Skip to main content

Advertisement

Log in

Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology

  • Original Article
  • Published:
Clinical Oral Investigations Aims and scope Submit manuscript

Abstract

Objectives

The aim of this study was to evaluate the mechanical analysis of different three-unit metal-free fixed dental prostheses (FDPs) produced by computer-aided design (CAD)/computer-aided manufacturing (CAM).

Materials and methods

A hundred stainless steel die models of a mandibular left first premolar and a mandibular left first molar were prepared. The specimens were divided into five CAD/CAM material groups (n = 20): Group ZIR, a cubic zirconia (DD cube ONE®); Group FRC, FRC resin material (Trinia); Group PEEK, a PEEK material (KERA® starPEEK); Group PEKK, a PEKK material (Pekkton® ivory); and Group COMP, a polymer composite material (BreCAM.HIPC). Compression test was applied to the specimens, and then the results were analyzed statistically using one-way ANOVA and Tukey’s tests. In addition, deformation analyses in FDPs were compared with finite element method (FEM). After the compression test, the damage to FDPs was evaluated with a scanning electron microscopy.

Results

Although ZIR (2461 ± 93.70 N) showed high fracture load values, FRC (1571 ± 35.96 N) material was found to be advantageous in terms of toughness. These were followed by PEEK (1398 ± 38.26 N), PEKK (1227 ± 44.25 N), and COMP (829 ± 32.33 N), respectively. A ductile fracture was observed in PEEK, PEKK, and FRC due to their elastic structures. The deformation properties examined by the FEM were found to be similar to the compression test.

Conclusions

CAD/CAM high-performance polymers and cubic zirconia material can be used in three-unit FDPs. In three-unit FDPs, the use of FRC material can be advantageous due to both biomechanics and lightness.

Clinical relevance

Metal-free CAD/CAM materials may offer new possibilities in three-unit FDPs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig.4
Fig.5
Fig.6

Similar content being viewed by others

Data availability

Not applicable.

References

  1. Preis V, Hahnel S, Behr M, Bein L, Rosentritt M (2017) In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater 33(4):427–433

    Article  Google Scholar 

  2. Lambert H, Durand JC, Jacquot B, Fages M (2017) Dental biomaterials for chairside CAD/CAM: State of the art. J Adv Prosthodont 9(6):486–495

    Article  Google Scholar 

  3. Denry I, Kelly JR (2014) Emerging ceramic-based materials for dentistry. J Dent Res 93(12):1235–1242

    Article  Google Scholar 

  4. Pereira GKR, Guilardi LF, Dapieve KS, Kleverlaan CJ, Rippe MP, Valandro LF (2018) Mechanical reliability, fatigue strength and survival analysis of new polycrystalline translucent zirconia ceramics for monolithic restorations. J Mech Behav Biomed Mater 85:57–65

    Article  Google Scholar 

  5. Yilmaz B, Batak B, Seghi RR (2019) Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Clin Implant Dent Relat Res 21(6):1132–1139

    Article  Google Scholar 

  6. Stawarczyk B, Keul C, Eichberger M, Figge D, Edelhoff D, Lümkemann N (2017) Three generations of zirconia: from veneered to monolithic. Part I Quintessence Int 48(5):369–380

    PubMed  Google Scholar 

  7. Alqurashi H, Khurshid Z, Syed AUY, Rashid Habib S, Rokaya D, Zafar MS (2020) Polyetherketoneketone (PEKK): AN emerging biomaterial for oral implants and dental prostheses. J Adv Res 28:87–95

    Article  Google Scholar 

  8. Erkmen E, Meriç G, Kurt A, Tunç Y, Eser A (2011) Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study. J Mech Behav Biomed Mater 4(1):107–116

    Article  Google Scholar 

  9. Najeeb S, Zafar MS, Khurshid Z, Siddiqui F (2016) Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 60(1):12–19

    Article  Google Scholar 

  10. Ahmed KE, Li KY, Murray CA (2017) Longevity of fiber-reinforced composite fixed partial dentures (FRC FPD)-Systematic review. J Dent 61:1–11

    Article  Google Scholar 

  11. Bergamo ETP, Bastos TMC, Lopes ACO, de Araujo Júnior ENS, Coelho PG, Benalcazar Jalkh EB, Zahoui A, Bonfante EA (2021) Physicochemical and mechanical characterization of a fiber-reinforced composite used as frameworks of implant-supported prostheses. Dent Mater 37(8):e443–e453

    Article  Google Scholar 

  12. Bonfante EA, Suzuki M, Carvalho RM, Hirata R, Lubelski W, Bonfante G, Pegoraro TA, Coelho PG (2015) Digitally produced fiber-reinforced composite substructures for three-unit implant-supported fixed dental prostheses. Int J Oral Maxillofac Implants 30(2):321–329

    Article  Google Scholar 

  13. Jovanović M, Živić M, Milosavljević M (2021) A potential application of materials based on a polymer and CAD/CAM composite resins in prosthetic dentistry. J Prosthodont Res 65(2):137–147

    Article  Google Scholar 

  14. Niem T, Youssef N, Wöstmann B (2019) Energy dissipation capacities of CAD-CAM restorative materials: a comparative evaluation of resilience and toughness. J Prosthet Dent 121(1):101–109

    Article  Google Scholar 

  15. Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR (2013) Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 101(7):1209–1216

    Article  Google Scholar 

  16. Amelya A, Kim JE, Woo CW, Otgonbold J, Lee KW (2019) Load-bearing capacity of posterior CAD/CAM implant-supported fixed partial dentures fabricated with different esthetic materials. Int J Prosthodont 32(2):201–204

