Skip to main content

Advertisement

Log in

Identification of anterior loop in different populations to avoid nerve injury during surgical procedures—a systematic review and meta-analysis

  • Review Article
  • Published:
Oral and Maxillofacial Surgery Aims and scope Submit manuscript

Abstract

Exact recognition of the anterior loop is very important to avert any injury to the neurovascular bundle during surgical procedures. The purpose of this review was to evaluate the prevalence and length of the anterior loop in different populations. A comprehensive search of Medline/Pubmed and Cochrane database was done. The focused question was the presence of anterior loop (including loop length) of the inferior alveolar nerve in mental foramen region in CBCT images of the various subjects. Articles related to the presence of anterior loop (including loop length) were only included. Initial literature search resulted in 3024 papers, after removing duplicate articles, 2821 articles were left. Two thousand seven hundred eighty-four articles were further excluded by the reviewers after screening the abstracts which resulted in 37 studies. Hand searching resulted in 2 additional papers. Seven full-text articles were excluded for not fulfilling the inclusion criteria. Finally, 32 articles were included in the review. Two thousand five hundred three subjects with anterior loop were found, which approximates 38% with 48.4% bilateral, 27.8% right side, and 23.8% left side. The loop distribution in males and females was also found to be different. There was highly significant (P < 0.001; I2 = 98.81%) heterogeneity found in the included studies. Variations were found in the prevalence, length, gender, and side distribution of anterior loop in various populations. This systematic review highly recommends not relying on any average values and the clinician should compulsorily make use of imaging modalities available in each and every case, wherever surgical procedure is to be performed near mental foramen region.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Cantekin K, Sekerci A (2014) Evaluation of the accessory mental foramen in a pediatric population using cone-beam computed tomography. J Clin Pediatr Dent 39(1):85–89. https://doi.org/10.17796/jcpd.39.1.rxtrn82463716907

    Article  CAS  PubMed  Google Scholar 

  2. Rosa MB, Sotto-Maior BS, Machado Vde C, Francischone CE (2013) Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography. Int J Oral Maxillofac Implants 28(2):388–392. https://doi.org/10.11607/jomi.2648

    Article  PubMed  Google Scholar 

  3. Filo K, Schneider T, Locher MC, Kruse AL, Lübbers H (2014) The inferior alveolar nerve’s loop at the mental foramen and its implications for surgery. J Am Dent Assoc 145(3):260–269. https://doi.org/10.14219/jada.2013.34

    Article  PubMed  Google Scholar 

  4. Jalbout Z, Tabourian G (2004) Glossary of implant dentistry, vol 16. International Congress of Oral Implantologists, Upper Montclair

    Google Scholar 

  5. Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res 14(4):464–471. https://doi.org/10.1034/j.1600-0501.2003.00869.x

    Article  PubMed  Google Scholar 

  6. Phraisukwisarn P, Asvanund P, Kretapirom K (2017) Measurement of anterior loop of inferior alveolar nerve using cone beam computed tomography. M Dent J 37(1):83–89

    Google Scholar 

  7. Jones BM, Vesely MJ (2006) Osseous genioplasty in facial aesthetic surgery—a personal perspective reviewing 54 patients. J Plast Reconstr Aesthet Surg 59(11):1177–1187. https://doi.org/10.1016/j.bjps.2006.04.011

    Article  CAS  PubMed  Google Scholar 

  8. Hoenig JF (2007) Sliding osteotomy genioplasty for facial aesthetic balance: 10 years of experience. Aesthet Plast Surg 31(14):384–391. https://doi.org/10.1007/s00266-006-0177-6

    Article  Google Scholar 

  9. Sati S, Havlik RJ (2011) An evidence-based approach to genioplasty. Plast Reconstr Surg 127(2):898–904. https://doi.org/10.1097/prs.0b013e31820461c5

    Article  CAS  PubMed  Google Scholar 

  10. Westermark A, Bystedt H, von Konow L (1998) Inferior alveolar nerve function after mandibular osteotomies. Br J Oral Maxillofac Surg 36(6):425–428. https://doi.org/10.1016/s0266-4356(98)90457-0

