Abstract
We report a rare complication after laparoscopic fundoplication using a dual-sided PTFE/ePTFE (Bard® Crurasoft™) mesh fixation. A 53-year-old man was re-operated for a recurrent hiatal hernia. The hiatal hernia was reinforced using a mesh. Two years later, the patient presented with serious dysphagia and weight loss. An endoscopy revealed a migrated mesh in the stomach. The mesh was excreted within the stool without notice. The PTFE/ePTFE mesh, which is designed for treating hiatal defects, is considered to have superior tissue incorporation, together with less adhesion formation and fistulation. As mesh migration into the upper gastrointestinal tract is possible, it should be used with great care in the peri-oesophageal region.
References
Hunter JG, Smith CD, Branum GD, Waring JP, Trus TL, Cornwell M, Galloway K (1999) Laparoscopic fundoplication failures: patterns of failure and response to fundoplication revision. Ann Surg 230:595–604; discussion 604–6
Soper NJ, Dunnegan D (1999) Anatomic fundoplication failure after laparoscopic antireflux surgery. Ann Surg 229:669–676; discussion 676–7
Oelschlager BK, Barreca M, Chang L, Pellegrini CA (2003) The use of small intestine submucosa in the repair of paraesophageal hernias: initial observations of a new technique. Am J Surg 186:4–8
Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R (2005) Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg 140:40–48. doi:10.1001/archsurg.140.1.40
Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137:649–652
Spechler SJ, Lee E, Ahnen D, Goyal RK, Hirano I, Ramirez F, Raufman JP, Sampliner R, Schnell T, Sontag S, Vlahcevic ZR, Young R, Williford W (2001) Long-term outcome of medical and surgical therapies for gastroesophageal reflux disease: follow-up of a randomized controlled trial. JAMA 285:2331–2338
Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJ Jr, Michael Brunt L, Hunter JG, Demeester TR, Swanstrom LL, Daniel Smith C, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226. doi:10.1007/s00464-008-0205-5
Carlson MA, Condon RE, Ludwig KA, Schulte WJ (1998) Management of intrathoracic stomach with polypropylene mesh prosthesis reinforced transabdominal hiatus hernia repair. J Am Coll Surg 187:227–230
Gajbhiye R, Quraishi AH, Mahajan P, Warhadpande M (2005) Dysphagia due to transmural migration of polypropylene mesh into esophagus. Indian J Gastroenterol 24:226–227
Dutta S (2007) Prosthetic esophageal erosion after mesh hiatoplasty in a child, removed by transabdominal endogastric surgery. J Pediatr Surg 42:252–256. doi:10.1016/j.jpedsurg.2006.09.043
Zilberstein B, Eshkenazy R, Pajecki D, Granja C, Brito AC (2005) Laparoscopic mesh repair antireflux surgery for treatment of large hiatal hernia. Dis Esophagus 18:166–169. doi:10.1111/j.1442-2050.2005.00494.x
Coluccio G, Ponzio S, Ambu V, Tramontano R, Cuomo G (2000) Dislocation into the cardial lumen of a PTFE prosthesis used in the treatment of voluminous hiatal sliding hernia, A case report. Minerva Chir 55:341–345
Hergueta-Delgado P, Marin-Moreno M, Morales-Conde S, Reina-Serrano S, Jurado-Castillo C, Pellicer-Bautista F, Herrerias-Gutierrez JM (2006) Transmural migration of a prosthetic mesh after surgery of a paraesophageal hiatal hernia. Gastrointest Endosc 64:120. doi:10.1016/j.gie.2006.01.034
Griffith PS, Valenti V, Qurashi K, Martinez-Isla A (2008) Rejection of goretex mesh used in prosthetic cruroplasty: a case series. Int J Surg 6:106–109. doi:10.1016/j.ijsu.2007.12.004
Schauer PR, Ikramuddin S, McLaughlin RH, Graham TO, Slivka A, Lee KK, Schraut WH, Luketich JD (1998) Comparison of laparoscopic versus open repair of paraesophageal hernia. Am J Surg 176:659–665
Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J, Swanstrom L (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490. doi:10.1097/01.sla.0000237759.42831.03
Lee E, Frisella MM, Matthews BD, Brunt LM (2007) Evaluation of acellular human dermis reinforcement of the crural closure in patients with difficult hiatal hernias. Surg Endosc 21:641–645. doi:10.1007/s00464-006-9117-4
Jacobs M, Gomez E, Plasencia G, Lopez-Penalver C, Lujan H, Velarde D, Jessee T (2007) Use of surgisis mesh in laparoscopic repair of hiatal hernias. Surg Laparosc Endosc Percutan Tech 17:365–368. doi:10.1097/SLE.0b013e318123fc49