscopy nanoidentation. Am J Physiol Heart Circ Physiol 2004;287:H645–H651
Ziebarth NM, Wojcikiewiez EP, Manns F, Moy VT, Parel J. Atomic force microscopy measurements of lens elasticity in monkey eyes. Mol Vis 2007;13:504–510
Stolz M, Raiteri R, Daniels AU, VanLandingham MR, Baschong W, Aebi U. Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy. Biophys J 2004;86:3269–3283
Jacot JG, Dianis S, Schnall J, Wong JY. A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues. J Biomed Mater Res 2006;79A:485–494
Miyazaki H, Hasegawa Y, Hayashi K. A newly designed tensile tester for cells and its application to fibroblasts. J Biomech 2000;33:97–104
Murayama Y, Omata S, Constantinou CE. Micromechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech 2004;37:67–72
Eltaib MEH, Hewit JR. Tactile sensing technology for minimal access surgery — a review. Mechatronics 2003;13:1163–1177
Kusaka K, Harihara Y, Torzilli, Kubota K, Takayama T, Makuuchi M, Mori M, Omata S. Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve for hepatectomy. J Am Coll Surg 2000;1:47–53
Murayama Y, Constantinou CE, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sensor Actuat A 2005;120:543–549
Watanabe T, Kanda K, Ishibashi-Ueda H, Yaku H, Nakayama Y. Development of biotube vascular grafts incorporating cuffs for easy implantation. J Artif Organs 2007;10:10–15
Sakai O, Kanda K, Ishibashi-Ueda H, Takamizawa K, Ametani A, Yaku H, Nakayama Y. Development of the wing-attached rod for acceleration of “biotube” vascular grafts fabrication in vivo. J Biomed Mater Res 2007;83:240–247
Hayashida K, Kanda K, Yaku H, Ando J, Nakayama Y. Development of an in vivo tissue-engineered autologous heart valve (the biovalve): preparation of prototype model. J Thorac Cardiovasc Surg 2007;134:152–159
Hayashida K, Kanda K, Oie T, Okamoto Y, Sakai O, Watanabe T, Ishibashi-Ueda H, Onoyama M, Tajikawa T, Ohba K, Yaku H, Nakayama Y. In vivo tissue-engineered valved conduit with designed molds and laser-processed scaffold. J Cardiovasc Nurs 2008;23:61–64
Hayashida K, Kanda K, Oie T, Okamoto Y, Ishibashi-Ueda H, Onoyama M, Tajikawa T, Ohba K, Yaku H, Nakayama Y. Architecture of an in vivo-tissue engineered autologous conduit “biovalve.” J Biomed Mater Res B 2008;86(1):1–8
Murayama Y, Omata S. Fabrication of micro-tactile sensor for the measurement of micro-scale local elasticity. Sensor Actuat A 2004;109:202–207
Omata S, Terunuma Y. New tactile sensor like the human hand and its application. Sensor Actuat A 1992;3:9–15
Gosline J, Lillie M, Carrington E, Guerette P, Ortlepp C, Savage K. Elastic proteins: biological roles and mechanical properties. Phil Trans R Soc Lond B 2002;357:121–132
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Oie, T., Murayama, Y., Fukuda, T. et al. Local elasticity imaging of vascular tissues using a tactile mapping system. J Artif Organs 12, 40–46 (2009). https://doi.org/10.1007/s10047-008-0440-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10047-008-0440-5