Abstract.
An analytical method using inductively coupled plasma atomic emission spectrometry (ICP-AES) for rapid simultaneous determination of seven heavy metals (Cd, Co, Cr, Cu, Mn, Ni and Pb) in human blood fractions, like plasma, cells fraction and whole blood, is performed. The optimum wavelength was selected using as criterions the sensitivity, the linearity and recovery of aqueous standard solutions. The pretreatment of the sample, the centrifugal conditions, the necessity of digestion and the dilution of the digests were also studied. For plasma it was possible to avoid digestion of the sample, but for cells fractions and whole blood the digestion is necessary. The samples were acid-digested by HNO3 in closed Teflon tubes under high temperature and pressure conditions and were diluted before injection into ICP-AES. Also, optimization of the inductively coupled plasma conditions like nebulizer argon flow rate, sample flow rate and power of radio frequency was performed for each analyte. Finally, the effect of the type of the employed calibration technique on the total variation of the method was examined. Calibration using the standard addition technique was proved more accurate for the determination in terms of analyte recovery. The sensitivity and recovery (Cd 99%, Co 101%, Cr 100%, Cu 99%, Mn 101%, Ni 100% and Pb 97%) of the developed method are presented for all examined blood fractions.
Similar content being viewed by others
References
H Haraguchi (1999) ArticleTitleMultielement profiling analyses of biological, geochemical, and environmental samples as studied by analytical atomic spectrometry B Chem Soc Jpn 72 1163 Occurrence Handle10.1246/bcsj.72.1163 Occurrence Handle1:CAS:528:DyaK1MXjs1GnsbY%3D
K Pomazal C Prohaska I Steffan (2002) ArticleTitleHydrophobic interaction chromatographic separation of proteins in human blood fractions hyphenated to atomic spectrometry as detector of essential elements J Chromat A 960 143 Occurrence Handle10.1016/S0021-9673(02)00334-5 Occurrence Handle1:CAS:528:DC%2BD38XksFKgs7g%3D
N Todorovska I Karadjova T Stafilov (2002) ArticleTitleETAAS determination of nickel in serum and urine Anal Bioanal Chem 373 310 Occurrence Handle10.1007/s00216-002-1328-5 Occurrence Handle1:CAS:528:DC%2BD38XltVehs7Y%3D
A Alimonti F Petrucci B Santucci A Cristaudo S Caroli (1995) ArticleTitleDetermination of chromium and nickel in human blood by means of inductively coupled plasma mass spectrometry Anal Chim Acta 306 35 Occurrence Handle10.1016/0003-2670(94)00620-2 Occurrence Handle1:CAS:528:DyaK2MXltVynsLk%3D
A Aitio A Aro J Jarvisalo H Vario (1991) Trace elements in health and disease The Royal Society of Chemistry Cambridge
M J Kendrick M T May M J Plishka K D Robinson (1992) Metals in biological systems Ellis Horwood Limited England 139
E Barany I A Bergdahl A Schutz S Skerfving A Oskarsson (1997) ArticleTitleInductively coupled plasma mass spectrometry for direct multi-element analysis of diluted human blood and serum J Anal At Spectrom 12 1005 Occurrence Handle10.1039/a700904f Occurrence Handle1:CAS:528:DyaK2sXmtFWrsL4%3D
J Versieck R Cornelis (1989) Trace elements in human plasma and serum CRC Press Boca Raton
R N Garavaglia R J Rebagliati M J Roberti D A Batistoni (2002) ArticleTitleMatrix effects in the analysis of biological matrices by axial view inductively coupled plasma optical emission spectrometry Spectrochim Acta Part B 57 1925 Occurrence Handle10.1016/S0584-8547(02)00182-9
I Rodushkin F Odman S Branth (1999) ArticleTitleMultielement analysis of whole blood by high resolution inductively coupled plasma mass spectrometry Fresen J Anal Chem 364 338 Occurrence Handle10.1007/s002160051346 Occurrence Handle1:CAS:528:DyaK1MXkt1Kjs7w%3D
I Rodushkin F Odman R Olofsson M D Axelsson (2000) ArticleTitleDetermination of 60 elements in whole blood by sector field inductively coupled plasma mass spectrometry J Anal At Spectrom 15 937 Occurrence Handle10.1039/b003561k Occurrence Handle1:CAS:528:DC%2BD3cXltF2ntbs%3D
R Rahil-Khazen H Henriksen B J Bolann R J Ulvik (2000) ArticleTitleValidation of inductively coupled plasma atomic emission spectrometry technique (ICP-AES) for multi-element analysis of trace elements in human serum Scand J Clin Lab Invest 60 677 Occurrence Handle10.1080/00365510050216402 Occurrence Handle1:CAS:528:DC%2BD3MXht1Wjt7s%3D
K Pomazal C Prohaska I Steffan G Reich J F K Huber (1999) ArticleTitleDetermination of Cu, Fe, Mn, and Zn in blood fractions by SEC-HPLC-ICP-AES coupling Analyst 124 657 Occurrence Handle10.1039/a809688k Occurrence Handle1:CAS:528:DyaK1MXivVSmtLk%3D
J P Goulle L Mahieu J Castermant N Neveu L Bonneau G Laine D Bouige C Lacroix (2005) ArticleTitleMetal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hair – reference values Forensic Sci Int 153 39 Occurrence Handle10.1016/j.forsciint.2005.04.020 Occurrence Handle1:CAS:528:DC%2BD2MXmsVWltrk%3D
C Prohaska K Pomazal I Steffan (2000) ArticleTitleETAAS method for the determination of Cd, Cr, Cu, Mn and Se in blood fractions and whole blood Fresen J Anal Chem 368 627 Occurrence Handle10.1007/s002160000520 Occurrence Handle1:CAS:528:DC%2BD3cXns1eqtbk%3D
B Bocca A Alimonti G Forte F Petrucci C Pirola O Senofonte N Violante (2003) ArticleTitleHigh-throughput microwave-digestion procedures to monitor neurotoxic elements in body fluids by means of inductively coupled plasma mass spectrometry Anal Bioanal Chem 377 65 Occurrence Handle10.1007/s00216-003-2029-4 Occurrence Handle1:CAS:528:DC%2BD3sXms1SnsrY%3D
Q Z Bian P Jacob H Berndt K Niemax (2005) ArticleTitleOnline flow digestion of biological and environmental samples for inductively coupled plasma-optical emission spectroscopy (ICP-OES) Anal Chim Acta 538 323 Occurrence Handle10.1016/j.aca.2005.01.074 Occurrence Handle1:CAS:528:DC%2BD2MXjs1Sqsbs%3D
J Riondato F Venhaecke L Moens R Dams (1997) ArticleTitleDetermination of trace and ultratrace elements in human serum with a double focusing magnetic sector inductively coupled plasma mass spectrometer J Anal At Spectrom 12 933 Occurrence Handle10.1039/a701652b Occurrence Handle1:CAS:528:DyaK2sXmtFWku7c%3D
Author information
Authors and Affiliations
Corresponding author
Additional information
Correspondence: George A. Zachariadis, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124, Greece
Rights and permissions
About this article
Cite this article
Daftsis, E., Zachariadis, G. Analytical performance of a multi-element ICP-AES method for Cd, Co, Cr, Cu, Mn, Ni and Pb determination in blood fraction samples. Microchim Acta 160, 405–411 (2008). https://doi.org/10.1007/s00604-007-0791-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-007-0791-2