We report a rare complication after laparoscopic fundoplication using a dual-sided PTFE/ePTFE (Bard® Crurasoft™) mesh fixation. A 53-year-old man was re-operated for a recurrent hiatal hernia. The hiatal hernia was reinforced using a mesh. Two years later, the patient presented with serious dysphagia and weight loss. An endoscopy revealed a migrated mesh in the stomach. The mesh was excreted within the stool without notice. The PTFE/ePTFE mesh, which is designed for treating hiatal defects, is considered to have superior tissue incorporation, together with less adhesion formation and fistulation. As mesh migration into the upper gastrointestinal tract is possible, it should be used with great care in the peri-oesophageal region.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Hunter JG, Smith CD, Branum GD, Waring JP, Trus TL, Cornwell M, Galloway K (1999) Laparoscopic fundoplication failures: patterns of failure and response to fundoplication revision. Ann Surg 230:595–604; discussion 604–6

    Article  PubMed  CAS  Google Scholar 

  2. Soper NJ, Dunnegan D (1999) Anatomic fundoplication failure after laparoscopic antireflux surgery. Ann Surg 229:669–676; discussion 676–7

    Article  PubMed  CAS  Google Scholar 

  3. Oelschlager BK, Barreca M, Chang L, Pellegrini CA (2003) The use of small intestine submucosa in the repair of paraesophageal hernias: initial observations of a new technique. Am J Surg 186:4–8

    Article  PubMed  Google Scholar 

  4. Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R (2005) Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg 140:40–48. doi:10.1001/archsurg.140.1.40

    Article  PubMed  Google Scholar 

  5. Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137:649–652

    Article  PubMed  Google Scholar 

  6. Spechler SJ, Lee E, Ahnen D, Goyal RK, Hirano I, Ramirez F, Raufman JP, Sampliner R, Schnell T, Sontag S, Vlahcevic ZR, Young R, Williford W (2001) Long-term outcome of medical and surgical therapies for gastroesophageal reflux disease: follow-up of a randomized controlled trial. JAMA 285:2331–2338

    Article  PubMed  CAS  Google Scholar 

  7. Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJ Jr, Michael Brunt L, Hunter JG, Demeester TR, Swanstrom LL, Daniel Smith C, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226. doi:10.1007/s00464-008-0205-5

    Article  PubMed  Google Scholar 

  8. Carlson MA, Condon RE, Ludwig KA, Schulte WJ (1998) Management of intrathoracic stomach with polypropylene mesh prosthesis reinforced transabdominal hiatus hernia repair. J Am Coll Surg 187:227–230

    Article  PubMed  CAS  Google Scholar 

  9. Gajbhiye R, Quraishi AH, Mahajan P, Warhadpande M (2005) Dysphagia due to transmural migration of polypropylene mesh into esophagus. Indian J Gastroenterol 24:226–227

    PubMed  Google Scholar 

  10. Dutta S (2007) Prosthetic esophageal erosion after mesh hiatoplasty in a child, removed by transabdominal endogastric surgery. J Pediatr Surg 42:252–256. doi:10.1016/j.jpedsurg.2006.09.043

    Article  PubMed  Google Scholar 

  11. Zilberstein B, Eshkenazy R, Pajecki D, Granja C, Brito AC (2005) Laparoscopic mesh repair antireflux surgery for treatment of large hiatal hernia. Dis Esophagus 18:166–169. doi:10.1111/j.1442-2050.2005.00494.x

    Article  PubMed  CAS  Google Scholar 

  12. Coluccio G, Ponzio S, Ambu V, Tramontano R, Cuomo G (2000) Dislocation into the cardial lumen of a PTFE prosthesis used in the treatment of voluminous hiatal sliding hernia, A case report. Minerva Chir 55:341–345

    PubMed  CAS  Google Scholar 

  13. Hergueta-Delgado P, Marin-Moreno M, Morales-Conde S, Reina-Serrano S, Jurado-Castillo C, Pellicer-Bautista F, Herrerias-Gutierrez JM (2006) Transmural migration of a prosthetic mesh after surgery of a paraesophageal hiatal hernia. Gastrointest Endosc 64:120. doi:10.1016/j.gie.2006.01.034

    Article  PubMed  Google Scholar 

  14. Griffith PS, Valenti V, Qurashi K, Martinez-Isla A (2008) Rejection of goretex mesh used in prosthetic cruroplasty: a case series. Int J Surg 6:106–109. doi:10.1016/j.ijsu.2007.12.004

    Article  PubMed  Google Scholar 

  15. Schauer PR, Ikramuddin S, McLaughlin RH, Graham TO, Slivka A, Lee KK, Schraut WH, Luketich JD (1998) Comparison of laparoscopic versus open repair of paraesophageal hernia. Am J Surg 176:659–665

    Article  PubMed  CAS  Google Scholar 

  16. Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J, Swanstrom L (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490. doi:10.1097/01.sla.0000237759.42831.03

    PubMed  Google Scholar 

  17. Lee E, Frisella MM, Matthews BD, Brunt LM (2007) Evaluation of acellular human dermis reinforcement of the crural closure in patients with difficult hiatal hernias. Surg Endosc 21:641–645. doi:10.1007/s00464-006-9117-4

    Article  PubMed  CAS  Google Scholar 

  18. Jacobs M, Gomez E, Plasencia G, Lopez-Penalver C, Lujan H, Velarde D, Jessee T (2007) Use of surgisis mesh in laparoscopic repair of hiatal hernias. Surg Laparosc Endosc Percutan Tech 17:365–368. doi:10.1097/SLE.0b013e318123fc49

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Carpelan-Holmström.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Carpelan-Holmström, M., Kruuna, O., Salo, J. et al. Late mesh migration through the stomach wall after laparoscopic refundoplication using a dual-sided PTFE/ePTFE mesh. Hernia 15, 217–220 (2011). https://doi.org/10.1007/s10029-010-0633-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10029-010-0633-8

Keywords

Navigation