Abstract
Diffuse optical imaging has been applied to measure the localized hemodynamic responses to brain activation. One of the serious problems with diffuse optical imaging is the limitation of the spatial resolution caused by the sparse probe arrangement and broadened spatial sensitivity profile for each probe pair. High-density probe arrangements and an image reconstruction algorithm considering the broadening of the spatial sensitivity can improve the spatial resolution of the image. In this study, the diffuse optical imaging of the absorption change in the brain is simulated to evaluate the effect of the high-density probe arrangements and imaging methods. The localization error, equivalent full-width half maximum and circularity of the absorption change in the image obtained by the mapping and reconstruction methods from the data measured by five probe arrangements are compared to quantitatively evaluate the imaging methods and probe arrangements. The simple mapping method is sufficient for the density of the measurement points up to the double-density probe arrangement. The image reconstruction method considering the broadening of the spatial sensitivity of the probe pairs can effectively improve the spatial resolution of the image obtained from the probe arrangements higher than the quadruple density, in which the distance between the neighboring measurement points is 10.6 mm.
Similar content being viewed by others
References
Koizumi, H., Yamamoto, T., Maki, A., Yamashita, Y., Sato, H., Kawaguchi, H., Ichikawa, N.: Optical topography: practical problems and new applications. Appl. Opt. 42, 3054 (2003)
Yamamoto, T., Maki, A., Kadoya, T., Tanikawa, Y., Yamada, Y., Okada, E., Koizumi, H.: Arranging optical fibres for the spatial resolution improvement of topographic images. Phys. Med. Biol. 47, 3429 (2002)
Kawaguchi, H., Koyama, T., Okada, E.: Effect of probe arrangement on reproducibility of images by near-infrared topography evaluated by a virtual head phantom. Appl. Opt. 46, 1658 (2007)
Arridge, S.R., Hebden, J.C.: Optical imaging in medicine: II. Modelling and reconstruction. Phys. Med. Biol. 42, 841 (1997)
Boas, D.A., Gaudette, T., Strangman, G., Cheng, X., Marota, J.J.A., Mandeville, J.B.: The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics. NeuroImage 13, 76 (2001)
White, B.R., Culver, J.P.: Quantitative evaluation of high-density diffuse optical tomography: in vivo resolution and mapping performance. J. Biomed. Opt. 15, 026006 (2010)
Eggebrecht, A.T., White, B.R., Ferradal, S.L., Chen, C., Zhan, Y., Snyder, A.Z., Dehghani, H., Culver, J.P.: A quantitative spatial comparison of high-density diffuse optical tomography and fMRI cortical mapping. NeuroImage. 61, 1120 (2012)
Habermehl, C., Holtze, S., Steinbrink, J., Koch, S.P., Obrig, H., Mehnert, J., Schmitz, C.H.: Somatosensory activation of two fingers can be discriminated with ultrahigh-density diffuse optical tomography. NeuroImage. 59, 3201 (2012)
Tian, F., Alexandrakis, G., Liu, H.: Optimization of probe geometry for diffuse optical brain imaging based on measurement density and distribution. Appl. Opt. 48, 2496 (2009)
Simpson, C.R., Kohl, M., Essenpreis, M., Cope, M.: Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. Phys. Med. Biol. 43, 2465 (1998)
Firbank, M., Hiraoka, M., Essenpreis, M., Delpy, D.T.: Measurement of the optical properties of the skull in the wavelength range 650-950 nm. Phys. Med. Biol. 38, 503 (1993)
Okada, E., Delpy, D.T.: Near-infrared light propagation in an adult head model. I. Modeling of low-level scattering in the cerebrospinal fluid layer. Appl. Opt. 42, 2906 (2003)
van der Zee, P., Essenpreis, M., Delpy, D.T.: Optical properties of brain tissue. Proc. SPIE. 1888, 454 (1993)
Okada, E., Delpy, D.T.: Near-infrared light propagation in an adult head model. II. Effect of superficial tissue thickness on the sensitivity of the near-infrared spectroscopy signal. Appl. Opt. 42, 2915 (2003)
Okada, E.: The effect of superficial tissue of the head on spatial sensitivity profiles for near infrared spectroscopy and imaging. Opt. Rev. 7, 375 (2000)
Zhan, Y., Eggebrecht, A.T., Culver, J.P., Dehghni, H.: Image quality analysis of high-density diffuse optical tomography incorporating a subject-specific head model. Front Neuroenergetics. 4, 6 (2012)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sakakibara, Y., Kurihara, K. & Okada, E. Evaluation of improvement of diffuse optical imaging of brain function by high-density probe arrangements and imaging algorithms. Opt Rev 23, 346–353 (2016). https://doi.org/10.1007/s10043-015-0176-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10043-015-0176-4