Abstract
This work deals about the evaluation and improvement of analytical and electrochemical features of chemically modified electrode based on dihexadecyl hydrogen phosphate (DPH) and carbonaceous materials. The electrochemical features of films obtained were evaluated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Between the modifications evaluated, the glassy carbon electrode (GCE) modified with CB and DPH (DHP-CB/GCE) showed lower resistance to charge transfer and higher electron transfer rate. Additionally, the highest current of U(VI) was obtained with DHP-CB/GCE in a very stable way, the process present quasi-reversible behavior and it is controlled by a mixture of diffusion and absorption. The best instrumental conditions for U(VI) determination were obtained applying frequency of 15 Hz, amplitude of 100 mV, and deposition potential of − 0.1 V (by square wave cathodic stripping voltammetry). Among the electrolyte compositions (acetate and citrate buffers), ionic strength (from 0.10, 0.15, to 0.20 mol L−1), and pH (from 3.6 to 5.6) evaluated, the highest current of U(VI) were obtained in 0.15 mol L−1 of acetate buffer, pH 5.6. The method was accurate, linear, and sensitive (detection limit of 0.088 μg L−1 using 300 s of deposition).
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
ATSDR (2013) Toxicological profile for uranium. Department of health and human services, Public Health Service, Atlanta
Keith LS, Faroon OM, Fowler BA (2007) Uranium. In: Nordberg GF, Fowler BA, Nordberg M, Friberg LT (eds) Handbook on the toxicology of metals, 3rd edn. Academic Press, Burlington, pp 881–903
CONAMA (2005) Resolution No. 357/2005. March 17, 2005. Published in DOU no. 053, on march 18, 2005, pages 58-63
EPA (2001) Radionuclides rule: a quick reference guide. U.S. Environmental Protection Agency
WHO (2012) Uranium in drinking-water: background document for development of WHO guidelines for drinking-water quality. World Health Organization
AOAC (2000) Método 993.14 - Trace elements in waters and wastewaters. Inductively coupled plasma-mass spectrometric method
APHA (2012) Metals by inductively coupled plasma/mass spectrometry. In: Standard methods for the examination of water and wastewater, 22nd ed. American public health association
ASTM (2016) ASTM D5673 - Standard test method for elements in water by inductively coupled plasma—mass spectrometry
Khan MH, Warwick P, Evans N (2006) Spectrophotometric determination of uranium with arsenazo-III in perchloric acid. Chemosphere 63(7):1165–1169
Yousefi SR, Ahmadi SJ, Shemirani F, Jamali MR, Salavati-Niasari M (2009) Simultaneous extraction and preconcentration of uranium and thorium in aqueous samples by new modified mesoporous silica prior to inductively coupled plasma optical emission spectrometry determination. Talanta 80(1):212–217
Santos JS, Teixeira LSG, dos Santos WNL, Lemos VA, Godoy JM, Ferreira SL (2010) Uranium determination using atomic spectrometric techniques: an overview. Anal Chim Acta 674(2):143–156
de Oliveira C, Aquino SA, Giacomini GX et al (2019) Uranium determination in industrial effluents by voltammetric method using triazene 1-oxide as an alternative binder. Int J Environ Sci Technol:1–10. https://doi.org/10.1007/s13762-019-02549-3
Wang J, Lu J, Larson DD, Olsen K (1995) Voltammetric sensor for uranium based on the propyl gallate-modified carbon paste electrode. Electroanalysis 7:247–250
Yantasee W, Lin Y, Fryxell GE, Wang Z (2004) Carbon paste electrode modified with carbamoylphosphonic acid functionalized mesoporous silica: a new mercury-free sensor for uranium detection. Electroanalysis 16:870–873
Dimovasilis PA, Prodromidis MI (2011) An electrochemical sensor for trace uranium determination based on 6-O-palmitoyl-L-ascorbic acid-modified graphite electrodes. Sensors Actuators B Chem 156:689–694
