Abstract
Background
We investigated the effect of low-intensity ultrasound on bone healing in bioabsorbable self-reinforced poly-l-lactic acid (SR-PLLA) screw-fixed lateral malleolar fractures. The study design was prospective, randomized, double-blind, and placebo-controlled.
Methods
A total of 22 fractures were fixed with one SR-PLLA screw. All the patients were instructed to use an ultrasound device 20 min daily for 42 days without knowing whether it was active or inactive. Eleven patients had active and eleven sham ultrasound devices. The causes of error during treatment with head module placement and attachment to the convex surface of the lateral distal fibula were minimized by careful targeting and using coupling gel. Radiological fracture healing was assessed by radiographs and multidetector computed tomography (CT) scans in a blinded manner by a radiologist and orthopedic surgeons.
Results
The overall compliance to the daily ultrasound treatments was good. All wounds healed uneventfully, and no foreign body reactions were observed. No difference was observed between the groups regarding either fracture line visualization or callus formation assessed by plain radiographs. In the CT images at 9 weeks, the share of the endosteal united fracture line compared to the non-united fracture line was slightly higher in the active ultrasound device group than in the sham ultrasound device group, but the difference was not statistically significant.
Conclusion
The study indicates that the biocompatibility of ultrasound therapy and bioabsorbable SR-PLLA screw fixation is good. There was no obvious effect of low-intensity ultrasound on lateral malleolar fracture healing. However, the relatively small number of patients must be kept in mind when interpreting our results. It is also important to limit any conclusions based on the present study to malleolar fractures fixed with the SR-PLLA screw.
Similar content being viewed by others
References
P Rokkanen O Böstman S Vainionpä K Vihtonen P Törmälä J Laiho et al. (1985) ArticleTitleBiodegradable implants in fracture fixation: early results of treatment of fractures of the ankle Lancet 1 1422–4 10.1016/S0140-6736(85)91847-1 Occurrence Handle10.1016/S0140-6736(85)91847-1 Occurrence Handle1:STN:280:DyaL2M3jvFektg%3D%3D Occurrence Handle2861365
RW Bucholz S Henry MB Henley (1994) ArticleTitleFixation with bioabsorbable screws for the treatment of fractures of the ankle J Bone Joint Surg Am 76 319–24 Occurrence Handle1:STN:280:DyaK2c7ntFymsg%3D%3D Occurrence Handle8126036
EK Partio O Böstman E Hirvensalo S Vainionpä K Vihtonen H Pätiälä et al. (1992) ArticleTitleSelf-reinforced absorbable screws in the fixation of displaced ankle fractures: a prospective clinical study of 152 patients J Orthop Trauma 6 209–15 Occurrence Handle10.1097/00005131-199206000-00013 Occurrence Handle1:STN:280:DyaK383ptFOrtQ%3D%3D Occurrence Handle1318361
Y Azuma M Ito Y Harada H Takagi T Ohta S Jingushi (2001) ArticleTitleLow-intensity pulsed ultrasound accelerates rat femoral fracture healing by acting on the various cellular reactions in the fracture callus J Bone Miner Res 16 671–80 Occurrence Handle10.1359/jbmr.2001.16.4.671 Occurrence Handle1:STN:280:DC%2BD3MvlvFKrug%3D%3D Occurrence Handle11315994
AA Pilla MA Mont PR Nasser SA Khan M Figueiredo JJ Kaufman et al. (1990) ArticleTitleNon-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit J Orthop Trauma 4 246–53 Occurrence Handle10.1097/00005131-199004030-00002 Occurrence Handle1:STN:280:DyaK3M%2FjvVCrsg%3D%3D Occurrence Handle2231120
SJ Wang DG Lewallen ME Bolander EY Chao DM Ilstrup JF Greenleaf (1994) ArticleTitleLow-intensity ultrasound treatment increases strength in a rat femoral fracture model J Orthop Res 12 40–7 10.1002/jor.1100120106 Occurrence Handle10.1002/jor.1100120106 Occurrence Handle1:STN:280:DyaK2c7lslOiuw%3D%3D Occurrence Handle8113941
SD Cook JP Ryaby J McCabe JJ Frey JD Heckman TK Kristiansen (1997) ArticleTitleAcceleration of tibia and distal radius fracture healing in patients who smoke Clin Orthop 337 198–207 Occurrence Handle10.1097/00003086-199704000-00022 Occurrence Handle9137191
