Background

The white-collar sign (WCS) is represented by the formation of neointimal tissue at the level of the aneurysm neck as the successful outcome on follow-up angiography after coil embolization. WCS has been reported only in aneurysms treated with Matrix® coils. This is the first study to report WCS emergence in aneurysms treated with bare platinum coils, and potential factors associated with WCS emergence were evaluated.

Method

Total 130 unruptured (female: male ratio, 100: 30; mean age, 60 years) cerebral aneurysms were treated with coil embolization. Embolization status was assessed immediately and 1 year after treatment, and emergence of WCS in follow-up angiography was assessed. We evaluated the association between WCS emergence and aneurysm location, dome diameter, neck diameter, dome-neck ratio, and type of coil used (bare platinum or bioactive).

Results

WCS appeared in nine aneurysms (6.9 %), of which six were treated only with bare platinum coils. Neck diameter was significantly smaller in the WCS-positive group than in the WCS-negative group. The proportion of aneurysms treated with bioactive coils was not significantly different between the groups. Immediate embolization status in the WCS-positive group tended to be slightly better than that in the WCS-negative group. No aneurysmal morphological characteristics other than small neck diameter were associated with WCS emergence.

Conclusions

WCS is not specific to bioactive coil usage. Small neck diameter was significantly associated with WCS emergence in our series. Further investigations to clarify the predictors of WCS will contribute to progress of aneurysmal embolization.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Byun HS, Rhee K (2004) CFD modeling of blood flow following coil embolization of aneurysms. Med Eng Phys 26:755–761

    Article  PubMed  Google Scholar 

  2. Gonzalez NR, Patel AB, Murayama Y, Viñuela F (2005) Angiographic evidence of aneurysm neck healing following endovascular treatment with bioactive coils. AJNR Am J Neuroradiol 26:912–914

    PubMed  Google Scholar 

  3. Kawakami O, Miyamoto S, Hatano T, Yamada K, Hashimoto N, Tabata Y (2005) Accelerated embolization healing of aneurysms by polyethylene terephthalate coils seeded with autologous fibroblasts. Neurosurgery 56:1075–1081

    PubMed  Google Scholar 

  4. Li MH, Gao BL, Fang C, Gu BX, Cheng YS, Wang W, Scotti G (2006) Angiographic follow-up of cerebral aneurysms treated with Guglielmi detachable coils: an analysis of 162 cases with 173 aneurysms. AJNR Am J Neuroradiol 27:1107–1112

    PubMed  Google Scholar 

  5. Murayama Y, Tateshima S, Gonzalez NR, Vinuela F (2003) Matrix and bioabsorbable polymeric coils accelerate healing of intracranial aneurysms: long-term experimental study. Stroke 34:2031–2037

    Article  PubMed  Google Scholar 

  6. Murayama Y, Vinuela F, Tateshima S, Gonzalez NR, Song JK, Mahdavieh H, Iruela-Arispe L (2002) Cellular responses of bioabsorbable polymeric material and Guglielmi detachable coil in experimental aneurysms. Stroke 33:1120–1128

    Article  PubMed  Google Scholar 

  7. Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambeert A, Lamoureux J, Chagnon M, Roy D (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403

    Article  PubMed  Google Scholar 

  8. Roth C, Struffert T, Grunwald IQ, Romeike BF, Krick C, Papanaqiotou P, Krampe P, Reith W (2008) Long-term results with Matrix coils vs. GDC: an angiographic and histopathological comparison. Neuroradiology 50:693–699

    Article  CAS  PubMed  Google Scholar 

  9. Roy D, Milot G, Raymond J (2001) Endovascular treatment of unruptured aneurysms. Stroke 32:1998–2004

    Article  CAS  PubMed  Google Scholar 

  10. Songsaeng D, Geibprasert S, ter Brugge KG, Willinsky R, Tymianski M, Krings T (2011) Impact of individual intracranial arterial aneurysm morphology on initial obliteration and recurrence rates of endovascular treatments: a multivariate analysis. J Neurosurg 114:994–1002

    Article  PubMed  Google Scholar 

  11. Turk AS, Luty CM, Carr-Brendel V, Polyakov I, Consigny D, Grinde J, Mukherjee R, Strother CM (2007) Angiographic and histological comparison of canine bifurcation aneurysms treated with first generation matrix and standard GDC coils. Neuroradiology 50:57–65

    Article  PubMed  Google Scholar 

  12. White PM, Raymond J (2009) Endovascular coiling of cerebral aneurysms using "bioactive" or coated-coil technologies: a systematic review of the literature. AJNR Am J Neuroradiol 30:219–226

    Article  CAS  PubMed  Google Scholar 

Download references

Conflicts of Interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yuji Matsumaru.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kiyofuji, S., Matsumaru, Y., Tsuruta, W. et al. Emergence of the white-collar sign after coil embolization of cerebral aneurysms. Acta Neurochir 156, 11–16 (2014). https://doi.org/10.1007/s00701-013-1898-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00701-013-1898-3

Keywords

Navigation