Albumin-impregnated prosthetic graft for infrarenal aortic replacement: Effects on the incidence and volume of perioperative blood transfusion

  • Original Article
  • Published:
Annals of Vascular Surgery

Abstract

We retrospectively reviewed 290 cases in which an albumin-impregnated polyester prosthetic graft was used for surgical management of aortic bifurcation disease between November 1987 and December 1990. The purpose of this review was to determine the incidence and volume of blood transfusion and to evaluate the rate of patency and the incidence of infection achieved using this type of prosthesis. The indication for surgery was abdominal aortic aneurysm (AAA) in 218 cases (190 elective procedures and 28 emergency procedures) and occlusive disease of the aortic bifurcation (ODAB) in 72 cases. Mean follow-up was 25.5 ± 13.4 months (range: 1 and 50 months). The incidence of blood transfusion for elective AAA and ODAB surgery was 30.2% and 32.3% intraoperatively, 21.3% and 12.9% postoperatively, and 40.4% and 42.6% overall. The mean number of red cell packs transfused for elective AAA and ODAB surgery was respectively 1 and 0.8 intraoperatively, 0.4 and 0.6 postoperatively, and 1.4 and 1 overall. No immediate or late graft infection prosthesis was observed in any patient in this series. Primary and secondary patency was 95.5% and 97.5% at 6 months with no graft thrombosis during further follow-up. The fact that use of an impregnated graft in management of aortic bifurcation disease was accompanied by a high incidence and volume of blood transfusion suggests that these grafts do not reduce perioperative blood loss. Use of an impregnated prosthesis had no effect on the rate of patency and the incidence infection. (Ann Vasc Surg 1997; 11:588-595.)

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Chakfe N, Chaput C, Douville Y, et al. Woven velour polyester arterial grafts with polypropylene wrap: In vivo evaluation. In Szycher M, ed. High Performance Biomaterials: A Comprehensive Guide to Medical/Pharmaceutical Applications. Technomic Publishing Co., 1991, pp 405–424.

  2. Guidoin R, King M, et al. New polyester arterial prostheses from Great Britain: An in vitro and in vivo evaluation. Ann Biomed Eng 1986;14:351–367.

    Article  PubMed  CAS  Google Scholar 

  3. Yates SG, D’Sa Barros AAB, Berger K, et al. The preclotting of porous arterial prostheses. Ann Surg 1978;188:611–622.

    Article  PubMed  CAS  Google Scholar 

  4. Humphries AW, Hawk WA, Cuthberson AM. Arterial prosthesis of collagen-impregnated Dacron tulle. Surgery 1961; 50:947–954.

    PubMed  CAS  Google Scholar 

  5. Bascom JU. Gelatin to prevent blood loss from knitted arterial grafts. Surgery 1961;50:504–512.

    PubMed  CAS  Google Scholar 

  6. Jordan GL, Stump MM, Allen J, et al. Gelatin-impregnated Dacron prosthesis implanted into porcine thoracic aorta. Surgery 1963;53:45–49.

    Google Scholar 

  7. Wesolowski SA, Fries CC, Domingo RT, et al. The compound prosthetic vascular graft: a pathologic survey. Surgery 1963; 53:19–44.

    PubMed  CAS  Google Scholar 

  8. Domurado D, Thomas D, Broun G. A new method for producing proteic coatings. J Biomed Mat Res 1975;9:109–110.

    Article  CAS  Google Scholar 

  9. Ad Hoc Committee on Reporting Standards. Suggested standards for reports dealing with lower extremity ischemia. J Vasc Surg 1986;4:80–94.

    Article  Google Scholar 

  10. Guidoin R, Marois Y, Rao TJ, et al. An albumin-coated polyester arterial prosthesis made ready to anastomose: In vivo evaluation in dogs. Clin Mat 1988;3:119–131.

    Article  Google Scholar 

  11. Drury JK, Ashton TR, Cunningham JD, et al. Experimental and clinical experience with a gelatin impregnated Dacron prosthesis. Ann Vasc Surg 1987;l:542–547.

    Article  Google Scholar 

  12. Chakfe N, Marois Y, Guidoin R, et al. Biocompatibility and biofunctionality of a gelatin impregnated polyester arterial prosthesis. Polym Polym Comp 1993;1:229–251.