    Article  CAS  PubMed  Google Scholar 

  11. Song Q, Li S, Patil PM (2014) Inferior alveolar and mental nerve injuries associated with open reduction and internal fixation of mandibular fractures: a seven year retrospective study. J Craniomaxillofac Surg 42(7):1378–1381. https://doi.org/10.1016/j.jcms.2014.03.029

    Article  PubMed  Google Scholar 

  12. Wismeijer D, van Waas MA, Vermeeren JI, Kalk W (1997) Patients’ perception of sensory disturbances of the mental nerve before and after implant surgery: a prospective study of 110 patients. Br J Oral Maxillofac Surg 35(4):254–259. https://doi.org/10.1016/s0266-4356(97)90043-7

    Article  CAS  PubMed  Google Scholar 

  13. Dao TT, Mellor A (1998) Sensory disturbances associated with implant surgery. Int J Prosthodont 11(5):462–469

    CAS  PubMed  Google Scholar 

  14. Bartling R, Freeman K, Kraut RA (1999) The incidence of altered sensation of the mental nerve after mandibular implant placement. J Oral Maxillofac Surg 57(12):1408–1412. https://doi.org/10.1016/s0278-2391(99)90720-6

    Article  CAS  PubMed  Google Scholar 

  15. Walton JN (2000) Altered sensation associated with implants in the anterior mandible: a prospective study. J Prosthet Dent 83(4):443–449. https://doi.org/10.1016/s0022-3913(00)70039-4

    Article  CAS  PubMed  Google Scholar 

  16. Apostolakis D, Brown JE (2012) The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging. Clin Oral Implants Res 23(9):1022–1030. https://doi.org/10.1111/j.1600-0501.2011.02261.x

    Article  PubMed  Google Scholar 

  17. Uchida Y, Yamashita Y, Goto M, Hanihara T (2007) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region. J Oral Maxillofac Surg 65(4):1772–1779. https://doi.org/10.1016/j.joms.2008.05.352

    Article  PubMed  Google Scholar 

  18. de Oliveira-Santos C, Souza PH, de Azambuja B-CS, Stinkens L, Moyaert K, Rubira-Bullen IRF, Jacobset R (2012) Assessment of variations of the mandibular canal through cone beam computed tomography. Clin Oral Investig 16(2):387–393. https://doi.org/10.1007/s00784-011-0544-9

    Article  PubMed  Google Scholar 

  19. Iyengar AR, Patil S, Nagesh KS, Mehkri S, Manchanda S (2013) Detection of anterior loop and other patterns of entry of mental nerve into the mental foramen: a radiographic study in panoramic images. J Dent Implant 3(1):21–25

    Article  Google Scholar 

  20. Ito K, Gomi Y, Sato S, Arai Y, Shinoda K (2001) Clinical application of a new compact CT system to assess 3-D images for the preoperative treatment planning of implants in the posterior mandible: a case report. Clin Oral Implants Res 12(5):539–542. https://doi.org/10.1034/j.1600-0501.2001.120516.x

    Article  CAS  PubMed  Google Scholar 

  21. Baumgaertel S, Palomo JM, Palomo L, Hans MG (2009) Reliability and accuracy of cone-beam computed tomography dental measurements. Am J Orthod Dentofac Orthop 136(1):19–25. https://doi.org/10.1016/j.ajodo.2007.09.016

    Article  Google Scholar 

  22. Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group (2010) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg 8(5):336–341. https://doi.org/10.1016/j.ijsu.2010.02.007

    Article  PubMed  Google Scholar 

  23. Stone PW (2002) Popping the (PICO) question in research and evidence-based practice. Appl Nurs Res 15(3):197–198. https://doi.org/10.1053/apnr.2002.34181

    Article  PubMed  Google Scholar 

  24. Institute TJB (2014) Joanna Briggs Institute Reviewers’ Manual: 2014 edition/Supplement, vol 5005. The University of Adelaide, South Australia

    Google Scholar 

  25. Sinha S, Kandula S, Sangamesh NC, Rout P, Mishra S, Bajoria AA (2019) Assessment of the anterior loop of the mandibular canal using cone-beam computed tomography in Eastern India: a record-based study. J Int Soc Prevent Communit Dent 9(3):290–295

