Reproductive accuracy of safety valve two-phase mass flow capacity models in case of air/water, resp., viscous liquid flow duty

Wiedergabegenauigkeit von Modellen für die Massendurchsatzkapazität von Sicherheitsventilen bei Zweiphasenströmung von Luft/Wasser bzw. viskoser Flüssigkeit

  • Originalarbeiten/Originals
  • Published:
Forschung im Ingenieurwesen Aims and scope Submit manuscript

Abstract

On the basis of integral statistical key figures, the reproductive quality of the Extended Maximum Disequilibrium Method as proposed by Wieczorek [?] is in the range of the liquid phase viscosity of up to 2800 mPa s in comparison with that exhibited by the models according to ISO/CD 4126-10 [?], Lenzing [?], Leung [?], Gosslau and Weyl [?], resp., Fauske [?] higher and in parallel so far unique to achieve under all conditions an oversizing of the relief area. This result is partially offset by a comparatively higher average uncertainty, resp., larger relief area oversizing in the range of viscosities of up to 100 mPa s.

The apportionment of the integral statistical figures as a function of the stagnation air mass quality shows that most of the methods – independently of the liquid viscosity level – feature the largest deviations, resp., oversizing in the range of mass flow qualities between 0.1 and 1%. This is unfortunately just the discharge mass flow quality used in sizing in case of partially liquid loaded reactor top venting.

Zusammenfassung

Auf der Grundlage von integralen statistischen Kennzahlen folgt, dass das Erweiterte Maximale Ungleichgewichtsmodell gemäss Wieczorek [?] bei der Gegebenheit von Flüssigphaseviskositäten von bis zu 2800 mPa s anders als die Methoden gemäss ISO/CD 4126-10 [?], Lenzing [?], Leung [?], Gosslau und Weyl [?] bzw. Fauske [?] insgesamt eine höhere Wiedergabegenauigkeit und gleichzeitig immer eine sicherheitstechnisch vorsorgliche Überdimensionierung des Entlastungsquerschnittes gewährleistet. Damit geht allerdings eine vergleichsweise höhere Ungenauigkeit bzw. grössere Überdimensionierung im Bereich von Flüssigphaseviskositäten bis 100 MPa s einher.

Die Darstellung der statistischen Kennzahlen in Abhängigkeit von dem Stagnationmassenluftgehalt zeigt, dass bei der Mehrzahl der Methoden – unabhängig von der Flüssigphaseviskosität – die grössten Abweichungen bzw. Überdimensionierungen im Bereich der Massenluftgehalte von 0.1 bis 1% auftreten. Dies ist aber ausgerechnet der Bereich, der bei der Bemessung der Sicherheitseinrichtungen im Fall der kopfseitigen Entlastung von anfänglich teilgefüllten Reaktoren zugrunde gelegt wird.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Lenzing T, Friedel L (2000) Modelle für den über Vollhubsicherheitsventile abführbaren Massenstrom bei Einphasen- und Zweiphasenströmung. Techn Überw 41(5):15–23

    Google Scholar 

  2. ISO/CD 4126-10 (2003) Sizing of safety valves and connected inlet and outlet lines for gas/liquid two-phase flow

  3. API RP 520 (2000) Sizing, selection, and installation of pressure relieving devices in refineries. Part I – Sizing and selection

  4. Leung JC (1995) The Omega method for discharge rate evaluation. Intern Symp Runaway Reactions and Pressure Relief Design, Boston, pp 367–393

  5. Leung JC (2003) Discharge through relief devices – discharge coefficient and non-equilibrium effect. EDUG Meeting

  6. Gosslau W, Weyl R (1989) Strömungsdruckverluste und Reaktionskräfte in Rohrleitungen bei Notentspannung durch Sicherheitsventile und Berstschreiben. Sonderdrucke Techn Überw 30(5-9), (3. ergänzte Auflage 1992)

  7. Wieczorek M (2005) Verbesserte Bemessungsmethode für Vollhubsicherheitsventile bei nicht nachverdampfender Zweiphasenströmung. Techn Überw 46(1):27–33

    MathSciNet  Google Scholar 

  8. Leung JC, Epstein M (1990) A generalised correlation for two-phase non flashing homogeneous choked flow. J Heat Transf Trans ASME 112:528–530

    Article  Google Scholar 

  9. Fauske HK (1998) An easy to use two-phase flow model including subcooling, nonequilibrium, and viscous effects. In: Proc 2nd Intern Symp Runaway Reactions, New Orleans

  10. Darby R, Molavi K (1997) Viscosity correction factor for safety relief valves. Proc Safety Prog 16(2):80–82

    Article  Google Scholar 

  11. Derlien H, Friedel L (2004) Accuracy of safety valve two-phase mass flow capacity sizing in case of single-component steam/water, resp., refrigerant R 134a flow duty. Paper Europ Two-Phase Flow Group Meeting, Genova

  12. Lenzing T (2001) Theoretische und experimentelle Untersuchungen zu dem über Vollhubsicherheitsventile abführbaren Massenstrom bei Einphasen- und Zweiphasenströmung. Fortschr.-Ber. VDI Reihe 3(718)

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Moncalvo, D., Friedel, L. Reproductive accuracy of safety valve two-phase mass flow capacity models in case of air/water, resp., viscous liquid flow duty. Forsch Ingenieurwes 70, 133–138 (2005). https://doi.org/10.1007/s10010-006-0023-7

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10010-006-0023-7

Keywords

Navigation