Abstract
Objectives
The aim of this study was to evaluate the mechanical analysis of different three-unit metal-free fixed dental prostheses (FDPs) produced by computer-aided design (CAD)/computer-aided manufacturing (CAM).
Materials and methods
A hundred stainless steel die models of a mandibular left first premolar and a mandibular left first molar were prepared. The specimens were divided into five CAD/CAM material groups (n = 20): Group ZIR, a cubic zirconia (DD cube ONE®); Group FRC, FRC resin material (Trinia); Group PEEK, a PEEK material (KERA® starPEEK); Group PEKK, a PEKK material (Pekkton® ivory); and Group COMP, a polymer composite material (BreCAM.HIPC). Compression test was applied to the specimens, and then the results were analyzed statistically using one-way ANOVA and Tukey’s tests. In addition, deformation analyses in FDPs were compared with finite element method (FEM). After the compression test, the damage to FDPs was evaluated with a scanning electron microscopy.
Results
Although ZIR (2461 ± 93.70 N) showed high fracture load values, FRC (1571 ± 35.96 N) material was found to be advantageous in terms of toughness. These were followed by PEEK (1398 ± 38.26 N), PEKK (1227 ± 44.25 N), and COMP (829 ± 32.33 N), respectively. A ductile fracture was observed in PEEK, PEKK, and FRC due to their elastic structures. The deformation properties examined by the FEM were found to be similar to the compression test.
Conclusions
CAD/CAM high-performance polymers and cubic zirconia material can be used in three-unit FDPs. In three-unit FDPs, the use of FRC material can be advantageous due to both biomechanics and lightness.
Clinical relevance
Metal-free CAD/CAM materials may offer new possibilities in three-unit FDPs.
Similar content being viewed by others
Data availability
Not applicable.
References
Preis V, Hahnel S, Behr M, Bein L, Rosentritt M (2017) In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns. Dent Mater 33(4):427–433
Lambert H, Durand JC, Jacquot B, Fages M (2017) Dental biomaterials for chairside CAD/CAM: State of the art. J Adv Prosthodont 9(6):486–495
Denry I, Kelly JR (2014) Emerging ceramic-based materials for dentistry. J Dent Res 93(12):1235–1242
Pereira GKR, Guilardi LF, Dapieve KS, Kleverlaan CJ, Rippe MP, Valandro LF (2018) Mechanical reliability, fatigue strength and survival analysis of new polycrystalline translucent zirconia ceramics for monolithic restorations. J Mech Behav Biomed Mater 85:57–65
Yilmaz B, Batak B, Seghi RR (2019) Failure analysis of high performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses. Clin Implant Dent Relat Res 21(6):1132–1139
Stawarczyk B, Keul C, Eichberger M, Figge D, Edelhoff D, Lümkemann N (2017) Three generations of zirconia: from veneered to monolithic. Part I Quintessence Int 48(5):369–380
Alqurashi H, Khurshid Z, Syed AUY, Rashid Habib S, Rokaya D, Zafar MS (2020) Polyetherketoneketone (PEKK): AN emerging biomaterial for oral implants and dental prostheses. J Adv Res 28:87–95
Erkmen E, Meriç G, Kurt A, Tunç Y, Eser A (2011) Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study. J Mech Behav Biomed Mater 4(1):107–116
Najeeb S, Zafar MS, Khurshid Z, Siddiqui F (2016) Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 60(1):12–19
Ahmed KE, Li KY, Murray CA (2017) Longevity of fiber-reinforced composite fixed partial dentures (FRC FPD)-Systematic review. J Dent 61:1–11
Bergamo ETP, Bastos TMC, Lopes ACO, de Araujo Júnior ENS, Coelho PG, Benalcazar Jalkh EB, Zahoui A, Bonfante EA (2021) Physicochemical and mechanical characterization of a fiber-reinforced composite used as frameworks of implant-supported prostheses. Dent Mater 37(8):e443–e453
Bonfante EA, Suzuki M, Carvalho RM, Hirata R, Lubelski W, Bonfante G, Pegoraro TA, Coelho PG (2015) Digitally produced fiber-reinforced composite substructures for three-unit implant-supported fixed dental prostheses. Int J Oral Maxillofac Implants 30(2):321–329
Jovanović M, Živić M, Milosavljević M (2021) A potential application of materials based on a polymer and CAD/CAM composite resins in prosthetic dentistry. J Prosthodont Res 65(2):137–147
Niem T, Youssef N, Wöstmann B (2019) Energy dissipation capacities of CAD-CAM restorative materials: a comparative evaluation of resilience and toughness. J Prosthet Dent 121(1):101–109
Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR (2013) Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 101(7):1209–1216
Amelya A, Kim JE, Woo CW, Otgonbold J, Lee KW (2019) Load-bearing capacity of posterior CAD/CAM implant-supported fixed partial dentures fabricated with different esthetic materials. Int J Prosthodont 32(2):201–204
