This paper describes a new near infrared (NIR) spectroscopic imager that has an expanded detection dynamic range intended for measurements with various transmitter-receiver (T-R) distances. Simultaneous multi-distance measurements for 48 points of the human forehead were performed to record brain activation by a mental test called digit span. Similarity Index (SI) analysis of 48 time-course curves was introduced for the evaluation of the result. A new mapping method toward depth direction is also shown for total hemoglobin and SI values. Simultaneous multi-distance measurements are useful for the brain functional analysis to distinguish depth variation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. F. F. Jobsis: Science 198 (1977) 1264.

    PubMed  Google Scholar 

  2. Y. Hoshi and M. Tamura: Neurosci. Lett. 150 (1993) 5.

    Article  PubMed  Google Scholar 

  3. T. Kato, A. Kamei, S. Takashima and T. Ozaki: J. Cereb. Blood Flow Metab. 13 (1993) 516.

    PubMed  Google Scholar 

  4. A. Maki, Y. Yamashita, Y. Ito, E. Watanabe, Y, Mayanagi and H. Koizumi: Med. Phys. 22 (1995) 1997.

    Article  PubMed  Google Scholar 

  5. I. Oda, Y. Wada, S. Takeuchi, Y. Oikawa, N. Sakauchi, Y. Ito, I. Konishi, Y. Tsunazawa, T. Kusaka, K. Isobe, S. Itoh and S. Onishi: Proc. SPIE 4250 (2001) 371.

  6. I. Konishi, S. Takeuchi, Y. Oikawa, Y. Wada, N. Sakauchi, Y. Ito, I. Oda and Y. Tunazawa: Shimadzu Rev. 57 (2000) 141.

    Google Scholar 

  7. I. Miyai, H. Yagura, I. Oda, I. Konishi, H. Eda, T. Suzuki and K. Kubota: Ann. Neurol. 52 (2002) 188.

    Article  PubMed  Google Scholar 

  8. K. Isobe, T. Kusaka, K. Nagano, K. Okubo, S. Yasuda, M. Kondo, S. Itoh and S. Onishi: Neurosci. Lett. 23 (2001) 221.

    Article  Google Scholar 

  9. S. Kohri, Y. Hoshi, M. Tamura, C. Kato, Y. Kuge and N. Tamaki: Physiol. Meas. 23 (2002) 301.

    Article  PubMed  Google Scholar 

  10. E. Ohmae, Y. Ouchi, M. Oda, T. Suzuki, S. Nobesawa, T. Kannno, E. Yoshikawa, M. Futatsubashi, H. Okada and Y. Yamashita: Proc. Asian Symposium Biomedical Optics and Photomedicine (Biomed. Opt. Group in Opt. Soc. Jpn., Sapporo, 2002) p. 190.

  11. T. J. Farrell, M. S. Patterson and B. Wilson: Med. Phys. 19 (1992) 879.

    Article  PubMed  Google Scholar 

  12. Y. Hoshi, I. Oda, Y. Wada, Y. Ito, Y. Yamashita, M. Oda, K. Ohta, Y. Yamada and M. Tamura: Cognitive Brain Research 9 (2000) 339.

    Article  PubMed  Google Scholar 

  13. A. Baddeley: Science 255 (1992) 556.

    PubMed  Google Scholar 

  14. S. J. Matcher, C. E. Elwell, C. E. Cooper, M. Cope and D. T. Delpy: Anal. Biochem. 227 (1995) 54.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Ichiro Oda or Ikuo Konishi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Oda, I., Wada, Y., Takeuchi, S. et al. Near Infrared Imager with a Flexible Source-Detector Arrangement and a New Detection Gain Control. OPT REV 10, 422–426 (2003). https://doi.org/10.1007/s10043-003-0422-z

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10043-003-0422-z

Key words

Navigation