Abstract
Background
Transarticular C1–C2 screw fixation, first described by Magerl, is a widely accepted used technique for C1–C2 instability with a good biomechanical stability and fusion rate.
Method
We present a 69-year-old woman, who was diagnosed with a C2 Odontoid fracture type III and primarily treated with conservative treatment and collar. During first 2 weeks of follow-up, the patient developed cervical pain associated with C1–C2 instability. A minimally invasive posterior C1–C2 transarticular screw instrumentation with a percutaneus approach was performed.
Results and conclusion
Minimally invasive approach with tubular transmuscular approach for C1–C2 transarticular screws instrumentation is safe and effective for C1–C2 instability.
Similar content being viewed by others
References
ElSaghir H, Boehm H, Greiner-Perth R (2005) Mini-open approach combined with percutaneous transarticular screw fixation for C1-C2 fusion. Neurosurg Rev 28:59–63. https://doi.org/10.1007/s10143-004-0358-1
Goel A, Gupta S (1999) Vertebral artery injury with transarticular screws. J Neurosurg 90:376–377. https://doi.org/10.3171/jns.1999.90.2.0376a
Lvov I, Grin A, Kordonskiy A, Sytnik A, Smirnov V, Khushnazarov U, Krylov V (2019) Minimally invasive posterior transarticular stand-alone screw instrumentation of C1-C2 using a transmuscular approach: description of technique, results and comparison with posterior midline exposure. World Neurosurg 128:e796–e805. https://doi.org/10.1016/j.wneu.2019.04.259
Mandel IM, Kambach BJ, Petersilge CA, Johnstone B, Yoo JU (2000) Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws. Spine (Phila Pa 1976) 25:1542–1547. https://doi.org/10.1097/00007632-200006150-00014
Moon BJ, Choi KH, Shin DA, Yi S, Kim KN, Yoon DH, Ha Y (2018) Anatomical variations of vertebral artery and C2 isthmus in atlanto-axial fusion: consecutive surgical 100 cases. J Clin Neurosci 53:147–152. https://doi.org/10.1016/j.jocn.2018.04.058
Neo M, Fujibayashi S, Miyata M, Takemoto M, Nakamura T (2008) Vertebral artery injury during cervical spine surgery: a survey of more than 5600 operations. Spine (Phila Pa 1976) 33:779–785. https://doi.org/10.1097/BRS.0b013e31816957a7
Paramore CG, Dickman CA, Sonntag VK (1996) The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 85:221–224. https://doi.org/10.3171/jns.1996.85.2.0221
Yamazaki M, Okawa A, Furuya T, Sakuma T, Takahashi H, Kato K, Fujiyoshi T, Mannoji C, Takahashi K, Koda M (2012) Anomalous vertebral arteries in the extra- and intraosseous regions of the craniovertebral junction visualized by 3-dimensional computed tomographic angiography: analysis of 100 consecutive surgical cases and review of the literature. Spine (Phila Pa 1976) 37:E1389–E1397. https://doi.org/10.1097/BRS.0b013e31826a0c9f
Yoshida M, Neo M, Fujibayashi S, Nakamura T (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine (Phila Pa 1976) 31:E513–E517. https://doi.org/10.1097/01.brs.0000224516.29747.52
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Informed consent was obtained from all individual participants included in the study.
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
This article is part of the Topical Collection on Spine trauma
Electronic supplementary material
(MP4 23,308 kb)
Rights and permissions
About this article
Cite this article
Dimitriou, J., Garvayo, M. & Coll, J.B. Minimally invasive posterior percutaneous transarticular C1–C2 screws: how I do it. Acta Neurochir 162, 2047–2050 (2020). https://doi.org/10.1007/s00701-020-04478-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00701-020-04478-4