Golikand AN, Asgari M, Maragheh MG, Lohrasbi E (2009) Carbon nanotube-modified glassy carbon electrode for anodic stripping voltammetric detection of Uranyle. J Appl Electrochem 39:65–70
Guin SK, Parvathi K, Ambolikar AS et al (2015) An insight into the electrocatalysis of uranyl sulphate on gold nanoparticles modified glassy carbon electrode. Electrochim Acta 154:413–420
Nassab HR, Souri A, Javadian A, Amini MK (2015) A novel mercury-free stripping voltammetric sensor for uranium based on electropolymerized N-phenylanthranilic acid film electrode. Sensors Actuators B Chem 215:360–367
Ziółkowski R, Górski Ł, Malinowska E (2017) Carboxylated graphene as a sensing material for electrochemical uranyl ion detection. Sensors Actuators B Chem 238:540–547
Becker A, Tobias H, Porat Z, Mandler D (2008) Detection of uranium(VI) in aqueous solution by a calix[6]arene modified electrode. J Electroanal Chem 621:214–221
Merli D, Protti S, Labò M, Pesavento M, Profumo A (2016) A ω-mercaptoundecylphosphonic acid chemically modified gold electrode for uranium determination in waters in presence of organic matter. Talanta 151:119–125
Becker A, Tobias H, Mandler D (2009) Electrochemical determination of uranyl ions using a self-assembled monolayer. Anal Chem 81:8627–8631
Shervedani RK, Mozaffari SA (2005) Preparation and electrochemical characterization of a new nanosensor based on self-assembled monolayer of cysteamine functionalized with phosphate groups. Surf Coatings Technol 198:123–128
Ziółkowski R, Górski Ł, Oszwałdowski S, Malinowska E (2012) Electrochemical uranyl biosensor with DNA oligonucleotides as receptor layer. Anal Bioanal Chem 402:2259–2266
Jarczewska M, Ziółkowski R, Górski Ł, Malinowska E (2014) Electrochemical uranyl cation biosensor with DNA oligonucleotides as receptor layer. Bioelectrochemistry 96:1–6
Wu Y, Hu S (2007) Direct electrochemistry of glucose oxidase in a colloid Au–dihexadecylphosphate composite film and its application to develop a glucose biosensor. Bioelectrochemistry 70(2):335–341
Wu K, Sun Y, Hu S (2003) Development of an amperometric indole-3-acetic acid sensor based on carbon nanotubes film coated glassy carbon electrode. Sensors Actuators B Chem 96:658–662
Sanz-Medel A, Fernandez de la Campa M del R, Gonzalez EB, Fernandez-Sanchez ML (1999) Organised surfactant assemblies in analytical atomic spectrometry. Spectrochim Acta Part B At Spectrosc 54:251–287
Ibáñez-Redín G, Silva TA, Vicentini FC, Fatibello-Filho O (2018) Effect of carbon black functionalization on the analytical performance of a tyrosinase biosensor based on glassy carbon electrode modified with dihexadecylphosphate film. Enzym Microb Technol 116:41–47
Yao S, Xu J, Wang Y et al (2006) A highly sensitive hydrogen peroxide amperometric sensor based on MnO2 nanoparticles and dihexadecyl hydrogen phosphate composite film. Anal Chim Acta 557:78–84
Garcia LLC, Figueiredo-Filho LCS, Oliveira GG et al (2013) Square-wave voltammetric determination of paraquat using a glassy carbon electrode modified with multiwalled carbon nanotubes within a dihexadecylhydrogenphosphate (DHP) film. Sensors Actuators B Chem 181:306–311
Geng M, Yang YJ, Hu S et al (2009) The voltammetric determination of phenolphthalein on multi-walled carbon nanotube-DHP composite film-modified glassy carbon electrode. Fullerenes, Nanotub Carbon Nanostructures 17:285–297
Deroco PB, Rocha-Filho RC, Fatibello-Filho O (2018) A new and simple method for the simultaneous determination of amoxicillin and nimesulide using carbon black within a dihexadecylphosphate film as electrochemical sensor. Talanta 179:115–123
Hu X, Wang P, Yang J, Zhang B, Li J, Luo J, Wu K (2010) Enhanced electrochemical detection of erythromycin based on acetylene black nanoparticles. Colloids Surfaces B Biointerfaces 81(1):27–31
Maciel JV, Silva TA, Dias D, Fatibello-Filho O (2018) Electroanalytical determination of eugenol in clove oil by voltammetry of immobilized microdroplets. J Solid State Electrochem 22:2277–2285