    Article  Google Scholar 

  17. Rodríguez V, Tobar C, López-Suárez C, Peláez J, Suárez MJ (2021) Fracture load of metal, zirconia and polyetheretherketone posterior CAD-CAM milled fixed partial denture frameworks. Materials (Basel) 14(4):959

    Article  Google Scholar 

  18. Stawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR (2015) Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J 34(1):7–12

    Article  Google Scholar 

  19. Corbani K, Hardan L, Eid R, Skienhe H, Alharbi N, Ozcan M, Salameh Z (2021) Fracture resistance of three-unit fixed dental prostheses fabricated with milled and 3D printed composite-based materials. J Contemp Dent Pract 22(9):985–990

    Article  Google Scholar 

  20. Mayinger F, Pfefferle R, Reichert A, Stawarczyk B (2021) Impact of high-speed sintering of three-unit 3Y-TZP and 4Y-TZP fixed dental prostheses on fracture load with and without artificial aging. Int J Prosthodont 34(1):47–53

    Article  Google Scholar 

  21. López-Suárez C, Castillo-Oyagüe R, Rodríguez-Alonso V, Lynch CD, Suárez-García MJ (2018) Fracture load of metal-ceramic, monolithic, and bi-layered zirconia-based posterior fixed dental prostheses after thermo-mechanical cycling. J Dent 73:97–104

    Article  Google Scholar 

  22. Campaner LM, Silveira MPM, de Andrade GS, Borges ALS, Bottino MA, Dal Piva AMO, Lo Giudice R, Ausiello P, Tribst JPM (2021) Influence of polymeric restorative materials on the stress distribution in posterior fixed partial dentures: 3D finite element analysis. Polymers (Basel) 13(5):758

    Article  Google Scholar 

  23. Rayyan MM, Abdallah J, Segaan LG, Bonfante EA, Osman E (2020) Static and fatigue loading of veneered implant-supported fixed dental prostheses. J Prosthodont 29(8):679–685

    Article  Google Scholar 

  24. Partiyan A, Osman E, Rayyan MM, Aboushelib M, Ibrahim A, Jimbo R (2017) Fracture resistance of three-unit zirconia fixed partial denture with modified framework. Odontology 105(1):62–67

    Article  Google Scholar 

  25. Abad-Coronel C, Carrera E, MenaCórdova N, Fajardo JI, Aliaga P (2021) Comparative analysis of fracture resistance between CAD/CAM materials for interim fixed prosthesis. Materials (Basel) 14(24):7791

    Article  Google Scholar 

  26. Dayan SC, Geckili O (2021) The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput Methods Biomech Biomed Engin 24(14):1606–1617

    Article  Google Scholar 

  27. Zhang Y, Lawn BR (2018) Novel Zirconia Materials in Dentistry. J Dent Res 97(2):140–147

    Article  Google Scholar 

  28. Cevik P, Schimmel M, Yilmaz B (2022) New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies. Biomed Res Int 2(2022):3074182

    Google Scholar 

  29. Soares PM, Cadore-Rodrigues AC, Souto Borges AL, Valandro LF, Pereira GKR, Rippe MP (2021) Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes. J Mech Behav Biomed Mater 123:10476

    Article  Google Scholar 

  30. Gibbs CH, Mahan PE, Lundeen HC, Brehnan K, Walsh EK, Holbrook WB (1981) Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent 46:443–449

    Article  Google Scholar 

  31. Waltimo A, Kononen M (1993) A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res 101:171–175

    PubMed  Google Scholar 

  32. Hensel F, Koenig A, Doerfler HM, Fuchs F, Rosentritt M, Hahnel S (2021) CAD/CAM Resin-based composites for use in long-term temporary fixed dental prostheses. Polymers (Basel) 13(20):3469

    Article  Google Scholar 

  33. Zimmermann M, Ender A, Attin T, Mehl A (2020) Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology. Clin Oral Investig 24(2):1035–1042

    Article  Google Scholar 

  34. Rosentritt M, Behr M, Gebhard R, Handel G (2006) Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater 22(2):176–182

    Article  Google Scholar 

  35. Özcan M, Jonasch M (2018) Effect of cyclic fatigue tests on aging and their translational implications for survival of all-ceramic tooth-borne single crowns and fixed dental prostheses. J Prosthodont 27(4):364–375

    Article  Google Scholar 

  36. Wimmer T, Erdelt KJ, Eichberger M, Roos M, Edelhoff D, Stawarczyk B (2014) Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses. Dent Mater J 33(6):717–724

    Article  Google Scholar 

  37. Wimmer T, Ender A, Roos M, Stawarczyk B (2013) Fracture load of milled polymeric fixed dental prostheses as a function of connector cross-sectional areas. J Prosthet Dent 110(4):288–295

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the study conception and design. Material preparation, data collection, and analysis were performed by FD, EB, and MCB. Conceptualization, FD and EB; methodology, FD; formal analysis and investigation, FD and EB; writing-original draft preparation, FD and EB; writing-review and editing, FD, EB, and MCB; supervision, FD. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Fatih Demirci.

Ethics declarations

Consent to participate

Not applicable.

Informed consent

Not applicable.

Consent for publication

Not applicable.

Conflict of interest

The authors declare no competing interests.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Demirci, F., Bahce, E. & Baran, M.C. Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology. Clin Oral Invest 26, 5969–5978 (2022). https://doi.org/10.1007/s00784-022-04623-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00784-022-04623-6

Keywords

Navigation