Abstract
The advent of endovascular therapy has had a profound impact on repair of abdominal aortic aneurysms (AAA). Prudent patient selection, particularly in regard to unfavorable anatomy, is emerging as perhaps the most important determinant of endovascular abdominal aortic aneurysm repair (EVAR) outcome. The aim of this study was to examine the association of one such anatomic factor, proximal aortic neck angulation, with the incidence of adverse events following EVAR. Prospectively collected data on 289 EVAR repairs with the Talent endograft (Medtronic, Inc., Minneapolis, MN) from March 1998 to June 2000 were analyzed. Stent graft–specific adverse events studied were migration, endoleak, kinking, thrombosis, and AAA expansion. Computed tomography (CT) scanning with three-dimensional post-processing and/or aortography was used to measure aortic neck angle. Patients were categorized into one of four groups according to their neck angle: I (0-10°); II (11-39°); III (40-59°); or IV (60-85°). Outcomes were evaluated by chi-squared analysis and ANOVA. There was a direct correlation between AAA diameter and neck angle (p = 0.002). There was no difference in endoleak rate (p = 0.877), stent migration (p = 0.850), or AAA expansion rate (p = 0.599) between groups. Device kinking >45° was associated with neck angulation ≥60° (p = 0.013), but not with other adverse outcomes. The average neck angle was 30° in patients with endoleaks and 31° in patients without endoleaks. Increasing aortic neck angulation was not associated with the selected adverse outcomes within 1 year following EVAR with the Talent stent graft using suprarenal fixation with the exception of graft kinking. This may be related to the graft design that permits suprarenal aortic fixatiou of the proximal stent graft, Whether severe degrees of angulation of 60° or greater can be safely treated with suprarenal fixation requires further study.
Similar content being viewed by others
References
TA Chuter RM Green K Ouriel JA DeWeese (1994) ArticleTitleInfrarenal aortic aneurysm structure: implications for transfemoral repair J Vase Surg 20 44–49 Occurrence Handle1:STN:280:ByuA3c%2FmvF0%3D
JC Parodi JC Palmaz HD Barone (1991) ArticleTitleTransfemoral intraluminal graft implantation for abdominal aortic aneurysms Ann Vasc Surg 5 491–499 Occurrence Handle1:STN:280:By2C38nks1E%3D Occurrence Handle1837729
ED Dillavou SC Muluk RY Rhee et al. (2003) ArticleTitleDoes hostile neck anatomy preclude successful endovascular aortic aneurysm repair? J Vasc Surg 38 657–663 Occurrence Handle14560209
WC III Sternbergh G Carter JW York M Yoselevitz SR Money (2002) ArticleTitleAortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair J Vasc Surg 35 482–486 Occurrence Handle11877695
JP Carpenter RA Baum CF Barker et al. (2001) ArticleTitleImpact of exclusion criteria on patient selection for endovascular abdominal aortic aneurysm repair J Vasc Surg 34 1050–1054 Occurrence Handle1:STN:280:DC%2BD3MnpsFWmtw%3D%3D Occurrence Handle11743559
J Buth CJ Marrewijk Particlevan PL Harris WC Hop V Riambau RJ Laheij (2002) ArticleTitleOutcome of endovascular abdominal aortic aneurysm repair in patients with conditions considered unfit for an open procedure: a report on the EUROSTAR experience J Vasc Surg 35 211–221 Occurrence Handle11854717
PL Faries BJ Brener TL Connelly et al. (2002) ArticleTitleA multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms J Vasc Surg 35 1123–1128 Occurrence Handle12042722
