Abstract
Infrainguinal angioplasty has less initial and long-term success compared with more proximal sites. These suboptimal initial technical results may be related to the heavy calcific burden in the femoral and popliteal arteries and, subsequently, higher incidence of distal dissection. Cutting balloon angioplasty (CBA) is a newer technique that is thought to limit distal dissection in heavily calcified vessels; although CBA has been evaluated in the coronary circulation, there are few reports of its use in peripheral vessels. This study evaluates our initial experience with CBA for the management of femoropopliteal disease. Eleven patients underwent infrainguinal CBA for symptomatic limb ischemia at a community hospital. Ten procedures (91%) were technically successful, with no distal dissections, iatrogenic vessel perforations, or surgical target vessel revascularizations. In eight patients available for follow-up, the limb salvage rate was 100% and of seven and eight CBA sites (88%) were still widely patent (mean follow-up, 3 months; range, 2-12 months). This preliminary study suggests that CBA is safe and feasible for electively performed femoropopliteal chronic occlusive disease with acceptable success rates on short-term follow-up. Long-term results and comparison with other endovascular modalities require evaluation.
Similar content being viewed by others
References
B Stanley B Teague S Raptis DJ Taylor M Berce (1996) ArticleTitleEfficacy of balloon angioplasty of the superficial femoral artery and popliteal artery in the relief of leg ischemia J. Vasc. Surg. 23 679–685 Occurrence Handle1:STN:280:BymC1MbptVc%3D
PJ Matsi HI Manninen RL Vanninen et al. (1994) ArticleTitleFemoropopliteal angioplasty in patients with claudication: primary and secondary patency in 140 limbs with 1 to 3-year follow-up Radiology 191 727–733 Occurrence Handle1:STN:280:ByuB2c%2FivVA%3D Occurrence Handle8184053
R Adar GC Critchfield DM Eddy (1989) ArticleTitleA confidence profile analysis of the results of femoropopliteal percutaneous transluminal angioplasty in the treatment of lower-extremity ischemia J. Vasc. Surg. 10 57–67 Occurrence Handle10.1067/mva.1989.vs0100057 Occurrence Handle1:STN:280:BiaA3M7ns1w%3D Occurrence Handle2526233
K Mizuno A Jurita N Imazeki (1984) ArticleTitlePathologic finding after percutaneous transluminal angioplasty Br. Heart J. 18 476–484
GE Austin NB Ratliff J Hollman S Tabie DF Philips (1985) ArticleTitleIntimal proliferation of smooth muscle cells as an explanation for recurrent coronary artery stenosis after percutaneous transluminal angioplasty J. Am. Coll. Cardiol. 6 369–375 Occurrence Handle1:STN:280:BiqB283js1E%3D Occurrence Handle3160756
BF Walker (1989) ArticleTitle“Crackers, breakers, stretchers, drillers, scrapers, shavers, burners, welders and melters” — the future treatment of atherosclerotic coronary artery disease? A clinical morphologic assessment J. Am. Coll. Cardiol. 13 969–987
N Zorger C Manke M Lenhart et al. (2002) ArticleTitlePeripheral arterial balloon angioplasty: effect of short versus long balloon inflation times on the morphologic results J. Vasc. Interv. Radiol. 13 355–359
M Izumi E Tsuchikane M Funamoto et al. (2001) ArticleTitleFinal results of the CAPAS trial Am. Heart J. 142 782–789 Occurrence Handle10.1067/mhj.2001.119129 Occurrence Handle1:STN:280:DC%2BD3MngvFKntQ%3D%3D Occurrence Handle11685163
AS Kurbaan RA Foale U Sigwart (2000) ArticleTitleCutting balloon angioplasty for in-stent restenosis Cathet. Cardiovasc. Intervent. 50 480–483 Occurrence Handle10.1002/1522-726X(200008)50:4<480::AID-CCD24>3.0.CO;2-2 Occurrence Handle1:STN:280:DC%2BD3cvjsFSmsg%3D%3D
D Martinez J Goicolea F Alfonzo et al. (1996) ArticleTitleIntravascular ultrasound findings after cutting balloon angioplasty [abstract] Eur. Heart J. 17 IssueIDSuppl 188
O Ergene BY Seyithanoglu A Tastan et al. (1998) ArticleTitleComparison of angiographic and clinical outcome after cutting balloon and conventional balloon angioplasty in vessels smaller than 3 mm in diameter: a randomized trial J. Invasive Cardiol. 10 70–75 Occurrence Handle10762769
T Kondo K Kawaguchi Y Awaji M Mochizuki (1997) ArticleTitleImmediate and chronic results of cutting balloon angioplasty: a matched comparison with conventional angioplasty Clin. Cardiol. 20 459–463 Occurrence Handle1:STN:280:ByiB2sbptVA%3D Occurrence Handle9134278
C Engelke C Sandhu RA Morgan AM Belli (2002) ArticleTitleUsing 6-mm cutting balloon angioplasty in patients with resistant peripheral artery stenosis: preliminary results A.J.R. Am. J. Roentgenol. 179 619–623
C Engelke RA Morgan AM Belli (2002) ArticleTitleCutting balloon percutaneous transluminal angioplasty for salvage of lower limb arterial bypass grafts: feasibility Radiology 223 106–114 Occurrence Handle11930054
KM Kasirajan PA Schneider (2004) ArticleTitleEarly outcome of “cutting” balloon angioplasty for infrainguinal vein graft stenosis J. Vasc. Surg. 39 702–708 Occurrence Handle10.1016/j.jvs.2003.10.046 Occurrence Handle15071429
GM Ansel NS Sample III CF Botti SuffixJr AJ Tracy MJ Silver BJ Marshall BS George (2004) ArticleTitleCutting balloon angioplasty of the popliteal and infrapopliteal vessels for symptomatic limb ischemia Cathet. Cardiovasc. Interv. 64 1–4
OF Bertrand R Mongrain L Soualmi et al. (1998) ArticleTitleDevelopment of coronary aneurysm after cutting balloon angioplasty: assessment by intracoronary ultrasound Cathet. Cardiovasc. Diagn. 44 449–452 Occurrence Handle10.1002/(SICI)1097-0304(199808)44:4<449::AID-CCD20>3.3.CO;2-8 Occurrence Handle1:STN:280:DyaK1czotVSksQ%3D%3D Occurrence Handle9716216
L Mauri R Bonan BH Weiner et al. (2002) ArticleTitleCutting balloon angioplasty for the prevention of restenosis: results of the Cutting Balloon Global Randomized Trial Am. J. Cardiol. 90 1079–1083 Occurrence Handle10.1016/S0002-9149(02)02773-X Occurrence Handle12423707
AE Ajani HS Kim M Castagna et al. (2001) ArticleTitleClinical utility of the cutting balloon J. Invasive Cardiol. 13 554–557 Occurrence Handle1:STN:280:DC%2BD3MznvFWktA%3D%3D Occurrence Handle11435645
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Rabbi, J.F., Kiran, R.P., Gersten, G. et al. Early Results with Infrainguinal Cutting Balloon Angioplasty Limits Distal Dissection. Ann Vasc Surg 18, 640–643 (2004). https://doi.org/10.1007/s10016-004-0103-9
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10016-004-0103-9