Noskova GN, Zakharova EA, Kolpakova NA, Kabakaev AS (2012) Electrodeposition and stripping voltammetry of arsenic(III) and arsenic(V) on a carbon black–polyethylene composite electrode in the presence of iron ions. J Solid State Electrochem 16:2459–2472
Zhou K, Tian Y, Ma H et al (2018) Photoelectrocatalytic performance of conductive carbon black-modified Ti/F-PbO2 anode for degradation of dye wastewater (reactive brilliant blue KN-R). J Solid State Electrochem 22:1131–1141
Zhutaeva GV, Bogdanovskaya VA, Davydova ES et al (2014) Kinetics and mechanism of oxygen electroreduction on Vulcan XC72R carbon black modified by pyrolysis products of cobalt 5,10,15,20-tetrakis(4-methoxyphenyl)porphyrine in a broad pH interval. J Solid State Electrochem 18:1319–1334
Maciel JV, Fava EL, Silva TA et al (2017) A combination of voltammetry of immobilized microparticles and carbon black-based crosslinked chitosan films deposited on glassy carbon electrode for the quantification of hydroquinone in dermatologic cream samples. J Solid State Electrochem 21:2859–2868
Fu Y, Liu Y, Li Y et al (2015) Synergistic electrocatalysis of N,N′-bis(salicylidene)-ethylenediamine-cobalt(II) and conductive carbon black (BP) for high efficient CO2 electroreduction. J Solid State Electrochem 19:3355–3363
Janegitz BC, Marcolino-Junior LH, Campana-Filho SP et al (2009) Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan. Sensors Actuators B Chem 142:260–266
Chaisiwamongkhol K, Batchelor-McAuley C, Sokolov SV et al (2017) Optimising carbon electrode materials for adsorptive stripping voltammetry. Appl Mater Today 7:60–66
Phillips C, Al-Ahmadi A, Potts S-J et al (2017) The effect of graphite and carbon black ratios on conductive ink performance. J Mater Sci 52:9520–9530
Wang F, Hu S (2005) Electrochemical reduction of dioxygen on carbon nanotubes–dihexadecyl phosphate film electrode. J Electroanal Chem 580:68–77
Ardila JA, Oliveira G, Medeiros A, Fatibello-filho O (2014) Square-wave adsortive stripping voltammetric determination of nanomolar levels of bezafibrate using a glassy carbon electrode modified with multi-walled carbon nanotubes within a dihexadecyl hydrogen phosphate film. Analyst 139(7):1762–1768
Brett CMA, Brett AMO (1993) Electrochemistry: principles, methods and aplication, 1st edn. Oxford Science Publications
Domingos JB, Longhinotti E, Machado VG, Nome F (2003) A química dos ésteres de fosfato. Quim Nova 26:745–753
Carmona-Ribeiro AM (1990) Dihexadecylphosphate bilayers: interbilayer interactions and intrabilayer structure. J Colloid Interface Sci 139:343–350
Tricot Y-M, Furlong DN, Sasse WHF et al (1984) Dihexadecylphosphate vesicle dispersions—preparation, physical properties, and interactions with cationic components used in the solar photolysis of water. J Colloid Interface Sci 97:380–391
Djogić R, Branica M (1995) Square-wave cathodic stripping voltammetry of hydrolyzed uranyl species. Anal Chim Acta 305:159–164
Martell AE, Smith RM (1977) Critical stability constants. Vol. 3 : Other organic ligands. Plenum Publishing Corporation
AOAC (2016) Guidelines for standard method performance requirements (appendix F). In: Official methods of analysis of AOAC International. AOAC International, Gaithersburg
Acknowledgments
The authors would like to thank CEME-SUL FURG and SDECT.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
ESM 1
(DOCX 832 kb)
Rights and permissions
About this article
Cite this article
de Araujo Aquino, S., Maciel, J.V. & Dias, D. Chemically modified electrode based on dihexadecyl hydrogen phosphate and carbonaceous materials: improvement of analytical and electrochemical features applied to uranium determination. J Solid State Electrochem 24, 1981–1989 (2020). https://doi.org/10.1007/s10008-020-04501-9
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10008-020-04501-9