Abstract
Preanodized screen printed carbon electrode (SPCE) has been utilized for the detection of propofol. Here the preanodized SPCE possess the specific functional groups which help the detection and determination of propofol. The proposed SPCE shows a clear oxidation peak for the detection of propofol in pH 7.0 phosphate buffer solutions. Interestingly, it shows a well-defined individual oxidation peak for the detection of propofol in the presence interferences (mixture of ascorbic acid, dopamine, and uric acid). This type of pretreated SPCE successfully enhances the electrooxidation current and overcomes the interference effects and clearly exhibits the signals for the propofol detection using cyclic voltammetry and flow injection analysis techniques. The preanodized SPCE shows the electrooxidation signals for the propofol detection in the linear range of 0.09 to 0.90 μM, respectively. Further, the sensitivity of the proposed electrode for the propofol detection is found to be 3.6 μA μM−1.
Similar content being viewed by others
References
Shiffman MA (2003) Inter J Cosmet Surg Aesthet Dermat 5:83
Niermeijer JMF, Uiterwaal CSPM, Van Donselaar CA (2003) J Neurol 250:1237
Iacobone CF, Gorgoglione E, Pellegrini M, Tafani A, Volpe C, Conti G (2005) Miner Anestesiolog 71:367
Sajedi P, Yaraghi A, Niareisy L (2006) J Res Med Sci 11:160
Häser I (2008) Klinikarzt 37:404
Gussow L MD (2009) Emerg Med News 31:16
McCarver LMS (2010) Plast Surg Nurs 30:29
Charatan F (2009) BMJ 339:b3673
Alcoholism & Drug Abuse weekly (2009) A Wiley Periodicals, Inc, vol 21, No. 34, p 5
Alcoholism & Drug Abuse weekly (2009) A Wiley Periodicals, Inc, vol 21, No. 34, p 7
Uebel RA, Wium CA, Hawtrey AO, Coetzee J (1990) J Chromatogr Biomed Sci Appl 526:293
Mazzi G, Schinella M (1990) J Chromatogr Biomed Sci Appl 528:537
Trocewicz J, Suprynowicz Z, Markowicz J (1990) J Chromatogr B 685:129
Dowrle RH, Ebling WF, Mandem JW, Stanski DR (1996) J Chromatogr B 678:279
Favetta P, Guitton J, Degoute CS, Van Daele L, Boulieu R (2000) J Chromatogr B 742:25
Pissinis DE, Marioli JM (2007) J Liq Chromatogr Relat Technol 30:1787
Seno H, He YL, Tashiro C, Ueyama H, Mashimo T (2002) J Anesth 16:87
Nagaoka T, Yoshino T (1986) Anal Chem 58:1037
Sullivan MG, Kötz R, Haas O (2000) J Electrochem Soc 147:308
Jovanovi C, Dusˇan Tripkovi VM, Tripkovi D, Kowal C, Stoch A (2005) Electrochem Commun 7:1039
Shi K, Shiu KK (2001) Electroanalysis 13:1319
Thiagarajan S, Tsai TH, Chen SM (2009) Biosens Bioelectron 24:2712
Yang CC, Kumar AS, Zen JM (2006) Electroanalysis 18:64
Kumar AS, Zen JM (2002) Electroanalysis 14:671
Prasad KS, Muthuraman G, Zen JM (2008) Electrochem Commun 10:559
Chandrasekaran S, Sundararajan S (2004) Surf Coat Technol 188:581
Chen YH, Huang WH (2004) Meas Sci Technol 15:2005
Méndez-Vilas A, Bruque JM, ML Gonzá lez-Martín (2007) Ultramicroscopy 107:617
Wu YL, Chen Z, Zeng XT (2008) Appl Surf Sci 254:6952
Ozoemena KI, Nkosi D, Pillay J (2008) Electrochim Acta 53:2844
Agboola BO, Vilakazi SL, Ozoemena KI (2009) J Solid State Electrochem 13:1367
Acknowledgment
This work was supported by grants from National Science Council (NSC) of Taiwan (ROC).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Thiagarajan, S., Cheng, CY., Chen, SM. et al. Electrochemical detection of propofol at the preanodized carbon electrode. J Solid State Electrochem 15, 781–786 (2011). https://doi.org/10.1007/s10008-010-1160-3
Received:
Revised:
Accepted:
Published:
Issue Date: