Abstract
A rapid and automated method was developed for the determination of bacterial contamination and using Escherichia coli as a model microorganism. The method involves the use of a sensor connected to a flow injection (FI) system. The sample is introduced through a flow injection system into a piezoelectric quartz crystal (PQC) flow-cell. The resulting change of the resonance frequency is related to the bacterial contamination in the sample. The parameters associated with the flow system and the conditions for introducing the sample culture were optimized. Calibration curves are linear in the range from 3.2 × 107 to 3.2 × 109 cfu per mL-1, with a correlation coefficient of 0.997. The reproducibility was between 3.1 and 7.6%, and the detection limit is 1.1 × 107 cfu per mL-1. The method allowed the determination of bacterial contamination in residual water and in samples of milk and chicken stock within 5 h, while the conventional plate count method requires 24 to 48 h. The results obtained by these two methods are in good agreement.
Similar content being viewed by others
References
De Boer E (1998) Update on media isolation of Enterobacteriaceae from foods. J Food Microbiol 45:43–55
Standard methods for the examination of water and wastewater, 20th ed., American Public Heath Association (APHA), American water works association, Water Environment Federation, Washington, DC, 1998.
Shana ZA, Zong H, Josse F, Jeutter DC (1994) Analysis of electrical equivalent circuit of quartz crystal resonator loaded with viscous conductive liquids. J Electroanal Chem 379:21–33
Valdés MG, Valdés González AC, García Calzón JA, Díaz-García ME (2009) Analytical nanotechnology for food analysis. Microchim Acta 166:1–19
Deisingh AK, Thompson M (2002) Detection of toxigenic and infectious bacteria. Analyst 127:567–581
Kalasinsky VF (1996) Biomedical applications of infrared and Raman microscopy. Appl Spectrosc Rev 31:193–249
Janshoff A, Steinem C (2001) Quartz Crystal Microbalance for Bioanalytical. Applications Sens Update 9:313–354
Spangler BD, Tyler BJ (1999) Capture agents for a quartz crystal microbalance-continuous flow biosensor: functionalized self-assembled monolayers on gold. Anal Chim Acta 399:51–62
Manganiello L, Ríos A, Valcárcel M, Ligero A, Tena T (2000) Automatic determination of fat in milk by use of a flow injection system with a piezoelectric detector. Anal Chim Acta 406:309–315
He F, Geng Q, Zhu W, Nie L, Yao S, Meifeng C (1994) Rapid detection of Escherichia coli using a separated electrode piezoelectric crystal sensor. Anal Chim Acta 289:313–319
Chang B-W, Hsu Y-M, Chang H-C (2000) An improving method for determination of Escherichia coli population based on multi-channel series piezoelectric quartz crystal system. Sensors and Actuators B 65:105–107
Kim N, Park I-S (2003) Application of a flow-type antibody sensor to the detection of Escherichia coli in various foods. Biosens Bioelectron 18:1101–1107
Wu VCH, Chenb S-H, Lin C-S (2007) Real-time detection of Escherichia coli O157:H7 sequences using a circulating-flow system of quartz crystal microbalance. Biosens Bioelectron 22:2967–2975
Chen K, Le D, Zhang H, Nie L, Yao S (1996) Model of quartz crystal microbe growth sensor and its application to estimation of microbial populations in mineral waters. Anal Chim Acta 329:83–89
Bao L, Tan H, Deng L, Wei W (1998) A new piezoelectric response model for population growth of bacteria. Talanta 47:267–273
Detzel AJ, Campbell GA, Mutharasan R (2006) Rapid assessment of E. coli by growth rate on piezoelectric-excited millimetre-sized cantilever sensor. Sens Actuators B 117:58–64
Shen Z, Huang M, Xiao C, Zhang Y, Wang PG (2007) Nonlabeled Quartz Crystal Microbalance Biosensor for Bacterial Detection Using Carbohydrate and Lectin Recognitions. Anal Chem 79:2312–2319
Sauerbrey G (1959) Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung. Z Phys 155:206–210
Hengerer A, Decker J, Prohaska E, Hauck S, Kößlinger C, Wolf H (1999) Determination of phage antibody affinities to antigen by a microbalance sensor system. Biosens Bioelectron 14:139–144
Okahata Y, Niikura K, Sugiura Y, Sawada M, Morii T (1998) Kinetic studies of sequence-specific binding of GCN4-bZIP peptides to DNA strands immobilized on a 27-MHz quartz-crystal microbalance. Biochemistry 37:5666–5672
Bao L, Deng L, Nie L, Yao S, Wei W (1996) Determination of microorganisms with a quartz crystal microbalance sensor. Anal Chim Acta 319:97–101
Boujday S, Briandet R, Salmain M, Herry J-M, Marnet P-G, Gautier M, Pradier C-M (2008) Detection of pathogenic Staphylococcus aureus bacteria by gold based immunosensors. Microchim Acta 163:203–209
Fung YS, Wong CCW, Choy JTS, Sze KL (2008) Determination of sulphate in water by flow-injection analysis with electrode-separated piezoelectric quartz crystal sensor. Sens Actuators B 130:551–560
Mo Z, Long X, Zhang M (1999) Piezoelectric detection of ion pairs between sulphonate and catecholamines for flow injection analysis of pharmaceutical preparations. Talanta 48:643–648
Zougagh M, Ríos A, Valcárcel M (2005) Automatic selective determination of caffeine in coffee and tea samples by using a supported liquid membrane-modified piezoelectric flow sensor with molecularly imprinted polymer. Anal Chim Acta 539:117–124
Zougagh M, Ríos A, Valcárcel M (2005) Direct determination of total carbonate salts in soil samples by continuous-flow piezoelectric detection. Talanta 65:29–35
Palenzuela B, Simonet BM, Ríos A, Valcárcel M (2005) Determination of free and total sulphur in wine by use of an amalgamated piezoelectric sensor. Anal Chim Acta 535:65–72
Ingraham JL, Ingraham CA (1997) Introducción a la Microbiología. Ed. Reverté Chap. III Pag. 69.
Acknowledgements
Financial support from the Spanish Ministry of Innovation, Science and Technology (Project CTQ2010-15027) and the Junta de Comunidades of Castilla-La Mancha (PAC08-0015-0722) are gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
ESM 1
(DOC 3976 kb)
Rights and permissions
About this article
Cite this article
Plata, M.R., Contento, A.M. & Ríos, Á. Simplified determination of bacterial contamination by Escherichia coli using a flow injection system with piezoelectric detection. Microchim Acta 172, 447–454 (2011). https://doi.org/10.1007/s00604-010-0504-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-010-0504-0