FJ Criado RM Fainnan GJ Becker (2003) ArticleTitleTalent LPS AAA stent graft: results of a pivotal clinical trial J Vasc Surg 37 709–715 Occurrence Handle12663967
KW Johnston RB Rutherford MD Tilson DM Shah L Hollier JC Stanley (1991) ArticleTitleSuggested standards for reporting on arterial aneurysms. Subcommittee on Reporting Standards for Arterial Aneurysms, Ad Hoc Committee on Reporting Standards, Society for Vascular Surgery and North American Chapter, International Society for Cardiovascular Surgery J Vasc Surg 13 452–458 Occurrence Handle1:STN:280:By6C2MrhsFc%3D Occurrence Handle1999868
EL Chaikof ID Blankensteijn PL Harris et al. (2002) ArticleTitleReporting standards for endovascular aortic aneurysm repair J Vasc Surg 35 1048–1060 Occurrence Handle12021727
R Balm R Stokking R Kaatee ID Blankensteijn BC Eikelboom MS Leeuwen Particlevan (1997) ArticleTitleComputed tomographic angiographic imaging of abdominal aortic aneurysms: implications for transfemoral endovascular aneurysm management J Vasc Surg 26 231–237 Occurrence Handle1:STN:280:ByiH38risF0%3D Occurrence Handle9279309
J Albertini S Kalliafas S Travis et al. (2000) ArticleTitleAnatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms Eur J Vasc Endovasc Surg 19 308–312 Occurrence Handle1:STN:280:DC%2BD3c3hvFOitA%3D%3D Occurrence Handle10753697
CB Rockman PI Lamparello MA Adelman et al. (2002) ArticleTitleAneurysm morphology as a predictor of endoleak following endovascular aortic aneurysm repair: do smaller aneurysm have better outcomes? Ann Vasc Surg 16 644–651 Occurrence Handle12183772
BM Stanley JB Semmens Q Mai et al. (2001) ArticleTitleEvaluation of patient selection guidelines for endoluminal AAA repair with the Zenith stent-graft: the Australasian experience J Endovasc Ther 8 457–464 Occurrence Handle1:STN:280:DC%2BD3MnntF2htQ%3D%3D Occurrence Handle11718403
JN Albertini A Branchereau B Hopkinson et al. (2001) ArticleTitleMortality and morbidity following endovascular repair of abdominal aortic aneurysms: analysis of two single centre experiences Eur J Vasc Endovasc Surg 22 429–435 Occurrence Handle1:STN:280:DC%2BD3Mnpt12mug%3D%3D Occurrence Handle11735181
IV Mohan RJ Laheij PL Harris (2001) ArticleTitleRisk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repair Eur J Vasc Endovasc Surg 21 344–349 Occurrence Handle1:STN:280:DC%2BD3M3nsFyltw%3D%3D Occurrence Handle11359336
DM Hovsepian AN Hein TK Pilgram et al. (2001) ArticleTitleEndovascular abdominal aortic aneurysm repair in 144 patients: correlation of aneurysm size, proximal aortic neck length, and procedure-related complications J Vasc Interv Radiol 12 1373–1382 Occurrence Handle1:STN:280:DC%2BD3MjgtFWnsg%3D%3D Occurrence Handle11742009
DB Gitlitz G Ramaswami D Kaplan LH Hollier ML Marin (2001) ArticleTitleEndovascular stent grafting in the presence of aortic neck filling defects: early clinical experience J Vasc Surg 33 340–344 Occurrence Handle1:STN:280:DC%2BD3M7lslyrsA%3D%3D Occurrence Handle11174787
R Greenberg R Fairman S Srivastava F Criado R Green (2000) ArticleTitleEndovascular grafting in patients with short proximal necks: an analysis of short-term results Cardiovasc Surg 8 350–354 Occurrence Handle1:STN:280:DC%2BD3M%2FhvFOqug%3D%3D Occurrence Handle10959059
RK Greenberg D Clair S Srivastava et al. (2003) ArticleTitleShould patients with challenging anatomy be offered endovascular aneurysm repair? J Vasc Surg 38 990–996 Occurrence Handle14603205
