Abstract
A simple and effective method for validation of antibody labelling procedure as well as for optimal conjugate dilution assessment based on electrochemical detection is presented. Enzyme alkaline phosphatase and core-shell CdSe/ZnS quantum dots are used as sensitive tag exploitable as detection tool of antibody-antigen complex in magnetic microbead-based immunoassays. Square-wave voltammetry for detection of the electroactive product that is induced by conversion of appropriate substrate by alkaline phosphatase and square-wave anodic-stripping voltammetry for signal of Cd in case of quantum dots, respectively, was elected. Anti-Apo E IgG antibodies were selected as model molecules for method optimizations.
Graphical abstract
Similar content being viewed by others
References
Zhu GN, Jin MJ, Gui WJ, Guo YR, Jin RY, Wang CM, Liang CZ, Liu YH, Wang ST (2008) Food Chem 107:1737
Xue-Mei L, Xiao-Yan Ym Shu-Sheng Z (2008) Trends. Anal Chem 27:543
Wang R, Chen X, Ma J, Ma Z (2013) Sens Actuators B 176:1044
Rusling JF, Sotzing G, Papadimitrakopoulosa F (2009) Bioelectrochemistry 76:189
Abuknesha RA, Luk CY, Griffith HHM, Maragkou A, Iakovaki D (2005) J Immunol Methods 306:211
Cappione A, Mabuchi M, Briggs D, Nadler T (2015) J Immunol Methods 419:48
Kuramitz H (2009) Anal Bioanal Chem 394:61
Hermanson GT (ed) (2008) Bioconjugate techniques, 2nd edn. Academic Press, New York, p 213
Čadková M, Metelka R, Holubová L, Horák D, Dvořáková V, Bílková Z, Korecká L (2015) Anal Biochem 484:4
Hein CD, Liu X-M, Wang D (2008) Pharm Res 25:2216
Cleland WW, Hengge AC (2006) Chem Rev 106:3252
Djellouli VN, Rochelet-Dequaire M, Limoges B, Druet M, Brossier P (2007) Biosens Bioelectron 22:2906
Holzinger M, Le Goff A, Cosiner S (2014) Front Chem. doi:10.3389/fchem.2014.00063
Sun H, Wang M, Wang J, Tian M, Wang H, Sun Z, Huang P (2015) J Trace Elem Med Biol 30:37
Yu C, Kim G-B, Clark PM, Zubkov L, Papazoglou ES, Noh M (2015) Sens Actuator B-Chem 209:722
Zhu X, Duan D, Publicover NG (2010) Analyst 135:381
Pemberton RM, Hart JP, Stoddard P, Foulkes JA (1999) Biosens Bioelectron 14:495
Čadková M, Dvořáková V, Metelka R, Bílkková Z, Korcká Z (2015) Electrochem Commun 59:1
http://www.thermofisher.com/order/catalog/product/S10450?ICID=search-product. Accessed 05 Sep 2015
http://www.innovabiosciences.com/antibody-labeling-kits/enzymes/lightning-link-alkaline-phosphatase-ap.html. Accessed 05 Sep 2015
Acknowledgments
Support of the Czech Science Foundation Grant No. 15-16549S and University of Pardubice, Faculty of Chemical Technology (Project No. SGFChT07/2015) is gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Additional information
M. Čadková and V. Dvořáková contributed equally to this work.
Rights and permissions
About this article
Cite this article
Čadková, M., Dvořáková, V., Metelka, R. et al. Verification of antibody labelling efficiency as an important step in ELISA/QLISA development. Monatsh Chem 147, 69–73 (2016). https://doi.org/10.1007/s00706-015-1598-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00706-015-1598-1