    Article  Google Scholar 

  26. Raju N, Zhang W, Jadhav A, Ioannou A, Eswaran S, Weltman R (2019) Cone beam computed tomography analysis of the prevalence, length, and passage of the anterior loop of the mandibular canal. J Oral Implant 45(6):463–468. https://doi.org/10.1563/aaid-joi-D-18-00236

    Article  Google Scholar 

  27. Xie L, Li T, Chen J, Yin D, Wang W, Xie Z (2019) Cone-beam CT assessment of implant-related anatomy landmarks of the anterior mandible in a Chinese population. Surg Radiol Anat 41(8):927–934. https://doi.org/10.1007/s00276-019-02250-7

    Article  PubMed  Google Scholar 

  28. Wei X, Gu P, Hao Y, Wang J (2019) Detection and characterization of anterior loop, accessory mental foramen, and lateral lingual foramen by using cone beam computed tomography. J Prosthet Dent 124:365–371. https://doi.org/10.1016/j.prosdent.2019.06.026

    Article  PubMed  Google Scholar 

  29. Rodricks D, Phulambrikar T, Singh SK, Gupta A (2018) Evaluation of incidence of mental nerve loop in Central India population using cone beam computed tomography. Indian J Dent Res 29(5):627–633

    Article  Google Scholar 

  30. Vieira CL, Veloso SD, Lopes FF (2018) Location of the course of the mandibular canal, anterior loop and accessory mental foramen through cone-beam computed tomography. Surg Radiol Anat 40(12):1411–1417. https://doi.org/10.1007/s00276-018-2081-6

    Article  PubMed  Google Scholar 

  31. Prakash O, Srivastava PK, Jyoti B, Mushtaq R, Vyas T, Usha P (2018) Radiographic evaluation of anterior loop of inferior alveolar nerve: a cone-beam computer tomography study. Niger J Surg 24(2):90–94. https://doi.org/10.4103/njs.NJS_1_18

    Article  PubMed  PubMed Central  Google Scholar 

  32. Christopher JP, Marimuthu T, Krithika C, Devadoss P, Kumar SM (2018) Prevalence and measurement of anterior loop of the mandibular canal using CBCT: a cross sectional study. Clin Implant Dent Relat Res 20(4):531–534. https://doi.org/10.1111/cid.12609

    Article  Google Scholar 

  33. do Carmo Oliveira M, Tedesco TK, Gimenez T, Allegrini S Jr (2018) Analysis of the frequency of visualization of morphological variations in anatomical bone features in the mandibular interforaminal region through cone-beam computed tomography. Surg Radiol Anat 40(10):1119–1131. https://doi.org/10.1007/s00276-018-2040-2

    Article  PubMed  Google Scholar 

  34. Krishnan U, Monsour P, Thaha K, Lalloo R, Moule A (2018) A limited field cone-beam computed tomography–based evaluation of the mental foramen, accessory mental foramina, anterior loop, lateral lingual foramen, and lateral lingual canal. J Endod 44(6):946–951. https://doi.org/10.1016/j.joen.2018.01.013

    Article  PubMed  Google Scholar 

  35. Goller Bulut D, Köse E (2018) Available bone morphology and status of neural structures in the mandibular interforaminal region: three-dimensional analysis of anatomical structures. Surg Radiol Anat 40(11):1243–1252. https://doi.org/10.1007/s00276-018-2039-8

    Article  PubMed  Google Scholar 

  36. Siddiqui Z, Rai S, Ranjan V (2018) Efficacy and evaluation of cone beam computed tomography in determining the prevalence and length of anterior loop of inferior alveolar nerve in north Indian population. J Indian Acad Oral Med Radiol 30(1):32–37

    Article  Google Scholar 

  37. Shaban B, Khajavi A, Khaki N, Mohiti Y, Mehri T, Kermani H (2017) Assessment of the anterior loop of the inferior alveolar nerve via cone-beam computed tomography. J Korean Assoc Oral Maxillofac Surg 43(6):395–400. https://doi.org/10.5125/jkaoms.2017.43.6.395