    CAS  Google Scholar 

  13. Guidoin R, Marceau D, Couture et al. Collagen coatings as biological sealants for textile arterial prostheses. Biomaterials 1989;10:156–165.

    Article  PubMed  CAS  Google Scholar 

  14. Branchereau A, Rudondy P, Gournier JP, Espinoza JP. The albumin-coated knitted Dacron aortic prosthesis: A clinical study. Ann Vasc Surg 1990;4:138–142.

    Article  PubMed  CAS  Google Scholar 

  15. Reid DB, Pollock JG. A prospective study of 100 Gelatinsealed aortic grafts. Ann Vasc Surg 1991;5:320–324.

    Article  PubMed  CAS  Google Scholar 

  16. Balzer K, Werner HH, Adamek L, et al. Results after implantation of gelatin-impregnated bifurcated grafts. Thorac Cardiovasc Surg 1988;36:351–355.

    Article  PubMed  CAS  Google Scholar 

  17. Freischlag JA, Moore WS. Clinical experience with a collagen-impregnated knitted Dacron vascular graft. Ann Vasc Surg 1990;4:449–454.

    Article  PubMed  CAS  Google Scholar 

  18. Grabitz K, Sandmann W. Clinical experience with Microvel® Hemashield® prostheses. Angio Archiv 1985;9:52–54.

    Google Scholar 

  19. Lorentzen JE, Nielsen OM, Buchardt-Hansen HJ. Clinical experience with collagen-impregnated velour prosthesis: A prospective study of 50 consecutive graft implantations. Angio Archiv 1985;9:59–61.

    Google Scholar 

  20. Norgren L, Berggren U, Parsson H, et al. How does Hemashield® affect surgical technique? Clinical results in aortic reconstructions. Angio Archiv 1985;9:39–43.

    Google Scholar 

  21. Raithel D, Noppeney TH, Schweiger H, et al. Early experience with the Meadox collagen prosthesis for aorto-femoral reconstruction. Angio Archiv 1985;9:49–51.

    Google Scholar 

  22. Reigel MM, Hollier LH, Pairolero PC, Hallett JW. Early experience with a new collagen-impregnated aortic graft. Am Surg 1988;54:134–136.

    PubMed  CAS  Google Scholar 

  23. Stegmann TH, Haverich A, Borst HG. First clinical experiences with a new collagen-impregnated Dacron-double-velour prosthesis: Control of blood loss. Angio Archiv 1985; 9:22–38.

    Google Scholar 

  24. Guidoin R, Downs A, Verhaeghe JL, et al. Pre-operative bleeding at polyester (Dacron®) arterial prosthesis implantation. Int J Artif Organs 1987;10:393–398.

    PubMed  CAS  Google Scholar 

  25. Courroucé AM. Séropositivité VIH chez les donneurs de sang de 1990 à 1992: Prévalence, estimation du risque résiduel d’infections transfusionnelles et épidémiologie. Rev Fr Trans Hémobiol 1993;36:327–337.

    Article  Google Scholar 

  26. Weisel RD, Dennis RC, Manny J, et al. Adverse effects of transfusion therapy during abdominal aortic aneurysectomy. Surgery 1978;83:682–690.

    PubMed  CAS  Google Scholar 

  27. Diehl JC, Cali RF, Hertzer NR, Beven EG. Complications of abdominal aortic reconstruction: An analysis of perioperative risk factors in 557 patients. Ann Surg 1983;197:49–56.

    PubMed  CAS  Google Scholar 

  28. Lord RSA, Nash PA, Raj BT, et al. Prospective randomized trail of polytetrafluoroethylène and Dacron aortic prosthesis. I. Perioperative results. Ann Vasc Surg 1988;2:248–254.

    Article  PubMed  CAS  Google Scholar 

  29. Fischer JB, Dennis RC, Valeri CR, et al. Effect of graft material on loss of erythrocytes after aortic operations. Surg Gynecol Obstet 1991;173:131–136.

    Google Scholar 

  30. Olah A, Pasic M, Redaelli C, et al. Blood substitution in aorto-iliac surgery. Helv Chir Acta 1992;58:801–804.

    PubMed  CAS  Google Scholar 

  31. Pillgram-Larsen J, Florenes T, Zasada W, Semb G. Peroperative autotransfusion in aortic surgery. Tidsskr Nor Laegeforen 1989;109:1885–1886.

