Skip to main content
Log in

Combined fascia and mesh repair of incisional hernias

  • Original Article
  • Published:
Hernia Aims and scope Submit manuscript

Abstract

Incisional hernia is a relatively common complication following abdominal operations. Due to high recurrence rates following primary suture, a prosthetic mesh is now usually used to repair the hernia. Several different types of repair are described. A combined fascia and mesh technique avoids opening the peritoneal cavity and potential damage to bowel. This study describes results of this technique. Consecutive patients undergoing the operation were contacted to assess freedom from recurrence and satisfaction with results. Some 34 patients underwent 36 incisional repairs. Of the 34 patients 21 were men and 13 were women with a median age of 69 years (range 31–86 years). The causative incisions were midline (30), Kochers (2), Pfannesteil (2) and transverse (2). The median time spent in hospital was three nights (range 1–14 days). Two patients developed seromas, another complained of pain soon after operation, one patient developed a superficial wound infection another developed a tender drain site which required exploration. One patient with significant co-morbidity died 13 days postoperatively from multiorgan failure. Freedom from recurrence of the hernia was 91% at 5 years. However patient survival was only 70% at 5 years. This technique is associated with low postoperative morbidity and a low recurrence rate. Patients presenting with incisional hernias have a poor long-term prognosis which needs to be borne in mind when planning intervention.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Mudge M, Hughes LE (1985) Incisional hernia: a ten year prospective study of incidence and attitudes. Br J Surg 72:70

    Article  PubMed  CAS  Google Scholar 

  2. Stevick CA, Long JB, Jamasbi, Nash M (1988) Ventral hernia following abdominal aortic reconstruction. Am J Surg 54:287–289

    CAS  Google Scholar 

  3. Rogers M, McCarthy R, Earnshaw JJ (2003) Prevention of incisional hernia after aortic aneurysm repair. Eur J Vasc Surg 26:519–522

    Article  CAS  Google Scholar 

  4. Langer S, Christiansen J (1985) Long-term results after incisional hernia repair. Acta Chir Scand 151:217–219

    PubMed  CAS  Google Scholar 

  5. Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, Ozermans JN, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC, Bruijninckx CM, Jeekel J (2000) A comparison of suture repair with mesh repair for incisional hernia. New Engl J Med 343:392–398

    Article  PubMed  CAS  Google Scholar 

  6. Liakos T, Karanikas I, Panagiotidis M, Dendringos S (1994) Use of marlex mesh in the repair of recurrent incisional hernia. Br J Surg 81:248–249

    Article  PubMed  Google Scholar 

  7. Whiteley MS, Ray-Chaudhuri SB, Galland RB (1998) Combined fascia and mesh closure of large incisional hernias. J R Coll Surg Edinb 43:29–30

    PubMed  CAS  Google Scholar 

  8. Kingsnorth, Sivarajasingham N, Wong S, Butler M (2004) Open mesh repair of incisional hernias with significant loss of domain. Ann R Surg Engl 84:363–366

    Article  Google Scholar 

  9. Munro A, Cassar K (2004) Repair of incisional hernia. In: Johnson C, Taylor I (eds) Recent advances in surgery, vol 27. Royal Society of Medicine, London, pp 41–53

  10. Basoglu M, Yildirgan MI, Yilmaz I, Balik A, Celebi F, Atamanalp SS, Polat KY, Oren D (2004) Late complications of incisional hernias following prosthetic mesh repair. Acta Chir Belg 104:425–428

    PubMed  CAS  Google Scholar 

  11. Heniford BT, Park AP, Ramshaw BJ, Voeller G (2003) Laparoscopic repair of ventral hernias: nine years’ experience with 850 consecutive hernias. Ann Surg 238:391–400

    PubMed  Google Scholar 

  12. Molloy RG, Moran KT, Waldron RP, Brady MP, Kirwan WO (1991) Massive incisional hernia: abdominal wall replacement with Marlex mesh. Br J Surg 78:242–244

    Article  PubMed  CAS  Google Scholar 

  13. Matapurkar BG, Gupta AK, Agarwal AK (1991) A new technique of “marlex-peritoneal sandwich” in the repair of large incisional hernias. World J Surg 15 768–770

    Article  PubMed  CAS  Google Scholar 

  14. Chevrel JP, Rath AM (1997) The use of fibrin glues in the surgical treatment of incisional hernias. Hernia 1:9–14

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. B. Galland.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lawson-Smith, M.J., Galland, R.B. Combined fascia and mesh repair of incisional hernias. Hernia 10, 262–265 (2006). https://doi.org/10.1007/s10029-006-0082-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10029-006-0082-6

Keywords

Navigation