Abstract
The current study intended to evaluate two types of biorecognition element (BRE), namely recombinant antibody fragments and M13 bacteriophage-displayed antibody fragments, where protein L and electrostatic interactions were used to respectively conjugated antibodies and bacteriophages on AuNPs. The functionalization process was examined by DLS to monitor the changes in the size and zeta potential. The formation of the BRE-G17-Gly immunological complexes was manifested by aggregation (confirmed by FE-SEM) and color change from red to dark blue visible to the naked eye. Local refractive index variations of functionalized AuNPs were monitored by a UV − vis spectrophotometer, showing increasing size and decreasing zeta potential in all stages. The calibration plot was developed in the concentration range 1–5 µg/mL and the limit of detection (LOD) was 1 µg/mL. The LSRP nanobiosensor in combination with the phage-based BRE was an affordable and simple approach, as it was able to eliminate the time-consuming and costly step of extracting antibodies. Contrary to the traditional immunoassays, this method does not require additional amplification, e.g., enzymatic, to read the result. The proposed LSPR nanobiosensor model can be adapted to detect a wide range of pathogens, viruses, and biomarkers in the shortest possible time.
Graphical abstract
Similar content being viewed by others
Data availability
Data sharing is not applicable to this article as all data created or analyzed in this study are detailed in the results section in the manuscript.
References
Li P, Lee G-H, Kim SY, Kwon SY, Kim H-R, Park S (2021) From diagnosis to treatment: recent advances in patient-friendly biosensors and implantable devices. ACS Nano 15(2):1960–2004
Metkar SK, Girigoswami K (2019) Diagnostic biosensors in medicine–a review. Biocatal Agric Biotechnol 17:271–283
Mejía-Salazar J, Oliveira ON Jr (2018) Plasmonic biosensing: focus review. Chem Rev 118(20):10617–10625
Shpacovitch V, Hergenröder R (2020) Surface plasmon resonance (SPR)-based biosensors as instruments with high versatility and sensitivity. Sensors 20(11):3010
Souto DE, Volpe J, Gonçalves CdC, Ramos CH, Kubota LT (2019) A brief review on the strategy of developing SPR-based biosensors for application to the diagnosis of neglected tropical diseases. Talanta 205:120122
Söylemez C (2020) Design of localized surface plasmon resonance (LSPR) based biosensor for detecting a potential cancer biomarker. Doctoral dissertation, Izmir Institute of Technology, Turkey
Kumari S, Saini SM (2021) Plasmonic nanostructures for sensor technology-a review. IOP Conf Ser Mater Sci Eng 1120:012009
Chowdhury AD, Nasrin F, Gangopadhyay R, Ganganboina AB, Takemura K, Kozaki I et al (2020) Controlling distance, size and concentration of nanoconjugates for optimized LSPR based biosensors. Biosens Bioelectron 170:112657
Mauriz E (2020) Clinical applications of visual plasmonic colorimetric sensing. Sensors 20(21):6214
Justino CI, Freitas AC, Pereira R, Duarte AC, Santos TAR (2015) Recent developments in recognition elements for chemical sensors and biosensors. TrAC Trends Anal Chem 68:2–17
Singh S, Kumar V, Dhanjal DS, Datta S, Prasad R, Singh J (2020) Biological biosensors for monitoring and diagnosis. In: Microbial biotechnology: basic research and applications. Springer, Singapore, pp 317
Ma H, O’kennedy R (2017) Recombinant antibody fragment production. Methods 116:23–33
Gonzalez-Sapienza G, Rossotti MA, Tabares-da RS (2017) Single-domain antibodies as versatile affinity reagents for analytical and diagnostic applications. Front Immunol 8:977
Gupta SK, Shukla P (2017) Microbial platform technology for recombinant antibody fragment production: a review. Crit Rev Microbiol 43(1):31–42
Fahimi F, Sarhaddi S, Fouladi M, Samadi N, Sadeghi J, Golchin A et al (2018) Phage display-derived antibody fragments against conserved regions of VacA toxin of Helicobacter pylori. Appl Microbiol Biotechnol 102(16):6899–6913