    PubMed  CAS  Google Scholar 

  32. Hallett JW, Popovsky M, Ilstrup D. Minimizing blood transfusions during abdominal aortic surgery: Recent advances in rapid autotransfusion. J Vasc Surg 1987;5:601–606.

    Article  PubMed  Google Scholar 

  33. Harris PL. Comparison between a new collagen-impregnated graft (Microvel® Hemashield®) and a standard velour knitted graft (Microvel®) in the management of aortic bifurcation disease. Angio Archiv 1985;9:67–72.

    Google Scholar 

  34. De Mol Van Otterloo JCA, Van Bockel JH, Ponfoort ED, et al. Randomized study on the effect of collagen impregnation of knitted Dacron® velour aortoiliac prostheses on blood loss during aortic reconstruction. Br J Surg 1991;78:288–292.

    Article  PubMed  Google Scholar 

  35. Lethagen S, Rugarn P, Bergqvist D. Blood loss and safety with desmopressin or placebo during aorto-iliac graft surgery. Eur J Vasc Surg 1991;5:173–178.

    Article  PubMed  CAS  Google Scholar 

  36. Lord RA, Roath OS, Thompson JF, et al. Effect of aprotinin on neutrophil function after major vascular surgery. Br J Surg 1992;79:517–521.

    Article  PubMed  CAS  Google Scholar 

  37. Ouriel K, Shortell CK, Green RM, DeWeese JA. Intraoperative autotransfusion in aortic surgery. J Vasc Surg 1993; 18:16–22.

    Article  PubMed  CAS  Google Scholar 

  38. McKenzie FN, Heimbecker RO, Wall W, et al. Intraoperative autotransfusion in elective and emergency vascular surgery. Surgery 1978;83:470–475.

    PubMed  CAS  Google Scholar 

  39. Claeys L, Horsch S. Autotransfusion of nonwashed shed blood during vascular surgery. J Cardiovasc Surg 1992;33:89.

    Google Scholar 

  40. Sieunarine K, Lawrence-Brown MMD, Brenman D, et al. The quality of blood used for transfusions. J Cardiovasc Surg 1992;33:98–105.

    CAS  Google Scholar 

  41. Reddy DJ, Ryan CJ, Shepard AD, et al. Intraoperative autotransfusion in vascular surgery. Arch Surg 1990;125:1012–1016.

    PubMed  CAS  Google Scholar 

  42. Stanton PE, Shannon J, Rosenthal D, et al. Intraoperative autologous transfusion during major aortic reconstructive procedures. South Med J 1987;80:315–319.

    PubMed  Google Scholar 

  43. Cutler BS. Avoidance of homologous transfusion in aortic operations: The role of autotransfusion, hemodilution, and surgical technique. Surgery 1984;95:717–723.

    PubMed  CAS  Google Scholar 

  44. Kelley-Patteson C, Ammar AD, Kelley H. Should the Cell Saver autotransfusion device be used routinely in all infrarenal abdominal aortic bypass operations? J Vasc Surg 1993; 18:261–265.

    Article  PubMed  CAS  Google Scholar 

  45. Davidson J, Beucart D, Edwards WH, Muhlerin JL. The role of graft material in aortic reconstructive surgery. Ann Surg 1983;197:714–720.

    Article  PubMed  CAS  Google Scholar 

  46. Petrovic P, Lotina S, Djordjevic M, et al. Results of 132 PTFE (Gore-Tex) bifurcated graft implantation. J Cardiovasc Surg 1989;30:987–901.

    Google Scholar 

  47. Wooster DL, Louch RE, Krajden S. Intra-operative bacterial contamination of vascular grafts: A prospective study. Can J Surg 1985;28:407–409.

    PubMed  CAS  Google Scholar 

  48. Siverhus DJ, Schmitt DD, Edmiston CE, et al. Adherence of mucin and non-mucin-producing staphylococci to preclotted and albumin-coated velour knitted vascular grafts. Surgery 1990;104:613–619.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Chakfé, N., Beaufigeau, M., Epailly, P.N. et al. Albumin-impregnated prosthetic graft for infrarenal aortic replacement: Effects on the incidence and volume of perioperative blood transfusion. Annals of Vascular Surgery 11, 588–595 (1997). https://doi.org/10.1007/s100169900096

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s100169900096

Keywords

Navigation