Abstract
The performance of yttrium as internal standard was investigated when aspirating digested samples or alternatively slurries of certified plant reference materials. The stability of the yttrium signal used for analyte signal normalization was examined for three ionic emission lines of yttrium. The results showed that the use of yttrium was beneficial; however for the slurry sample introduction technique it was not equivalently efficient in terms of overall recovery. In this case, the employment of a cyclonic instead of a double-pass spray chamber in combination with yttrium internal standardization leads to quantitative recoveries of the analytes.
Similar content being viewed by others
References
Bruno P, Caselli M, Curri ML, Genga A, Striccoli R, Traini A (2000) Chemical characterisation of ancient pottery from south of Italy by inductively coupled plasma atomic emission spectroscopy (ICP-AES) statistical multivariate analysis of data. Anal Chim Acta 410:193
Griffiths ML, Svozil D, Worsfold PJ, Denham S, Hywel Evans E (2000) Comparison of traditional and multivariate calibration techniques applied to complex matrices using inductively coupled plasma atomic emission spectroscopy. J Anal At Spectrom 15:967
Masson P (1999) Matrix effects during trace element analysis in plant samples by inductively coupled plasma atomic emission spectrometry with axial view configuration and pneumatic nebulizer. Spectrochim Acta B 54:603
Kanicky V, Otruba V, Mermet JM (1998) Use of internal standardization to compensate for a wide range of absorbance in the analysis of glasses by UV laser ablation inductively coupled plasma atomic emission spectrometry. Appl Spectrosc 52:638
Dubuisson C, Poussel E, Mermet JM (1998) Comparison of ionic line-based internal standardization with axially and radially viewed inductively coupled plasma atomic emission spectrometry to compensate for sodium effects on accuracy. J Anal At Spectrom 13:1265
De Sousa RA, Silva JSJ, Baccan N, Cadore S (2005) Determination of metals in bottled coconut water using an inductively coupled plasma optical emission spectrometer. J Food Comp Anal 18:399
Marucco A, Marcolli C, Magarini R (1999) ICP-OES analysis of gold alloys using yttrium or indium as internal standard. Atom Spectrosc 20:134
Kanicky V, Mermet JM (1999) Use of a single calibration graph for the determination of major elements in geological materials by laser ablation inductively coupled plasma atomic emission spectrometry with added internal standards. Fresenius J Anal Chem 363:294
Office of Public Health Science (2002) CLG-TM 4.01: detection of Tl, As and Hg using ICP-AES. Office of Public Health Science, US Dept. of Agriculture
NIOSH (1994) Method 8005: elements in blood or tissue. NIOSH manual of analytical methods, 4th edn. NIOSH
Caravaglia RN, Rebagliati RJ, Roberti MJ, Batistoni DA (2002) Matrix effects in the analysis of biological matrices by axial view inductively coupled plasma optical emission spectrometry. Spectrochim Acta B 57:1925
Salin ED, Antler M, Bort G (2004) Evaluation of the simultaneous use of standard additions and internal standards calibration techniques for inductively coupled plasma mass spectrometry. J Anal At Spectrom 19:1498
Ivaldi PC, Tyson JF (1996) Real-time internal standardization with an axially-viewed inductively coupled plasma for optical emission spectrometry. Spectrochim Acta B 51:1443
Mokgalaka NS, McCrindle RI, Botha BM (2004) Multielement analysis of tea leaves by inductively coupled plasma optical emission spectrometry using slurry nebulisation. J Anal At Spectrom 19:1375
Matusiewicz H, Golik B (2004) Determination of major and trace elements in biological materials by microwave induced plasma optical emission spectrometry (MIP-OES) following tetramethylammonium hydroxide (TMAH) solubilization. Microchem J 76:23
Lobinski R, van Borm W, Broekaert JAC, Tschopel P, Tolg G (1992) Optimization of slurry nebulization inductively-coupled plasma atomic emission spectrometry for the analysis of ZrO2-powder. Fresenius J Anal Chem 342:563
Matusiewicz H, Golik B (2004) Simultaneous determination of macro and trace elements in biological reference materials by microwave induced plasma optical emission spectrometry with slurry sample introduction. Spectrochim Acta Part B 59:749
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zachariadis, G.A., Sarafidou, P.C. Internal standardization with yttrium spectral lines using axial-viewing inductively coupled plasma atomic emission spectrometry for plant certified reference materials analysis. Microchim Acta 166, 77–81 (2009). https://doi.org/10.1007/s00604-009-0168-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-009-0168-9