Jalilzadeh-Razin S, Mantegi M, Tohidkia MR, Pazhang Y, Pourseif MM, Barar J et al (2019) Phage antibody library screening for the selection of novel high-affinity human single-chain variable fragment against gastrin receptor: an in silico and in vitro study. DARU J Pharm Sci 27(1):21–34
Kumar R, Parray HA, Shrivastava T, Sinha S, Luthra K (2019) Phage display antibody libraries: a robust approach for generation of recombinant human monoclonal antibodies. Int J Biol Macromol 135:907–918
Park M (2020) Surface display technology for biosensor applications: a review. Sensors 20(10):2775
Rehfeld JF (2017) The long goodbye to glycine-extended peptide hormones. Int J Endocr Oncol 4(4):147
Sadighbayan D, Tohidkia MR, Mehdipour T, Hasanzadeh M, Khosroushahi AY (2020) Bio-assay of the non-amidated progastrin-derived peptide (G17-Gly) using the tailor-made recombinant antibody fragment and phage display method: a biomedical analysis. Anal Methods 12(21):2735–2746
Dong J, Carpinone PL, Pyrgiotakis G, Demokritou P, Moudgil BM (2020) Synthesis of precision gold nanoparticles using Turkevich method. Kona Powder Part J 37:224–232
Rezaei Z, Ranjbar B (2017) Ultra-sensitive, rapid gold nanoparticle-quantum dot plexcitonic self-assembled aptamer-based nanobiosensor for the detection of human cardiac troponin I. Eng Life Sci 17(2):165–174
Khajeh S, Tohidkia MR, Aghanejad A, Mehdipour T, Fathi F, Omidi Y (2018) Phage display selection of fully human antibody fragments to inhibit growth-promoting effects of glycine-extended gastrin 17 on human colorectal cancer cells. Artif Cells Nanomed Biotechnol 46(sup2):1082–1090
Belicky S, Damborsky P, Zapatero-Rodríguez J, O’Kennedy R, Tkac J (2017) Full-length antibodies versus single-chain antibody fragments for a selective impedimetric lectin-based glycoprofiling of prostate specific antigen. Electrochim Acta 246:399–405
Liu Y, Lin M, Zhang X, Hu X, Lin J, Hao J et al (2017) Development of competitive ELISA for the detection of bovine serum albumin using single-chain variable fragments. Anal Biochem 525:89–91
Bakhmachuk A, Gorbatiuk O, Rachkov A, Soldatkin A (2020) Study on efficiency of oriented immobilization of antibodies on the SPR sensor surface using Staphylococcal protein A or its recombinant analogue. Biopolymers Cell 36(4):271
Chung J, Park J, Bernhardt R, Pyun J (2006) Immunosensor with a controlled orientation of antibodies by using NeutrAvidin–protein A complex at immunoaffinity layer. J Biotechnol 126(3):325–333
Rodrigo G, Gruvegård M, Van Alstine JM (2015) Antibody fragments and their purification by protein L affinity chromatography. Antibodies 4(3):259–277
Passaretti P, Sun Y, Dafforn TR, Oppenheimer PG (2020) Determination and characterisation of the surface charge properties of the bacteriophage M13 to assist bio-nanoengineering. RSC Adv 10(42):25385–25392
Lee HE, Lee HK, Chang H, Ahn HY, Erdene N, Lee HY et al (2014) Virus templated gold nanocube chain for SERS nanoprobe. Small 10(15):3007–3011
Morales MA, Halpern JM (2018) Guide to selecting a biorecognition element for biosensors. Bioconjug Chem 29(10):3231–3239
Crivianu-Gaita V, Thompson M (2016) Aptamers, antibody scFv, and antibody Fab’fragments: an overview and comparison of three of the most versatile biosensor biorecognition elements. Biosens Bioelectron 85:32–45
AliakbarAhovan Z, Hashemi A, De Plano LM, Gholipourmalekabadi M, Seifalian A (2020) Bacteriophage based biosensors: trends, outcomes and challenges. Nanomaterials 10(3):501
Acknowledgements
This project is part of an M.Sc. thesis conducted at Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran, and was supported by the Tabriz University of Medical Sciences.
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Ethics approval
Ethics approval was not required for this research.
Research involving human participants and/or animals
Not applicable.
Informed consent
Not applicable.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Fattahi, Z., Tohidkia, M.R. & Yari Khosroushahi, A. Phage display-derived immunorecognition elements LSPR nanobiosensor for peptide hormone glycine-extended gastrin 17 detection. Microchim Acta 189, 48 (2022). https://doi.org/10.1007/s00604-021-05159-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00604-021-05159-4