Abstract
To estimate the length of the aorta from the subclavian artery to the renal artery in Japanese adults, its length was measured on computed tomographic (CT) images. Data from a total of 110 patients without aortic or aortic valvular diseases (54 men, 56 women) who had undergone 7-mm-slice-interval CT examination of the entire aorta was analyzed in this study. The length of the aorta was found to be 214.1 ± 20.7 mm and showed a positive correlation with height (r = 0.664). Especially, the length of the aorta in male patients was correlated with body mass, i.e., height, weight, and body surface area. From these results, it appears that the majority of commercially available intra-aortic balloon catheters are too long for use in the Japanese population. It is concluded that a shorter, more suitable catheter should be made available for safe use in Japanese patients.
Similar content being viewed by others
References
JJ Ferguson SuffixIII M Cohen RJ Freedman et al. (2001) ArticleTitleThe current practice of intra-aortic balloon counterpulsation: results from the benchmark registry J Am Coll Cardiol 38 1456–1461 Occurrence Handle11691523 Occurrence Handle10.1016/S0735-1097(01)01553-4
KS Naunheim MT Swartz DG Pennington et al. (1992) ArticleTitleIntra-aortic balloon pumping in patients requiring cardiac operations. Risk and analysis and long term follow-up J Thorac Cardiovasc Surg 104 1654–1661 Occurrence Handle1453730 Occurrence Handle1:STN:280:ByyD1cnhtFQ%3D
JM Alvarez R Gates D Rowe et al. (1992) ArticleTitleComplications from intra-aortic balloon counterpulsation Eur J Cardiothorac Surg 6 530–535 Occurrence Handle1389234 Occurrence Handle10.1016/1010-7940(92)90003-G Occurrence Handle1:STN:280:ByyD3c7itlY%3D
ZS Meharwal N Trehan (2002) ArticleTitleVascular complications of intra-aortic balloon insertion in patients undergoing coronary revascularization: analysis of 911 cases Eur J Cardiothorac Surg 21 741–747 Occurrence Handle11932177 Occurrence Handle10.1016/S1010-7940(02)00034-9
H Sirbu T Busch I Aleksic et al. (2000) ArticleTitleIschemic complications with intra-aortic balloon counterpulsation: incidence and management Cardiovasc Surg 8 66–71 Occurrence Handle10661706 Occurrence Handle10.1016/S0967-2109(99)00087-3 Occurrence Handle1:STN:280:DC%2BD3c7isFenug%3D%3D
OE Arafa TH Pederson JL Svennevig et al. (1999) ArticleTitleVascular complications of the intraaortic balloon pump in patients undergoing open heart operations: 15-year experience Ann Thorac Surg 67 645–651 Occurrence Handle10215204 Occurrence Handle10.1016/S0003-4975(98)01272-7 Occurrence Handle1:STN:280:DyaK1M3jtVSnsQ%3D%3D
DJ Mackenzie WH Wagner DA Kulber et al. (1992) ArticleTitleVascular complications of intra-aortic balloon pump Am J Surg 164 517–521 Occurrence Handle1443380 Occurrence Handle10.1016/S0002-9610(05)81192-4 Occurrence Handle1:STN:280:ByyD2s3msFY%3D
DE Gutfinger RA Ott M Miller et al. (1999) ArticleTitleAggressive preoperative use of intra-aortic balloon pump in elderly patients undergoing coronary artery bypass grafting Ann Thorac Surg 67 610–613 Occurrence Handle10215196 Occurrence Handle10.1016/S0003-4975(98)01201-6 Occurrence Handle1:STN:280:DyaK1M3jtVSgtw%3D%3D
H Shin R Yozu T Sumida et al. (2000) ArticleTitleAcute ischemic hepatic failure resulting from intraaortic balloon pump malposition Eur J Cardiothorac Surg 17 492–494 Occurrence Handle10773577 Occurrence Handle10.1016/S1010-7940(00)00366-3 Occurrence Handle1:STN:280:DC%2BD3c3jslamsg%3D%3D
CA Velez J Kahn (2000) ArticleTitleCompartment syndrome from balloon pump Cathet Cardiovasc Intervent 51 217–219 Occurrence Handle10.1002/1522-726X(200010)51:2<217::AID-CCD19>3.0.CO;2-S Occurrence Handle1:STN:280:DC%2BD3M%2Fis1Kguw%3D%3D
A Benicio LF Moreira JO Auler (1999) ArticleTitleParaplegia following intraaortic balloon circulatory assistance Arg Bras Cardiol 72 487–492 Occurrence Handle1:STN:280:DC%2BD3c%2FgtVKrug%3D%3D
T Busch H Sirbu D Zenker et al. (1997) ArticleTitleVascular complications related to intra-aortic balloon counterpulsation; an analysis of 10 years' experience Thorac Cardiovasc Surg 45 55–59 Occurrence Handle9175219 Occurrence Handle1:STN:280:ByiA3Mfis1I%3D Occurrence Handle10.1055/s-2007-1013687
J Mand'ák V Lonský J Dominik et al. (2005) ArticleTitleVascular complications of intra-aortic balloon counterpulsation Angiology 56 69–74 Occurrence Handle15678258 Occurrence Handle10.1177/000331970505600109
KH Scholz S Ragab F von zur Muhlen et al. (1998) ArticleTitleComplications of intra-aortic balloon counterpulsation. The role of catheter size and duration of support in multivariate analysis of risk Eur Heart J 19 458–465 Occurrence Handle9568450 Occurrence Handle10.1053/euhj.1997.0802 Occurrence Handle1:STN:280:DyaK1c3ivFyksA%3D%3D
S Kuki K Taniguchi T Masai et al. (2001) ArticleTitleUsefulness of the low-profile “true 8” intra-aortic balloon pumping catheter for preventing limb ischemia ASAIO J 47 611–614 Occurrence Handle11730197 Occurrence Handle10.1097/00002480-200111000-00008 Occurrence Handle1:STN:280:DC%2BD3MnotlOhtQ%3D%3D
H Eltchaninoff AP Dirnas PL Whitlow (1993) ArticleTitleComplications associated with percutaneous placement and use of intra-aortic balloon counterpulsation Am J Cardiol 71 328–332 Occurrence Handle8427177 Occurrence Handle10.1016/0002-9149(93)90800-R Occurrence Handle1:STN:280:ByyC2M7hsFw%3D
T Igari F Iwaya K Hagiwara et al. (1993) ArticleTitleThe optimal sizing of prosthetic graft for the infrarenal abdominal aorta Jpn J Artif Organs 22 1116–1120
TG Papaioannou C Stefanadis (2005) ArticleTitleBasic principles of the intraaortic balloon pump and mechanisms affecting its performance ASAIO J 51 296–300 Occurrence Handle15968962 Occurrence Handle10.1097/01.MAT.0000159381.97773.9B
N Tutui Y Tutui K Kanda (1996) ArticleTitleBalloon catheter of IABP. Development of suitable size for Japanese Heart Nurs 9 568–573
N Soeda T Murakami S Sato et al. (1997) ArticleTitleDiameter and length of descending aorta Junkankika 41 331–332
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Igari, T. The length of the aorta from the subclavian artery to the renal artery based on computed tomographic measurements in Japanese adults. J Artif Organs 9, 267–270 (2006). https://doi.org/10.1007/s10047-006-0346-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10047-006-0346-z