NV Dias T Resch M Malina B Lindblad K Ivancev (2001) ArticleTitleIntraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stents J Endovasc Ther 8 268–273 Occurrence Handle1:STN:280:DC%2BD3MvksFKrsA%3D%3D Occurrence Handle11491261
MS Makaroun (2001) ArticleTitleThe Ancure endografting system: an update J Vasc Surg 33 S129–S134 Occurrence Handle1:STN:280:DC%2BD3M7lslynug%3D%3D Occurrence Handle11174824
HG Beebe JL Cronenwett BT Katzen DC Brewster RM Green (2001) ArticleTitleResults of an aortic endograft trial: impact of device failure beyond 12 months J Vasc Surg 33 S55–S63 Occurrence Handle1:STN:280:DC%2BD3M7lslymuw%3D%3D Occurrence Handle11174813
FR Arko W A Lee BB Hill P Cipriano TJ Fogarty CK Zarins (2001) ArticleTitleIncreased flexibility of AneuRx stent-graft reduces need for secondary intervention following endovascular aneurysm repair J Endovasc Ther 8 583–591 Occurrence Handle1:STN:280:DC%2BD38%2FntFGqsg%3D%3D Occurrence Handle11797973
JJ Wever AJ Nie Particlede JD Blankensteijn IA Broeders WP Mali BC Eikelboom (2000) ArticleTitleDilatation of the proximal neck of infra renal aortic aneurysms after endovascular AAA repair Eur J Vasc Endovasc Surg 19 197–201 Occurrence Handle1:STN:280:DC%2BD3c7psVSjtA%3D%3D Occurrence Handle10727371
DA Lipski CB Ernst (1998) ArticleTitleNatural history of the residual infrarenal aorta after infrarenal abdominal aortic aneurysm repair J Vasc Surg 27 805–811 Occurrence Handle1:STN:280:DyaK1c3otFCnsw%3D%3D Occurrence Handle9620131
B Sonesson T Resch T Lanne K Ivancev (1998) ArticleTitleThe fate of the infrarenal aortic neck after open aneurysm surgery J Vasc Surg 28 889–894 Occurrence Handle1:STN:280:DyaK1M%2FislOjtA%3D%3D Occurrence Handle9808858
RA Wain ML Marin T Ohki et al. (1998) ArticleTitleEndoleaks after endovascular graft treatment of aortic aneurysms: classification, risk factors, and outcome J Vasc Surg 27 69–78 Occurrence Handle1:STN:280:DyaK1c7jsVemuw%3D%3D Occurrence Handle9474084
PG Bove GW Long CJ Shanley et al. (2003) ArticleTitleTransrenal fixation of endovascular stent-grafts for infrarenal aortic aneurysm repair: mid-term results J Vasc Surg 37 938–942 Occurrence Handle12756336
ML Marin RE Parsons LH Hollier et al. (1998) ArticleTitleImpact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysms J Vasc Surg 28 638–646 Occurrence Handle1:STN:280:DyaK1M%2FgtVWqtQ%3D%3D Occurrence Handle9786258
AG Cowie RJ Ashleigh RE England CN McCollum (2003) ArticleTitleEndovascular aneurysm repair with the Talent stent-graft J Vasc Interv Radiol 14 1011–1016 Occurrence Handle12902558
LL Lau AG Hakaim WA Oldenburg et al. (2003) ArticleTitleEffect of suprarenal versus infrarenal aortic endograft fixation on renal function and renal artery patency: a comparative study with intermediate follow-up J Vasc Surg 37 1162–1168 Occurrence Handle12764259
Author information
Authors and Affiliations
Corresponding author
Additional information
Presented at the Twenty-ninth Annual Meeting of the Peripheral Vascular Surgery Society, Anaheim, CA, June 4-5, 2004.
About this article
Cite this article
Robbins, M., Kritpracha, B., Beebe, H.G. et al. Suprarenal Endograft Fixation Avoids Adverse Outcomes Associated with Aortic Neck Angulation. Ann Vasc Surg 19, 172–177 (2005). https://doi.org/10.1007/s10016-004-0161-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10016-004-0161-z