JD Heckman JP Ryaby J McCabe JJ Frey RF Kilcoyne (1994) ArticleTitleAcceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound J Bone Joint Surg Am 76 26–34 Occurrence Handle1:STN:280:DyaK2c7hslGhug%3D%3D Occurrence Handle8288661
TK Kristiansen JP Ryaby J McCabe JJ Frey LR Roe (1997) ArticleTitleAccelerated healing of distal radial fractures with the use of specific, low-intensity ultrasound: a multicenter, prospective, randomized, double-blind, placebo-controlled study J Bone Joint Surg Am 79 961–73 Occurrence Handle1:STN:280:DyaK2sznvVWqsw%3D%3D Occurrence Handle9234872
A Emami M Petrén-Mallmin S Larsson (1999) ArticleTitleNo effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures J Orthop Trauma 13 252–7 10.1097/00005131-199905000-00005 Occurrence Handle10.1097/00005131-199905000-00005 Occurrence Handle1:STN:280:DyaK1M3ntFOkug%3D%3D Occurrence Handle10342350
M Hadjiargyrou K McLeod JP Ryaby C Rubin (1998) ArticleTitleEnhancement of fracture healing by low intensity ultrasound Clin Orthop 355 S216–29 10.1097/00003086-199810001-00022 Occurrence Handle9917641
JS Sun RC Hong WH Chang LT Chen FH Lin HC Liu (2001) ArticleTitleIn vitro effects of low-intensity ultrasound stimulation on the bone cells J Biomed Mater Res 57 449–56 10.1002/1097-4636(20011205)57:3<449::AID-JBM1188>3.0.CO;2-0 Occurrence Handle10.1002/1097-4636(20011205)57:3<449::AID-JBM1188>3.0.CO;2-0 Occurrence Handle1:CAS:528:DC%2BD3MXntFChur8%3D Occurrence Handle11523040
KH Yang J Parvizi SJ Wang DG Lewallen RR Kinnick JF Greenleaf et al. (1996) ArticleTitleExposure to low-intensity ultrasound increases aggrecan gene expression in a rat femur fracture model J Orthop Res 14 802–9 10.1002/jor.1100140518 Occurrence Handle10.1002/jor.1100140518 Occurrence Handle1:STN:280:DyaK2s%2FkvFSntw%3D%3D Occurrence Handle8893775
JO Hollinger GC Battistone (1986) ArticleTitleBiodegradable bone repair materials: synthetic polymers and ceramics Clin Orthop 207 290–305 Occurrence Handle1:CAS:528:DyaL28XkvVCqur0%3D Occurrence Handle3522015
DK Gilding (1981) Biodegradable polymers DF Williams (Eds) Biocompatibility of clinical implant materials. Vol 2 CRC Press Boca Raton 209–32
T Pohjonen P Helevirta P Törmälä K Koskikare H Pätiälä P Rokkanen (1997) ArticleTitleStrength retention of self-reinforced poly-l-lactide screws: a comparison of compression moulded and machine cut screws J Mater Sci Mater Med 8 311–20 10.1023/A:1018516529591 Occurrence Handle10.1023/A:1018516529591 Occurrence Handle1:CAS:528:DyaK2sXjtF2is7s%3D Occurrence Handle15348754
PU Rokkanen O Böstman E Hirvensalo EA Mäkelä EK Partio H Pätiälä et al. (2000) ArticleTitleBioabsorbable fixation in orthopaedic surgery and traumatology Biomaterials 21 2607–13 10.1016/S0142-9612(00)00128-9 Occurrence Handle10.1016/S0142-9612(00)00128-9 Occurrence Handle1:CAS:528:DC%2BD3cXmvFylsLo%3D Occurrence Handle11071610
L Handolin T Pohjonen EK Partio I Arnala P Törmälä P Rokkanen (2002) ArticleTitleThe effects of low-intensity pulsed ultrasound on bioabsorbable self-reinforced poly-l-lactide screws Biomaterials 23 2733–6 10.1016/S0142-9612(02)00006-6 Occurrence Handle10.1016/S0142-9612(02)00006-6 Occurrence Handle1:CAS:528:DC%2BD38XjsVSqsbo%3D Occurrence Handle12059023
M Grigoryan JA Lynch AL Fierlinger A Guermazi B Fan DB MacLean et al. (2003) ArticleTitleQuantitative and qualitative assessment of closed fracture healing using computed tomography and conventional radiography Acad Radiol 10 1267–73 10.1016/S1076-6332(03)00467-7 Occurrence Handle10.1016/S1076-6332(03)00467-7 Occurrence Handle14626301
Author information
Authors and Affiliations
About this article
Cite this article
Handolin, L., Kiljunen, V., Arnala, I. et al. Effect of ultrasound therapy on bone healing of lateral malleolar fractures of the ankle joint fixed with bioabsorbable screws. J Orthop Sci 10, 391–395 (2005). https://doi.org/10.1007/s00776-005-0901-0
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s00776-005-0901-0