Rodríguez V, Tobar C, López-Suárez C, Peláez J, Suárez MJ (2021) Fracture load of metal, zirconia and polyetheretherketone posterior CAD-CAM milled fixed partial denture frameworks. Materials (Basel) 14(4):959
Stawarczyk B, Eichberger M, Uhrenbacher J, Wimmer T, Edelhoff D, Schmidlin PR (2015) Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J 34(1):7–12
Corbani K, Hardan L, Eid R, Skienhe H, Alharbi N, Ozcan M, Salameh Z (2021) Fracture resistance of three-unit fixed dental prostheses fabricated with milled and 3D printed composite-based materials. J Contemp Dent Pract 22(9):985–990
Mayinger F, Pfefferle R, Reichert A, Stawarczyk B (2021) Impact of high-speed sintering of three-unit 3Y-TZP and 4Y-TZP fixed dental prostheses on fracture load with and without artificial aging. Int J Prosthodont 34(1):47–53
López-Suárez C, Castillo-Oyagüe R, Rodríguez-Alonso V, Lynch CD, Suárez-García MJ (2018) Fracture load of metal-ceramic, monolithic, and bi-layered zirconia-based posterior fixed dental prostheses after thermo-mechanical cycling. J Dent 73:97–104
Campaner LM, Silveira MPM, de Andrade GS, Borges ALS, Bottino MA, Dal Piva AMO, Lo Giudice R, Ausiello P, Tribst JPM (2021) Influence of polymeric restorative materials on the stress distribution in posterior fixed partial dentures: 3D finite element analysis. Polymers (Basel) 13(5):758
Rayyan MM, Abdallah J, Segaan LG, Bonfante EA, Osman E (2020) Static and fatigue loading of veneered implant-supported fixed dental prostheses. J Prosthodont 29(8):679–685
Partiyan A, Osman E, Rayyan MM, Aboushelib M, Ibrahim A, Jimbo R (2017) Fracture resistance of three-unit zirconia fixed partial denture with modified framework. Odontology 105(1):62–67
Abad-Coronel C, Carrera E, MenaCórdova N, Fajardo JI, Aliaga P (2021) Comparative analysis of fracture resistance between CAD/CAM materials for interim fixed prosthesis. Materials (Basel) 14(24):7791
Dayan SC, Geckili O (2021) The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput Methods Biomech Biomed Engin 24(14):1606–1617
Zhang Y, Lawn BR (2018) Novel Zirconia Materials in Dentistry. J Dent Res 97(2):140–147
Cevik P, Schimmel M, Yilmaz B (2022) New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies. Biomed Res Int 2(2022):3074182
Soares PM, Cadore-Rodrigues AC, Souto Borges AL, Valandro LF, Pereira GKR, Rippe MP (2021) Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes. J Mech Behav Biomed Mater 123:10476
Gibbs CH, Mahan PE, Lundeen HC, Brehnan K, Walsh EK, Holbrook WB (1981) Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent 46:443–449
Waltimo A, Kononen M (1993) A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res 101:171–175
Hensel F, Koenig A, Doerfler HM, Fuchs F, Rosentritt M, Hahnel S (2021) CAD/CAM Resin-based composites for use in long-term temporary fixed dental prostheses. Polymers (Basel) 13(20):3469
Zimmermann M, Ender A, Attin T, Mehl A (2020) Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology. Clin Oral Investig 24(2):1035–1042
Rosentritt M, Behr M, Gebhard R, Handel G (2006) Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater 22(2):176–182
Özcan M, Jonasch M (2018) Effect of cyclic fatigue tests on aging and their translational implications for survival of all-ceramic tooth-borne single crowns and fixed dental prostheses. J Prosthodont 27(4):364–375
Wimmer T, Erdelt KJ, Eichberger M, Roos M, Edelhoff D, Stawarczyk B (2014) Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses. Dent Mater J 33(6):717–724
Wimmer T, Ender A, Roos M, Stawarczyk B (2013) Fracture load of milled polymeric fixed dental prostheses as a function of connector cross-sectional areas. J Prosthet Dent 110(4):288–295
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. Material preparation, data collection, and analysis were performed by FD, EB, and MCB. Conceptualization, FD and EB; methodology, FD; formal analysis and investigation, FD and EB; writing-original draft preparation, FD and EB; writing-review and editing, FD, EB, and MCB; supervision, FD. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Consent to participate
Not applicable.
Informed consent
Not applicable.
Consent for publication
Not applicable.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Demirci, F., Bahce, E. & Baran, M.C. Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology. Clin Oral Invest 26, 5969–5978 (2022). https://doi.org/10.1007/s00784-022-04623-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00784-022-04623-6