Assessing Safety and Transceive Performance of a Body Coil Combined with a Volumetric Wireless Coil for Wrist MRI at 3 T

  • Original Paper
  • Published:
Applied Magnetic Resonance Aims and scope Submit manuscript

Abstract

The concept of a volumetric wireless coil electromagnetically coupled to a body coil (BC) to improve the quality and radiofrequency (RF) safety of wrist MRI at 1.5 T was recently proposed and confirmed via in vivo studies. Here, we demonstrate, for the first time, that the same concept can be applied at 3 T, where the RF safety issue is more critical. Our work includes a detailed analysis of the wireless coil robustness to the possible breakages of coil elements and its imperfect positioning inside the BC. The wireless coil design is based on a periodic array of coupled split-loop resonators. The cases of wireless coil breakage and inaccurate positioning were considered in terms of influence on RF safety via electromagnetic simulations with a human voxel model. In vivo experiments were also performed to evaluate the transmit efficiency and uniformity of the B1+-field. Numerical simulations demonstrated that the wireless coil provides a 4.1-fold increase in the local RF safety and almost a sevenfold increase in the global RF safety in comparison with the case of the same BC used alone. Minor breakages and positioning errors only slightly affect the transmit efficiency and the RF safety, confirming the wireless coil robustness. The wireless coil was shown to be feasible for wrist imaging at 3 T. A significant improvement of the RF safety may be useful in studies with implants and in the case when high-performance pulse sequences are required for improving the image quality.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. A. Barile et al., Radiol. Clin. North Am. (2017). https://doi.org/10.1016/j.rcl.2017.04.006

    Article  Google Scholar 

  2. M. Østergaard, M. Boesen, Radiol Med. (2019). https://doi.org/10.1007/s11547-019-01014-y

    Article  Google Scholar 

  3. D. Glinatsi et al., J. Rheumatol. (2015). https://doi.org/10.3899/jrheum.141009

    Article  Google Scholar 

  4. C.G. Peterfy et al., Arthritis Res. Ther. (2013). https://doi.org/10.1186/ar4202

    Article  Google Scholar 

  5. A.V. Shchelokova et al., Magn. Reson. Med. (2018). https://doi.org/10.1002/mrm.27140

    Article  Google Scholar 

  6. E.A. Brui et al., J. Magn. Reson. (2022). https://doi.org/10.1016/j.jmr.2022.107209

    Article  Google Scholar 

  7. S.I. Maslovski et al., Prog. Electromagn. Res. (2005). https://doi.org/10.2528/PIER04101101

    Article  Google Scholar 

  8. E.A. Brui et al., MAGMA (2021). https://doi.org/10.1007/s10334-021-00937-w

    Article  Google Scholar 

  9. G. Wieners et al., Eur. Radiol. (2007). https://doi.org/10.1007/s00330-006-0539-0

    Article  Google Scholar 

  10. M.L. Anderson et al., J. Hand Surg. (2008). https://doi.org/10.1016/j.jhsa.2008.02.028

    Article  Google Scholar 

  11. C.K. Chou et al., Bioelectromagnetics (1996). https://doi.org/10.1002/(sici)1521-186x(1996)17:3%3C195::aid-bem5%3E3.0.co;2-z

    Article  Google Scholar 

  12. R. Stollberger et al., Magn Reson Med. (1997). https://doi.org/10.1002/mrm.1910350217

    Article  Google Scholar 

  13. C.H. Cunningham et al., Magn Reson Med. (2006). https://doi.org/10.1002/mrm.20896

    Article  Google Scholar 

  14. D. Kim et al., Magn. Reson. Med. (2009). https://doi.org/10.1002/2Fmrm.22140

    Article  Google Scholar 

  15. F. Del Grande et al., JA Radiogr. (2014). https://doi.org/10.1148/rg.341135130

    Article  Google Scholar 

Download references

Acknowledgements

The part of the research devoted to the wireless coil design and experimental studies was supported by the Ministry of Education and Science of the Russian Federation (075-15-2021-592). The part of the work related to the RF safety assessment of the wireless coil was carried out with the support of a grant from the President of the Russian Federation for scientific school HШ-2359.2022.4.

Funding

Ministry of Education and Science of the Russian Federation (075-15-2021-592); Grant from the President of the Russian Federation for scientific school HШ-2359.2022.4.

Author information

Authors and Affiliations

Authors

Contributions

AN performed the simulations; PT built a prototype; EB and AN performed the experiments; AN drafted the manuscript; PT, AV and EB reviewed the manuscript.

Corresponding author

Correspondence to Aleksei Nasonov.

Ethics declarations

Conflict of Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nasonov, A., Tikhonov, P., Shchelokova, A. et al. Assessing Safety and Transceive Performance of a Body Coil Combined with a Volumetric Wireless Coil for Wrist MRI at 3 T. Appl Magn Reson 53, 1597–1607 (2022). https://doi.org/10.1007/s00723-022-01502-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00723-022-01502-x

Navigation