    Article  PubMed  PubMed Central  Google Scholar 

  38. Wong SK, Patil PG (2018) Measuring anterior loop length of the inferior alveolar nerve to estimate safe zone in implant planning: a CBCT study in a Malaysian population. J Prosthet Dent 120(2):210–213. https://doi.org/10.1016/j.prosdent.2017.10.019

    Article  PubMed  Google Scholar 

  39. Al-Mahalawy H, Al-Aithan H, Al-Kari B, Al-Jandan B, Shujaat S (2017) Determination of the position of mental foramen and frequency of anterior loop in Saudi population. A retrospective CBCT study. Saudi Dent J 29(1):29–35. https://doi.org/10.1016/j.sdentj.2017.01.001

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  40. Kheir MK, Sheikhi M (2017) Assessment of the anterior loop of mental nerve in an Iranian population using cone beam computed tomography scan. Dent Res J 14(6):418–422

    Article  Google Scholar 

  41. Velasco-Torres M, Padial-Molina M, Avila-Ortiz G, García-Delgado R, Catena A, Galindo-Moreno P (2017) Inferior alveolar nerve trajectory, mental foramen location and incidence of mental nerve anterior loop. Med Oral Patol Oral Cir Bucal 22(5):e630–e635. https://doi.org/10.4317/medoral.21905

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  42. Yang XW, Zhang FF, Li YH, Wei B, Gong Y (2017) Characteristics of intra bony nerve canals in mandibular interforaminal region by using cone-beam computed tomography and a recommendation of safe zone for implant and bone harvesting. Clin Implant Dent Relat Res 19(3):530–538. https://doi.org/10.1111/cid.12474

    Article  PubMed  Google Scholar 

  43. do Nascimento EH, Dos Anjos Pontual ML, Dos Anjos Pontual A, da Cruz Perez DE, Figueiroa JN, Frazão MA, Ramos-Perez FM (2016) Assessment of the anterior loop of the mandibular canal: a study using cone-beam computed tomography. Imaging Cident 46(2):69–75. https://doi.org/10.5624/isd.2016.46.2.69

    Article  Google Scholar 

  44. Eren H, Orhan K, Bagis N, Nalcaci R, Misirli M, Hincal E (2016) Cone beam computed tomography evaluation of mandibular canal anterior loop morphology and volume in a group of Turkish patients. Biotechnol Biotechnol Equip 30(2):346–353. https://doi.org/10.1080/13102818.2015.1127181

    Article  Google Scholar 

  45. de Brito AC, Nejaim Y, de Freitas DQ, de Oliveira Santos CD (2016) Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal. Imaging Sci Dent 46(3):159–165. https://doi.org/10.5624/isd.2016.46.3.159

    Article  PubMed  PubMed Central  Google Scholar 

  46. Koivisto T, Chiona D, Milroy LL, McClanahan SB, Ahmad M, Bowles WR (2016) Mandibular canal location: cone-beam computed tomography examination. J Endod 42(7):1018–1021. https://doi.org/10.1016/j.joen.2016.03.004

    Article  PubMed  Google Scholar 

  47. Sahman H, Sisman Y (2016) Anterior loop of the inferior alveolar canal: a cone-beam computerized tomography study of 494 cases. J Oral Implant 42(4):333–336. https://doi.org/10.1563/aaid-joi-D-15-00038

    Article  Google Scholar 

  48. do Couto-Filho CE, de Moraes PH, Alonso MB, Haiter-Neto F, Olate S, de Albergaria-Barbosa JR (2015) Accuracy in the diagnosis of the mental nerve loop. A comparative study between panoramic radiography and cone beam computed tomography. Int J Morphol 33(1):327–332. https://doi.org/10.4067/s0717-95022015000100051

    Article  PubMed  Google Scholar 

  49. Vujanovic-Eskenazi A, Valero-James JM, Sánchez-Garcés MA, Gay-Escoda C (2015) A retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and cone beam computerized tomography. Med Oral Patol Oral Cir Bucal 20(2):e239–e245. https://doi.org/10.4317/medoral.20026

    Article  PubMed  Google Scholar 

  50. Panjnoush M, Rabiee ZS, Kheirandish Y (2016) Assessment of location and anatomical characteristics of mental foramen, anterior loop and mandibular incisive canal using cone beam computed tomography. J Dent (Tehran) 13(2):126–132

