Abstract

In this paper, we considered the use of a wireless coil designed from a routine surface coil in 1H/19F magnetic resonance imaging (MRI). When it was positioned within a transmit/receive volume coil, a strong inductive coupling was appeared. A high sensitivity and undistorted B1 field distribution formed from the location of the wireless coil were observed only in a co-rotating current mode (high-frequency mode). For this matching quality, MR images of phantoms and mouse brain were acquired. The use of inductively coupled coil system has allowed to obtain 1H/19F MR images with the greater SNR directly from the location of the wireless coil in more than 6–7 times in comparison with using only transmit/receive volume coil. Compared to use only transmit/receive surface coil, the 1H NMR signal acquired directly from the wireless coil location was more than three times higher. At the same time, the use of an active decoupling between transmit and receive coils gives better results than using a strong inductively coupled coil system, but a reduction of the SNR near the wireless coil location is less no more than 20%. The results present the possibilities of using the wireless coil in conventional 1H/19F MRI studies and can be useful for implantable coil applications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. L. Ciobanu, C.H. Pennington, Solid State Nucl. Magn. Reson. 25(1–3), 138–141 (2004)

    Article  Google Scholar 

  2. E.T. Ahrens, J. Zhong, NMR Biomed. 26(7), 860–871 (2013)

    Article  Google Scholar 

  3. M.S. Fox, J.M. Gaudet, P.J. Foster, Magn. Reson. Insights 8(1), 53–67 (2015)

    Google Scholar 

  4. E.D. Wirth 3rd, T.H. Mareci, B.L. Beck, J.R. Fitzsimmons, P.J. Reier, Magn. Reson. Med. 30(5), 626–633 (1993)

    Article  Google Scholar 

  5. S.B. Bulumulla, E. Fiveland, K.J. Park, T.K. Foo, C.J. Hardy, Magn. Reson. Imaging 33(3), 351–357 (2015)

    Article  Google Scholar 

  6. M. Bilgen, I. Elshafiey, P.A. Narayana, Magn. Reson. Med. 46(6), 1250–1253 (2001)

    Article  Google Scholar 

  7. J.-C. Ginefri, A. Rubin, M. Tatoulian, M. Woytasik, F. Boumezbeur, B. Djemaï, M. Poirier-Quinot, F. Lethimonnier, L. Darrasse, E. Dufour-Gergam, J. Magn. Reson. 224, 61–70 (2012)

    Article  ADS  Google Scholar 

  8. W. Froncisz, A. Jesmanowicz, J.S. Hyde, J. Magn. Reson. 66(1), 135–143 (1986)

    ADS  Google Scholar 

  9. N.V. Anisimov, M.V. Gulyaev, D.V. Volkov, O.S. Pavlova, YuA Pirogov, J. Radio Electron. 11, 1–11 (2016)

    Google Scholar 

  10. H. Hirayama, in Equivalent Circuit and Calculation of its Parameters of Magnetic-Coupled-Resonant Wireless Power Transfer. Wireless Power Transfer—Principles and Engineering explorations, ed. by K.Y. Kim (InTech, Rijeka, 2012). ISBN 978-953-307-874-8

    Google Scholar 

  11. E.I. Maevsky, L.L. Gervits, Chim. Oggi 26(3), 34–37 (2008)

    Google Scholar 

  12. C.A. Schneider, W.S. Rasband, K.W. Eliceiri, Nat. Methods 9(7), 671–675 (2012)

    Article  Google Scholar 

  13. O. Dietrich, J.G. Raya, S.B. Reeder, M.F. Reiser, S.O. Schoenber, J. Magn. Reson. Imaging 26(2), 375–385 (2007)

    Article  Google Scholar 

  14. C. Jacoby, S. Temme, F. Mayenfels, N. Benoit, M.P. Krafft, R. Schubert, J. Schrader, U. Flögel, NMR Biomed. 27(3), 261–271 (2014)

    Article  Google Scholar 

  15. W. Froncisz, A. Jesmanowicz, J.B. Kneeland, J.S. Hyde, Magn. Reson. Med. 3(4), 590–603 (1986)

    Article  Google Scholar 

  16. N.A. Volland, T.H. Mareci, I. Constantinidis, N.E. Simpson, Magn. Reson. Med. 63(4), 998–1006 (2010)

    Article  Google Scholar 

  17. G. Helms, H. Dathe, N. Weiskopf, P. Dechent, Magn. Reson. Med. 66(3), 669–677 (2011)

    Article  Google Scholar 

Download references

Acknowledgements

This study was carried out at the Moscow State University on the equipment of the Collective Using Center “Biospectrotomography” and supported by the Russian Science Foundation Grant no. 17-79-10448.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mikhail V. Gulyaev.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gulyaev, M.V., Pavlova, O.S., Volkov, D.V. et al. The Use of Strong Inductively Coupled Wireless Surface Coil and Transmit/Receive Volume Coil for 1H/19F MRI. Appl Magn Reson 50, 403–413 (2019). https://doi.org/10.1007/s00723-018-1086-y

Download citation

  • Received:

  • Revised:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00723-018-1086-y

Navigation