    Google Scholar 

  51. Lu CI, Won J, Al-Ardah A, Santana R, Rice D, Lozada J (2015) Assessment of the anterior loop of the mental nerve using cone beam computerized tomography scan. J Oral Implant 41(6):632–639. https://doi.org/10.1563/aaid-joi-D-13-00346

    Article  Google Scholar 

  52. von Arx T, Friedli M, Sendi P, Lozanoff S, Bornstein MM (2013) Location and dimensions of the mental foramen: a radiographic analysis by using cone-beam computed tomography. J Endod 39(12):1522–1528. https://doi.org/10.1016/j.joen.2013.07.033

    Article  Google Scholar 

  53. Parnia F, Moslehifard E, Hafezeqoran A, Mahboub F, Mojaver-Kahnamoui H (2012) Characteristics of anatomical landmarks in the mandibular inter. Characteristics of anatomical landmarks in the mandibular interforaminal region: a cone-beam computed tomography study. Med Oral Patol Oral Cir Bucal 17(3):e420–e425. https://doi.org/10.4317/medoral.17520

    Article  PubMed  Google Scholar 

  54. Kajan ZD, Salari A (2012) Presence and course of the mandibular incisive canal and presence of the anterior loop in cone beam computed tomography images of an Iranian population. Oral Radiol 28:55–61

    Article  Google Scholar 

  55. Bavitz JB, Harn SD, Hansen CA, Lang M (1993) An anatomical study of mental neurovascular bundle-implant relationships. Int J Oral Maxillofac Implants 8(5):563–567

    CAS  PubMed  Google Scholar 

  56. Santana RR, Lozada J, Kleinman A, Al-Ardah A, Herford A, Chen JW (2012) Accuracy of cone beam computerized tomography and a three-dimensional stereolithographic model in identifying the anterior loop of the mental nerve: a study on cadavers. J Oral Implantol 38(6):668–676. https://doi.org/10.1563/AAID-JOI-D-11-00130

    Article  PubMed  Google Scholar 

  57. Park HS, Lee YJ, Jeong SH, Kwon TG (2008) Density of the alveolar and basal bones of the maxilla and the mandible. Am J Orthod Dentofac Orthop 133(1):30–37. https://doi.org/10.1016/j.ajodo.2006.01.044

    Article  Google Scholar 

  58. Eren H, Gorgun S (2015) Evaluation of effective dose with twodimensional and three-dimensional dental imaging devices. J Contemp Dent 5(2):80–85. https://doi.org/10.5005/jp-journals-10031-1112

    Article  Google Scholar 

  59. De Vos W, Casselman J, Swennen GRJ (2009) Cone-beam computerized tomography (CBCT) ımaging of the oral and maxillofacial region: a systematic review of the literature. Int J Oral Maxillofac Surg 38(6):609–625. https://doi.org/10.1016/j.ijom.2009.02.028

    Article  PubMed  Google Scholar 

  60. Kung CY, Wang YM, Chan CP, Ju YR, Pan WL (2017) Evaluation of the mandibular lingual canal and anterior loop length to minimize complications associated with anterior mandibular surgeries: a cone-beam computed tomography study. J Oral Maxillofac Surg 75(10):2116.e1–2116.13. https://doi.org/10.1016/j.joms.2017.06.017

    Article  Google Scholar 

  61. Alhassani AA, AlGhamdi AS (2010) Inferior alveolar nerve injury in implant dentistry: diagnosis, causes, prevention, and management. J Oral Implantol 36(5):401–407. https://doi.org/10.1563/AAID-JOI-D-09-00059

    Article  PubMed  Google Scholar 

  62. Renton T (2010) Prevention of iatrogenic inferior alveolar nerve injuries in relation to dental procedures. Dent Update 37:350–352

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sunil Kumar Mishra.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

Not applied.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mishra, S.K., Nahar, R., Gaddale, R. et al. Identification of anterior loop in different populations to avoid nerve injury during surgical procedures—a systematic review and meta-analysis. Oral Maxillofac Surg 25, 159–174 (2021). https://doi.org/10.1007/s10006-020-00915-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10006-020-00915-x

Keywords

Navigation